EFFECT OF ACUTE FOAM ROLLER AND PERCUSSION THERAPY ON MUSCLE ARCHITECTURE AND MUSCLE STIFFNESS

Maryam Yektaei̇, O. Akkoç, S. Devran, Imren Kurtdere, Özlem Kirandi, B. Bayraktar
{"title":"EFFECT OF ACUTE FOAM ROLLER AND PERCUSSION THERAPY ON MUSCLE ARCHITECTURE AND MUSCLE STIFFNESS","authors":"Maryam Yektaei̇, O. Akkoç, S. Devran, Imren Kurtdere, Özlem Kirandi, B. Bayraktar","doi":"10.33689/spormetre.1270945","DOIUrl":null,"url":null,"abstract":"The aim of the study is to investigate the effect of the acute application of foam roller and massage gun, which are self-myofascial techniques, on muscle architecture and muscle stiffness. 27 male athletes participated in the study. Within the scope of the study, the athletes were randomly divided into 3 groups as 1st group foam roller (FR), 2nd group massage gun (MG), 3rd group as control group (CG) and muscle architecture and muscle stiffness (MS) were evaluated as a result of acute exercise. Muscle stiffness (MS) muscle thickness (MT), cross-sectional area (CSA), and pennate angles (PA) of the subjects were measured by ultrasound. The measurement results were tested with repeated measures two-way Anova test analysis of variance in the SPSS program, and significance was accepted as p<0.05. When the measurement results of MS, PA, and MT were examined, no significant difference was observed in the FR, MG, and CG pre-test and post-test (p= 0.94). In the pretest and posttest results of the CSA of the muscle, a decrease was observed in the FR group and an increase in the MG group (p=0.03). In conclusion; shows that muscle thickness,pennation angle, and muscle stiffness do not change after acute self-myofascial relaxations and that foam roller and massage gun do not have superiority over each other. The cross-sectional area decreased after the foam roller application and increased after the massage gun.","PeriodicalId":372031,"journal":{"name":"Ankara Üniversitesi Beden Eğitimi ve Spor Yüksekokulu SPORMETRE Beden Eğitimi ve Spor Bilimleri Dergisi","volume":"201 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ankara Üniversitesi Beden Eğitimi ve Spor Yüksekokulu SPORMETRE Beden Eğitimi ve Spor Bilimleri Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33689/spormetre.1270945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the study is to investigate the effect of the acute application of foam roller and massage gun, which are self-myofascial techniques, on muscle architecture and muscle stiffness. 27 male athletes participated in the study. Within the scope of the study, the athletes were randomly divided into 3 groups as 1st group foam roller (FR), 2nd group massage gun (MG), 3rd group as control group (CG) and muscle architecture and muscle stiffness (MS) were evaluated as a result of acute exercise. Muscle stiffness (MS) muscle thickness (MT), cross-sectional area (CSA), and pennate angles (PA) of the subjects were measured by ultrasound. The measurement results were tested with repeated measures two-way Anova test analysis of variance in the SPSS program, and significance was accepted as p<0.05. When the measurement results of MS, PA, and MT were examined, no significant difference was observed in the FR, MG, and CG pre-test and post-test (p= 0.94). In the pretest and posttest results of the CSA of the muscle, a decrease was observed in the FR group and an increase in the MG group (p=0.03). In conclusion; shows that muscle thickness,pennation angle, and muscle stiffness do not change after acute self-myofascial relaxations and that foam roller and massage gun do not have superiority over each other. The cross-sectional area decreased after the foam roller application and increased after the massage gun.
急性泡沫滚筒和敲击疗法对肌肉结构和肌肉僵硬的影响
这项研究的目的是调查急性应用泡沫滚筒和按摩枪这种自我肌筋膜技术对肌肉结构和肌肉僵硬的影响。27 名男性运动员参与了这项研究。在研究范围内,运动员被随机分为三组,第一组为泡沫滚筒组(FR),第二组为按摩枪组(MG),第三组为对照组(CG),并对急性运动后的肌肉结构和肌肉僵硬度(MS)进行评估。通过超声波测量受试者的肌肉僵硬度(MS)、肌肉厚度(MT)、横截面积(CSA)和五点角(PA)。测量结果采用 SPSS 程序中的重复测量双向 Anova 检验进行方差分析,以 P<0.05 为显著性。在对 MS、PA 和 MT 的测量结果进行检验时,发现 FR、MG 和 CG 在测试前和测试后没有明显差异(P= 0.94)。在肌肉 CSA 的测试前和测试后结果中,观察到 FR 组有所下降,而 MG 组有所上升(P=0.03)。总之,急性自我肌筋膜放松后,肌肉厚度、绷角和肌肉僵硬度没有变化,泡沫滚筒和按摩枪也没有优劣之分。使用泡沫滚筒后横截面积减少,而使用按摩枪后横截面积增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信