N. Ogino, M. Arimoto, T. Sawano, D. Yonetoku, Hsien-chieh Shen, Takanori Sakamoto, J. Hiraga, Y. Yatsu, Tatehiro Mihara
{"title":"High-speed readout system of X-ray CMOS image sensor for time domain astronomy","authors":"N. Ogino, M. Arimoto, T. Sawano, D. Yonetoku, Hsien-chieh Shen, Takanori Sakamoto, J. Hiraga, Y. Yatsu, Tatehiro Mihara","doi":"10.1088/1748-0221/19/01/C01006","DOIUrl":null,"url":null,"abstract":"We developed an FPGA-based high-speed readout system for a complementary metal-oxide-semiconductor (CMOS) image sensor to observe soft X-ray transients in future satellite missions, such as HiZ-GUNDAM. Our previous research revealed that the CMOS image sensor has low-energy X-ray detection capability (0.4–4 keV) and strong radiation tolerance, which satisfies the requirements of the HiZ-GUNDAM mission. However, CMOS sensors typically have small pixel sizes (e.g., ∼10 µm), resulting in large volumes of image data. GSENSE400BSI has 2048×2048 pixels, producing 6 Mbyte per frame. These large volumes of observed raw image data cannot be stored in a satellite bus system with a limited storage size. Therefore, only X-ray photon events must be extracted from the raw image data. Furthermore, the readout time of CMOS image sensors is approximately ten times faster than that of typical X-ray CCDs, requiring faster event extraction on a timescale of ∼0.1 s. To address these issues, we have developed an FPGA-based image signal processing system capable of high-speed X-ray event extraction onboard without storing raw image data. The developed compact system enabled mounting on a CubeSat mission, facilitating early in-orbit operation demonstration. Here, we present the design and results of the performance evaluation tests of the proposed FPGA-based readout system. Utilizing X-ray irradiation experiments, the results of the X-ray event extraction with the onboard and offline processing methods were consistent, validating the functionality of the proposed system.","PeriodicalId":16184,"journal":{"name":"Journal of Instrumentation","volume":" 3","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Instrumentation","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1748-0221/19/01/C01006","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
We developed an FPGA-based high-speed readout system for a complementary metal-oxide-semiconductor (CMOS) image sensor to observe soft X-ray transients in future satellite missions, such as HiZ-GUNDAM. Our previous research revealed that the CMOS image sensor has low-energy X-ray detection capability (0.4–4 keV) and strong radiation tolerance, which satisfies the requirements of the HiZ-GUNDAM mission. However, CMOS sensors typically have small pixel sizes (e.g., ∼10 µm), resulting in large volumes of image data. GSENSE400BSI has 2048×2048 pixels, producing 6 Mbyte per frame. These large volumes of observed raw image data cannot be stored in a satellite bus system with a limited storage size. Therefore, only X-ray photon events must be extracted from the raw image data. Furthermore, the readout time of CMOS image sensors is approximately ten times faster than that of typical X-ray CCDs, requiring faster event extraction on a timescale of ∼0.1 s. To address these issues, we have developed an FPGA-based image signal processing system capable of high-speed X-ray event extraction onboard without storing raw image data. The developed compact system enabled mounting on a CubeSat mission, facilitating early in-orbit operation demonstration. Here, we present the design and results of the performance evaluation tests of the proposed FPGA-based readout system. Utilizing X-ray irradiation experiments, the results of the X-ray event extraction with the onboard and offline processing methods were consistent, validating the functionality of the proposed system.
期刊介绍:
Journal of Instrumentation (JINST) covers major areas related to concepts and instrumentation in detector physics, accelerator science and associated experimental methods and techniques, theory, modelling and simulations. The main subject areas include.
-Accelerators: concepts, modelling, simulations and sources-
Instrumentation and hardware for accelerators: particles, synchrotron radiation, neutrons-
Detector physics: concepts, processes, methods, modelling and simulations-
Detectors, apparatus and methods for particle, astroparticle, nuclear, atomic, and molecular physics-
Instrumentation and methods for plasma research-
Methods and apparatus for astronomy and astrophysics-
Detectors, methods and apparatus for biomedical applications, life sciences and material research-
Instrumentation and techniques for medical imaging, diagnostics and therapy-
Instrumentation and techniques for dosimetry, monitoring and radiation damage-
Detectors, instrumentation and methods for non-destructive tests (NDT)-
Detector readout concepts, electronics and data acquisition methods-
Algorithms, software and data reduction methods-
Materials and associated technologies, etc.-
Engineering and technical issues.
JINST also includes a section dedicated to technical reports and instrumentation theses.