Effect of Polishing Systems on Mechanical Properties of Emax Press Restorations

Marwah Hussein Abdulsattar, Sara Abdulbasit Turki, Zahraa Nazar Alwahab
{"title":"Effect of Polishing Systems on Mechanical Properties of Emax Press Restorations","authors":"Marwah Hussein Abdulsattar, Sara Abdulbasit Turki, Zahraa Nazar Alwahab","doi":"10.25130/tjds.11.2.7","DOIUrl":null,"url":null,"abstract":"This study aimed to evaluate the impact of surface treatment (polishing, polishing with diamond paste and glazing) on the Vickers microhardness of pressable ceramics IPS Emax porcelain in comparison with non-treated surface. Materials and Methods: Forty disc shaped samples of baseplate wax with 10 mm diameter and 2 mm thickness have been prepared. They were invested and lost wax technique was performed to fabricate the pressable ceramic. Following pressing, they were divided randomly into four groups (n=10): Group A: no surface treatment, Group B: glazing (paste, HT, Ivoclar,Vivadent, Germany) glazing (paste, HT, Ivoclar,Vivadent, Germany), Group C : polishing with burs (DIAPRO TWIST,EVE, GmbH, Germany) and diamond paste (All in one, RENFERT, GmbH, Germany), and Group D: polishing with burs (DIAPRO TWIST,EVE, GmbH, Germany). For all specimens, the Vickers hardness number (VHN) was determined using a digital tester. Vickers hardness was used in this analysis due to the small specimen size and multiple compositions. Each specimen was put on the device's stage, the Vickers indenter was then lowered slowly until it came into contact with the polished surface of the specimen. Results: The highest Vickers Hardness Number was for polishing with burs and diamond paste and polishing with burs, while the lowest Vickers Hardness Number was for control group. One-way ANOVA test showed a high significant difference at P < .000. LSD test reviled there was non-significant difference between polishing with burs and polishing with burs and diamond paste. Conclusions: Within the limitation of the present study, it can be concluded that, polishing can considered as an effective method as glazing to improve surface hardness of pressable ceramic, and polishing with or without diamond paste can be an effective method to improve surface hardness.","PeriodicalId":512116,"journal":{"name":"Tikrit Journal for Dental Sciences","volume":"87 17","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tikrit Journal for Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25130/tjds.11.2.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to evaluate the impact of surface treatment (polishing, polishing with diamond paste and glazing) on the Vickers microhardness of pressable ceramics IPS Emax porcelain in comparison with non-treated surface. Materials and Methods: Forty disc shaped samples of baseplate wax with 10 mm diameter and 2 mm thickness have been prepared. They were invested and lost wax technique was performed to fabricate the pressable ceramic. Following pressing, they were divided randomly into four groups (n=10): Group A: no surface treatment, Group B: glazing (paste, HT, Ivoclar,Vivadent, Germany) glazing (paste, HT, Ivoclar,Vivadent, Germany), Group C : polishing with burs (DIAPRO TWIST,EVE, GmbH, Germany) and diamond paste (All in one, RENFERT, GmbH, Germany), and Group D: polishing with burs (DIAPRO TWIST,EVE, GmbH, Germany). For all specimens, the Vickers hardness number (VHN) was determined using a digital tester. Vickers hardness was used in this analysis due to the small specimen size and multiple compositions. Each specimen was put on the device's stage, the Vickers indenter was then lowered slowly until it came into contact with the polished surface of the specimen. Results: The highest Vickers Hardness Number was for polishing with burs and diamond paste and polishing with burs, while the lowest Vickers Hardness Number was for control group. One-way ANOVA test showed a high significant difference at P < .000. LSD test reviled there was non-significant difference between polishing with burs and polishing with burs and diamond paste. Conclusions: Within the limitation of the present study, it can be concluded that, polishing can considered as an effective method as glazing to improve surface hardness of pressable ceramic, and polishing with or without diamond paste can be an effective method to improve surface hardness.
抛光系统对 Emax 压力修复体机械性能的影响
本研究旨在评估与未处理表面相比,表面处理(抛光、用金刚石膏抛光和上釉)对可压陶瓷 IPS Emax 瓷的维氏硬度的影响。材料和方法:制备了 40 个直径为 10 毫米、厚度为 2 毫米的圆盘状底板蜡样。对它们进行投资,并采用失蜡技术制作可压陶瓷。压制后,这些样品被随机分为四组(n=10):A 组:无表面处理;B 组:上釉(粘贴,HT,德国 Ivoclar,Vivadent);C 组:用车针(DIAPRO TWIST,EVE,GmbH,德国)和金刚石粘贴(All in one,RENFERT,GmbH,德国)抛光;D 组:用车针(DIAPRO TWIST,EVE,GmbH,德国)抛光。所有试样的维氏硬度数(VHN)都是用数字测试仪测定的。由于试样尺寸较小,且具有多种成分,因此在本分析中使用了维氏硬度。将每个试样放在仪器的平台上,然后缓慢降低维氏硬度计,直到其接触到试样的抛光表面。结果:用车针和金刚石膏抛光以及用车针抛光的维氏硬度数最高,而对照组的维氏硬度数最低。单因素方差分析检验表明,P < .000 时差异显著。LSD 检验表明,用车针抛光与用车针和金刚石膏抛光之间的差异不显著。结论在本研究的局限性范围内,可以得出结论:抛光可被视为提高可压陶瓷表面硬度的一种有效方法,而使用或不使用金刚石膏抛光也是提高表面硬度的一种有效方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信