{"title":"Using a Disposable Flexible Fiberoptic Scope as a Bougie for Difficult Intubation","authors":"Daher K Rabadi, Sami A Almasarweh, A. Abubaker, Nedal Shawaqfeh, S. R. Alsalman, Zaid Madain","doi":"10.4103/jets.jets_63_23","DOIUrl":null,"url":null,"abstract":"In this case report, we describe two difficult intubations in which an endotracheal tube was threaded over a fiberoptic bronchoscope that was acting as a bougie. Our patients initially presented with limited neck extension, narrow mouth opening, and restricted view of the glottic region. A fiberoptic bronchoscope was guided through while the patient was oxygenated through a laryngeal mask. After the scope provided an unrestricted view of the vocal cords, the digital module was removed by cutting the fiberoptic thread, and an endotracheal tube was passed through. After proper confirmation of the endotracheal tube position, the intubation was deemed successful and thereby, we share our experience with the novel technique. This technique may potentially improve critical patient outcomes whether in trauma or an unexpectedly difficult intubation.","PeriodicalId":15692,"journal":{"name":"Journal of Emergencies, Trauma, and Shock","volume":"147 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2023-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Emergencies, Trauma, and Shock","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jets.jets_63_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

In this case report, we describe two difficult intubations in which an endotracheal tube was threaded over a fiberoptic bronchoscope that was acting as a bougie. Our patients initially presented with limited neck extension, narrow mouth opening, and restricted view of the glottic region. A fiberoptic bronchoscope was guided through while the patient was oxygenated through a laryngeal mask. After the scope provided an unrestricted view of the vocal cords, the digital module was removed by cutting the fiberoptic thread, and an endotracheal tube was passed through. After proper confirmation of the endotracheal tube position, the intubation was deemed successful and thereby, we share our experience with the novel technique. This technique may potentially improve critical patient outcomes whether in trauma or an unexpectedly difficult intubation.
使用一次性柔性光纤探头作为困难插管的导尿管
在本病例报告中,我们描述了两例困难插管,其中气管导管被穿在充当导气管的纤维支气管镜上。患者最初表现为颈部伸展受限、张口狭窄、声门区域视野受限。在通过喉罩为患者吸氧的同时,引导纤维支气管镜通过。在纤维支气管镜提供了不受限制的声带视野后,通过剪断光纤线取出数字模块,并通过气管导管。在正确确认气管导管位置后,插管被认为是成功的,因此我们分享了我们在这项新技术上的经验。无论是创伤还是意外的困难插管,这种技术都有可能改善危重病人的治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.90
自引率
7.10%
发文量
52
审稿时长
39 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信