{"title":"THE EXOGAM2 CALIBRATION USING THE NEWLY DEVELOPED NUMEXO2 DIGITAL ELECTRONIC","authors":"Elif Şahi̇n, Sefa Ertürk, Vakkas Bozkurt","doi":"10.55696/ejset.1312972","DOIUrl":null,"url":null,"abstract":"In this study, the calibration process of the EXOGAM2 conventional gamma detector system with the newly developed digital electronic device, namely NUMEXO2, will be presented. This experimental study was performed at the GANIL (Grand Accélérateur National d'Ions Lourds) nuclear research center in France. The energy calibration of the EXOGAM2 detector system with the newly developed NUMEXO2 digital electronic device was conducted using both low and high gamma energy levels of a 152Eu radioactive source. This calibration was carried out for two EXOGAM2 detectors, and the energy resolution of each crystal in the EXOGAM2 system was determined. The energy resolution of each crystal was found to be similar to the previously measured energy resolution values of the EXOGAM2 detectors. Therefore, the use of the digital electronic device NUMEXO2 did not affect the energy resolution of the detectors, but it did enable us to acquire data at a high counting rate.","PeriodicalId":143980,"journal":{"name":"Eurasian Journal of Science Engineering and Technology","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eurasian Journal of Science Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55696/ejset.1312972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, the calibration process of the EXOGAM2 conventional gamma detector system with the newly developed digital electronic device, namely NUMEXO2, will be presented. This experimental study was performed at the GANIL (Grand Accélérateur National d'Ions Lourds) nuclear research center in France. The energy calibration of the EXOGAM2 detector system with the newly developed NUMEXO2 digital electronic device was conducted using both low and high gamma energy levels of a 152Eu radioactive source. This calibration was carried out for two EXOGAM2 detectors, and the energy resolution of each crystal in the EXOGAM2 system was determined. The energy resolution of each crystal was found to be similar to the previously measured energy resolution values of the EXOGAM2 detectors. Therefore, the use of the digital electronic device NUMEXO2 did not affect the energy resolution of the detectors, but it did enable us to acquire data at a high counting rate.
使用新开发的 numexo2 数字电子设备对 exogam2 进行校准。
本研究将介绍 EXOGAM2 传统伽马探测器系统与新开发的数字电子装置 NUMEXO2 的校准过程。这项实验研究是在法国 GANIL(Grand Accélérateur National d'Ions Lourds)核研究中心进行的。使用新开发的 NUMEXO2 数字电子装置对 EXOGAM2 探测器系统进行了能量校准,校准使用了 152Eu 放射源的低伽马能级和高伽马能级。对两个 EXOGAM2 探测器进行了校准,并确定了 EXOGAM2 系统中每个晶体的能量分辨率。 结果发现,每个晶体的能量分辨率与之前测量的 EXOGAM2 探测器的能量分辨率值相似。因此,数字电子设备 NUMEXO2 的使用并没有影响探测器的能量分辨率,但却使我们能够以较高的计数率获取数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信