A Novel Influence of Coated and Uncoated Carbon Boron Nitride on Material Removal Rate for Al-Si12Cu Alloy Using CNC Turning

Q4 Materials Science
N. A. W. O. J. ournal, Kasturi Sumanth, Rathinavelu Venkatesh
{"title":"A Novel Influence of Coated and Uncoated Carbon Boron Nitride on Material Removal Rate for Al-Si12Cu Alloy Using CNC Turning","authors":"N. A. W. O. J. ournal, Kasturi Sumanth, Rathinavelu Venkatesh","doi":"10.17756/nwj.2023-s3-036","DOIUrl":null,"url":null,"abstract":"The prime aim of this experimental study is to find the material removal rate (MRR) of CBN (Carbon boron nitride) coated and uncoated insert on Al-Si12Cu alloy via a novel computer numeric controlled (CNC) turning center. Al-Si12Cu alloy of 50 mm diameter and 200 mm length was utilized for this study. The samples (N = 20) are turned by CBN coated insert (experimental group) and the uncoated insert is considered as the control group to machining another 20 samples (N = 20). The weight of Al-Si12Cu alloy on both group samples was measured before and after the turning process via a digital weighing machine followed by MRR was calculated as per ASTM standard with 80% G-power calculation. Based on the experimental test results of MRR for the turned Al-Si12Cu alloy by CBN coated insert showed 2.762 mm 3 /min and 1.781 mm 3 /min were found gives a significant value of 0.001 (p < 0.05). There is a significant difference between the two groups considered. The two-tailed significance value obtained is 0.001 (p < 0.05) which is statistically significant compared to the uncoated insert showing the adequacy of the design matrix and there is a significant difference have been between the two groups. Within the limitations of this experimental study, the Al-Si12Cu alloys were turned via CBN coated insert has played a prominent role in the enhancement of MRR rather than the samples turned by the uncoated insert.","PeriodicalId":36802,"journal":{"name":"NanoWorld Journal","volume":"17 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NanoWorld Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17756/nwj.2023-s3-036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Materials Science","Score":null,"Total":0}
引用次数: 0

Abstract

The prime aim of this experimental study is to find the material removal rate (MRR) of CBN (Carbon boron nitride) coated and uncoated insert on Al-Si12Cu alloy via a novel computer numeric controlled (CNC) turning center. Al-Si12Cu alloy of 50 mm diameter and 200 mm length was utilized for this study. The samples (N = 20) are turned by CBN coated insert (experimental group) and the uncoated insert is considered as the control group to machining another 20 samples (N = 20). The weight of Al-Si12Cu alloy on both group samples was measured before and after the turning process via a digital weighing machine followed by MRR was calculated as per ASTM standard with 80% G-power calculation. Based on the experimental test results of MRR for the turned Al-Si12Cu alloy by CBN coated insert showed 2.762 mm 3 /min and 1.781 mm 3 /min were found gives a significant value of 0.001 (p < 0.05). There is a significant difference between the two groups considered. The two-tailed significance value obtained is 0.001 (p < 0.05) which is statistically significant compared to the uncoated insert showing the adequacy of the design matrix and there is a significant difference have been between the two groups. Within the limitations of this experimental study, the Al-Si12Cu alloys were turned via CBN coated insert has played a prominent role in the enhancement of MRR rather than the samples turned by the uncoated insert.
有涂层和无涂层氮化硼碳对使用 CNC 车削加工 Al-Si12Cu 合金的材料去除率的新影响
本实验研究的主要目的是通过新型计算机数控(CNC)车削中心,找出在 Al-Si12Cu 合金上涂覆和未涂覆 CBN(氮化硼)刀片的材料去除率(MRR)。本研究使用了直径 50 毫米、长度 200 毫米的 Al-Si12Cu 合金。使用 CBN 涂层刀片车削样品(实验组)(N = 20),未涂层刀片作为对照组,加工另外 20 个样品(N = 20)。两组样品在车削前后都通过数字称重仪测量了 Al-Si12Cu 合金的重量,然后按照 ASTM 标准计算了 MRR,并计算了 80% 的 G 功率。根据 CBN 涂层刀片车削 Al-Si12Cu 合金的 MRR 实验测试结果,发现 2.762 mm 3 /min 和 1.781 mm 3 /min 的显著值为 0.001 (p < 0.05)。两组之间存在明显差异。获得的双尾显著性值为 0.001(p < 0.05),与无涂层插入物相比具有统计学意义,表明设计矩阵的充分性,两组之间存在显著差异。在本实验研究的限制条件下,通过 CBN 涂层刀片车削的 Al-Si12Cu 合金比通过未涂层刀片车削的样品在提高 MRR 方面发挥了显著作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
NanoWorld Journal
NanoWorld Journal Materials Science-Polymers and Plastics
自引率
0.00%
发文量
8
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信