{"title":"A comparative study between the outcome of using LigaSure® versus suture ligation in thyroid surgery","authors":"Salah Kadhim, Karrar Ibrahim","doi":"10.4103/MJBL.MJBL_434_23","DOIUrl":null,"url":null,"abstract":"Background: Thyroid surgery is one of the most performed operations; with the high vascularity of the thyroid gland and the importance of hemostasis to the surgical outcome, many surgeons have begun to use energy-based devices to perform thyroid surgical procedures, and numerous studies demonstrated the benefit of these devices. The aim was to compare the use of a vessel sealing device (LigaSure) with suture ligation in perioperative time, hypocalcemia, recurrent laryngeal nerve (RLN) damage, blood loss after surgery, hematoma formation, and period of the patient. Materials and Methods: In this study, 81 patients who underwent total thyroidectomy for different diseases, and divided into two groups corresponding to the hemostasis type: vessel sealing devices (LigaSure) group, and suture ligation group, these groups compared regarding operative time; hypocalcemia, RLN injury, blood loss after surgical procedure, hematoma formation, and period of hospital admissions. Results: The duration of surgery was more significant and shorter in the LigaSure® group 66.57 ± 8.93 min than suture ligation group 86.84 ± 17.5 min with P = 0.0001, with bleeding after surgery, was lesser in LigaSure® patients 52.76 ± 22.8 mL than suture ligation group 95.09 ± 39.91 mL with P = 0.0001; other outcomes (postoperative hematoma formation, injury to recurrent laryngeal nerve, hypocalcemia after surgery, and period of hospital admission), and there was no difference between the two groups mentioned above. Conclusion: The role of the LigaSure instrument in thyroidectomy surgery is to decrease the operative time duration and blood loss after surgery, with no effect on the incidence of recurrent laryngeal nerve damage, postoperative low serum calcium level, and hematoma formation.","PeriodicalId":18326,"journal":{"name":"Medical Journal of Babylon","volume":"3 1","pages":"569 - 573"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Journal of Babylon","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/MJBL.MJBL_434_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Thyroid surgery is one of the most performed operations; with the high vascularity of the thyroid gland and the importance of hemostasis to the surgical outcome, many surgeons have begun to use energy-based devices to perform thyroid surgical procedures, and numerous studies demonstrated the benefit of these devices. The aim was to compare the use of a vessel sealing device (LigaSure) with suture ligation in perioperative time, hypocalcemia, recurrent laryngeal nerve (RLN) damage, blood loss after surgery, hematoma formation, and period of the patient. Materials and Methods: In this study, 81 patients who underwent total thyroidectomy for different diseases, and divided into two groups corresponding to the hemostasis type: vessel sealing devices (LigaSure) group, and suture ligation group, these groups compared regarding operative time; hypocalcemia, RLN injury, blood loss after surgical procedure, hematoma formation, and period of hospital admissions. Results: The duration of surgery was more significant and shorter in the LigaSure® group 66.57 ± 8.93 min than suture ligation group 86.84 ± 17.5 min with P = 0.0001, with bleeding after surgery, was lesser in LigaSure® patients 52.76 ± 22.8 mL than suture ligation group 95.09 ± 39.91 mL with P = 0.0001; other outcomes (postoperative hematoma formation, injury to recurrent laryngeal nerve, hypocalcemia after surgery, and period of hospital admission), and there was no difference between the two groups mentioned above. Conclusion: The role of the LigaSure instrument in thyroidectomy surgery is to decrease the operative time duration and blood loss after surgery, with no effect on the incidence of recurrent laryngeal nerve damage, postoperative low serum calcium level, and hematoma formation.
在甲状腺手术中使用 LigaSure® 与缝线结扎的效果比较研究
背景:甲状腺手术是手术量最大的手术之一;由于甲状腺血管丰富,止血对手术效果非常重要,许多外科医生已开始使用基于能量的设备来进行甲状腺手术,许多研究也证明了这些设备的益处。本研究旨在比较使用血管密封装置(LigaSure)与缝合结扎在围手术期时间、低钙血症、喉返神经(RLN)损伤、术后失血量、血肿形成和患者住院时间等方面的差异。材料和方法:本研究选取了 81 例因不同疾病接受甲状腺全切除术的患者,根据止血类型分为两组:血管密封装置(LigaSure)组和缝合结扎组,两组患者在手术时间、低钙血症、喉返神经损伤、术后失血、血肿形成和住院时间等方面进行了比较。结果显示LigaSure® 组的手术时间(66.57 ± 8.93 分钟)比缝合结扎组(86.84 ± 17.5 分钟)显著缩短(P = 0.0001),术后出血量(52.76 ± 22.8 mL)比缝合结扎组(95.09 ± 39.91 mL,P = 0.0001;其他结果(术后血肿形成、喉返神经损伤、术后低钙血症和住院时间),上述两组之间无差异。结论LigaSure 仪器在甲状腺切除手术中的作用是减少手术时间和术后失血量,而对喉返神经损伤、术后低血清钙水平和血肿形成的发生率没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
21
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信