{"title":"INFLUENCE OF VASCULAR STENT SURFACE TREATMENT WITH AN ADAPTIVE COMPOSITION (AdC) FOR IMPROVING ITS BIOCOMPATIBILITY AND RESTENOSIS PREVENTION (experimental research)","authors":"H. Lazarenko, O. Lazarenko, V. Shaprynskyi, N. Semenenko","doi":"10.31612/2616-4868.5.2023.06","DOIUrl":null,"url":null,"abstract":"Introduction. The article describes a method of implant surface treatment that reduces the risk of an inflammatory reaction to vascular implants. The aim of the research was to develop a method of coating the surface of vascular implants (stents) to reduce the risk of inflammation reaction (rejection), enhance their biocompatibility, and prevent restenosis. Materials and methods. The research was conducted on 34 male rabbits of the \"Flemish Giant\" breed weighing 2.5-3.0 kg, following the standards of bioethical principles. The blood vessels of the experimental animals were previously provoked by the administration of endogenous pyrogenic solution according to a predetermined protocol. Under general anesthesia, the animals were endovascularly (via femoral access into the abdominal aorta) implanted with standard Z-shaped stents made of 316L stainless steel. To obtain indicative results, 10 rabbits were implanted with non-treated stents, while another 12 rabbits had stents pre-treated with the adapting composition (AdC) implanted. After 8 weeks, the animals were withdrawn from the experiment. Results and discussion. Vessel wall morphometry revealed that the treatment of stents with AdC before their placement into the vessel resulted in a reduction of vessel wall thickness at the site of their implantation. Conclusions. The developed method involves pre-treatment of stents with AdC , which in turn ensures a reduction in the reaction of the surrounding tissues thanks to the modification of the implant surface, reduces the thickness of neointima growth, which indicates the absence of inflammatory processes and the formation of fibrous tissue around the implant. The clinical application of AdC aimed at improving the biocompatibility properties of implants with respect to the recipient's body is characterized by a 100% (95% CI 78.2% - 100%) likelihood of absence of complications.","PeriodicalId":502404,"journal":{"name":"Clinical and Preventive Medicine","volume":"624 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Preventive Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31612/2616-4868.5.2023.06","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction. The article describes a method of implant surface treatment that reduces the risk of an inflammatory reaction to vascular implants. The aim of the research was to develop a method of coating the surface of vascular implants (stents) to reduce the risk of inflammation reaction (rejection), enhance their biocompatibility, and prevent restenosis. Materials and methods. The research was conducted on 34 male rabbits of the "Flemish Giant" breed weighing 2.5-3.0 kg, following the standards of bioethical principles. The blood vessels of the experimental animals were previously provoked by the administration of endogenous pyrogenic solution according to a predetermined protocol. Under general anesthesia, the animals were endovascularly (via femoral access into the abdominal aorta) implanted with standard Z-shaped stents made of 316L stainless steel. To obtain indicative results, 10 rabbits were implanted with non-treated stents, while another 12 rabbits had stents pre-treated with the adapting composition (AdC) implanted. After 8 weeks, the animals were withdrawn from the experiment. Results and discussion. Vessel wall morphometry revealed that the treatment of stents with AdC before their placement into the vessel resulted in a reduction of vessel wall thickness at the site of their implantation. Conclusions. The developed method involves pre-treatment of stents with AdC , which in turn ensures a reduction in the reaction of the surrounding tissues thanks to the modification of the implant surface, reduces the thickness of neointima growth, which indicates the absence of inflammatory processes and the formation of fibrous tissue around the implant. The clinical application of AdC aimed at improving the biocompatibility properties of implants with respect to the recipient's body is characterized by a 100% (95% CI 78.2% - 100%) likelihood of absence of complications.
用适应性复合材料(AdC)处理血管支架表面对提高其生物相容性和预防再狭窄的影响(实验研究)
导言。文章介绍了一种可降低血管植入物炎症反应风险的植入物表面处理方法。 研究的目的是开发一种血管植入物(支架)表面涂层的方法,以降低炎症反应(排斥反应)的风险,增强其生物相容性,防止再狭窄。 材料和方法。研究以 34 只体重为 2.5-3.0 公斤的 "弗拉芒巨人 "种雄性兔子为对象,遵循生物伦理原则标准。实验动物的血管事先按照预定方案通过内源性热原溶液进行了刺激。在全身麻醉的情况下,通过股动脉进入腹主动脉,为动物植入标准的 316L 不锈钢 Z 型支架。为了获得指示性结果,10 只兔子植入了未经处理的支架,另外 12 只兔子植入了预先用适应成分(AdC)处理过的支架。8 周后,动物退出实验。 结果与讨论血管壁形态测量显示,在将支架植入血管前用 AdC 进行处理可减少植入部位的血管壁厚度。 结论。所开发的方法包括用 AdC 对支架进行预处理,由于对植入物表面进行了改良,这反过来又能确保减少周围组织的反应,降低新生内膜生长的厚度,这表明植入物周围没有炎症过程和纤维组织的形成。AdC 的临床应用旨在改善植入物与受术者身体的生物相容性,其特点是没有并发症的可能性为 100%(95% CI 78.2% - 100%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信