{"title":"AUTOMATIC ADJUSTMENT OF REACTIVE POWER BY FACTS DEVICES UNDER CONDITIONS OF VOLTAGE INSTABILITY IN THE ELECTRIC NETWORK","authors":"Mykhailo Burbelo, Oleksii Babenko, Yurii Loboda, Denys Lebed, Oleg K. Kolesnytskyj, Saule J. Rakhmetullina, Murat Mussabekov","doi":"10.35784/iapgos.5377","DOIUrl":null,"url":null,"abstract":"This article describes the problem of automatic regulation of reactive power using electronic devices FACTS (Flexible AC Transmission Systems): static synchronous compensator (STATCOM) and unified power flow controller (UPFC). With the help of a complex writing form, the following are determined: voltages at the installation nodes of the FACTS device and loads, currents of loads, power sources and electronic compensators in case of voltage instability at the load node of the electrical network. Voltages and currents are determined using the node-voltage method. The task of STATCOM is partial or full compensation of reactive power. During the reduction of the voltage at the load node, the reactive power generated by the power source decreases. The STATCOM should partially or fully compensate for the reactive power imbalance as quickly as possible. However, at the same time, it is not possible to fully compensate for the voltage reduction. A series-parallel or parallel-series UPFC can be used to solve this problem. As a result of using the UPFC, it is possible to automatically raise the voltage level to acceptable values with the help of the UPFC series compensator. The analysis shows that the parallel-serial UPFC is characterized by the stability of operation. In the case of using a series-parallel UPFC, there are restrictions on the ability to adjust the imaginary voltage component of the series compensator, since the angle of the voltage vector changes, which causes a failure in the operation of the regulator of the parallel compensator UPFC.","PeriodicalId":504633,"journal":{"name":"Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska","volume":"455 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35784/iapgos.5377","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This article describes the problem of automatic regulation of reactive power using electronic devices FACTS (Flexible AC Transmission Systems): static synchronous compensator (STATCOM) and unified power flow controller (UPFC). With the help of a complex writing form, the following are determined: voltages at the installation nodes of the FACTS device and loads, currents of loads, power sources and electronic compensators in case of voltage instability at the load node of the electrical network. Voltages and currents are determined using the node-voltage method. The task of STATCOM is partial or full compensation of reactive power. During the reduction of the voltage at the load node, the reactive power generated by the power source decreases. The STATCOM should partially or fully compensate for the reactive power imbalance as quickly as possible. However, at the same time, it is not possible to fully compensate for the voltage reduction. A series-parallel or parallel-series UPFC can be used to solve this problem. As a result of using the UPFC, it is possible to automatically raise the voltage level to acceptable values with the help of the UPFC series compensator. The analysis shows that the parallel-serial UPFC is characterized by the stability of operation. In the case of using a series-parallel UPFC, there are restrictions on the ability to adjust the imaginary voltage component of the series compensator, since the angle of the voltage vector changes, which causes a failure in the operation of the regulator of the parallel compensator UPFC.
在电网电压不稳定的情况下,通过事实设备自动调节无功功率
本文介绍了利用电子设备 FACTS(柔性交流输电系统)自动调节无功功率的问题:静态同步补偿器 (STATCOM) 和统一功率流控制器 (UPFC)。借助复杂的书写形式,可确定以下内容:FACTS 设备安装节点和负载的电压,电网负载节点电压不稳定时负载、电源和电子补偿器的电流。电压和电流采用节点电压法确定。STATCOM 的任务是部分或全部补偿无功功率。在负载节点电压降低期间,电源产生的无功功率也会降低。STATCOM 应尽快部分或全部补偿无功功率失衡。但与此同时,也不可能完全补偿电压的降低。串并联或并串联 UPFC 可用于解决这一问题。使用 UPFC 后,在 UPFC 串联补偿器的帮助下,可以自动将电压水平提高到可接受的值。分析表明,并串联 UPFC 的特点是运行稳定。而在使用串并联 UPFC 的情况下,由于电压矢量的角度会发生变化,因此调节串联补偿器虚电压分量的能力会受到限制,从而导致并联补偿器 UPFC 的调节器无法正常工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信