Hieu Tran Trong, Huong Huynh Thi Thu, Son Le Van, Quang Nguyen Huu
{"title":"Study of the compartmental modelling method on the basic non-reactive tank","authors":"Hieu Tran Trong, Huong Huynh Thi Thu, Son Le Van, Quang Nguyen Huu","doi":"10.53747/nst.v12i2.342","DOIUrl":null,"url":null,"abstract":"The Compartment Model allows modeling the system flow to zones visually, in which each zone is characterized by a combination of basic mixing compartments. The localization of the flow zones, as well as the calculation of the volume zones and exchange rate between zones, was done based on the velocity field determined from the numerical simulation model. This study presents the results of applying the CM method to analyze the 2D basic non-reactive tank with dimensions of 100 cm x 100 cm x 10 cm and an inlet flow of about 3 - 6 L/min. The results show that the obtained CM model has 3 main flow zones including the convection zone, circulation zone and slow flow zone. The results of comparing the tracer response curves from the CM model and experiment with the root-mean-square error below 0,11 allow confirming the established CM model.","PeriodicalId":19445,"journal":{"name":"Nuclear Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53747/nst.v12i2.342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The Compartment Model allows modeling the system flow to zones visually, in which each zone is characterized by a combination of basic mixing compartments. The localization of the flow zones, as well as the calculation of the volume zones and exchange rate between zones, was done based on the velocity field determined from the numerical simulation model. This study presents the results of applying the CM method to analyze the 2D basic non-reactive tank with dimensions of 100 cm x 100 cm x 10 cm and an inlet flow of about 3 - 6 L/min. The results show that the obtained CM model has 3 main flow zones including the convection zone, circulation zone and slow flow zone. The results of comparing the tracer response curves from the CM model and experiment with the root-mean-square error below 0,11 allow confirming the established CM model.
分区模型可以直观地模拟系统的分区流动,其中每个分区都由基本混合分区组合而成。流动区域的定位以及体积区域和区域间交换率的计算都是根据数值模拟模型确定的速度场进行的。本研究介绍了应用 CM 方法分析二维基本非反应槽的结果,该槽的尺寸为 100 厘米 x 100 厘米 x 10 厘米,入口流量约为 3 - 6 升/分钟。结果表明,得到的 CM 模型有 3 个主要流动区,包括对流区、循环区和缓流区。 通过比较 CM 模型和实验的示踪响应曲线,均方根误差低于 0.11,从而证实了所建立的 CM 模型。