Remote administration of the short physical performance battery, the 1-minute sit to stand, and the Chester step test in post-COVID-19 patients after hospitalization: establishing inter-reliability and agreement with the face-to-face assessment.

IF 2.1 4区 医学 Q1 REHABILITATION
Disability and Rehabilitation Pub Date : 2024-11-01 Epub Date: 2023-12-29 DOI:10.1080/09638288.2023.2297928
Aspasia Mavronasou, Andreas Asimakos, Aristeidis Vasilopoulos, Paraskevi Katsaounou, Eleni A Kortianou
{"title":"Remote administration of the short physical performance battery, the 1-minute sit to stand, and the Chester step test in post-COVID-19 patients after hospitalization: establishing inter-reliability and agreement with the face-to-face assessment.","authors":"Aspasia Mavronasou, Andreas Asimakos, Aristeidis Vasilopoulos, Paraskevi Katsaounou, Eleni A Kortianou","doi":"10.1080/09638288.2023.2297928","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the inter-reliability of the Short Physical Performance Battery (SPPB), the 1-min Sit to Stand test (1-MSTS), and the Chester Step Test (CST) via remote assessment in post-COVID-19 patients after hospitalization.</p><p><strong>Methods: </strong>Twenty-five post-COVID-19 patients randomly performed the functional tests via remote assessment using a software platform at home and via face-to-face assessment at the rehabilitation center 24-72 h apart. One day before the remote assessment, all participants had a 1-h guidance session regarding the platform use, safety instructions, and home equipment preparation.</p><p><strong>Results: </strong>Participants completed all tests for both assessment procedures without experience of adverse events. The mean age was 53 (SD = 10) years old, and the median days of hospitalization were 23 (IQR = 10-33). The inter-reliability was moderate for the total score in the SPPB: Cohen's kappa = 0.545 (95% CI: 0.234 to 0.838), excellent for the number of repetitions in the 1-MSTS: ICC = 0.977 (95% CI: 0.948 to 0.990) and good for the total number of steps in the CST: ICC = 0.871 (95% CI: 0.698 to 0.944).</p><p><strong>Conclusion: </strong>Remote functional assessments for SPPB, 1-MSTS, and CST indicated moderate to excellent inter-reliability in post-COVID-19 patients after hospitalization.</p>","PeriodicalId":50575,"journal":{"name":"Disability and Rehabilitation","volume":" ","pages":"5334-5344"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Disability and Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09638288.2023.2297928","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the inter-reliability of the Short Physical Performance Battery (SPPB), the 1-min Sit to Stand test (1-MSTS), and the Chester Step Test (CST) via remote assessment in post-COVID-19 patients after hospitalization.

Methods: Twenty-five post-COVID-19 patients randomly performed the functional tests via remote assessment using a software platform at home and via face-to-face assessment at the rehabilitation center 24-72 h apart. One day before the remote assessment, all participants had a 1-h guidance session regarding the platform use, safety instructions, and home equipment preparation.

Results: Participants completed all tests for both assessment procedures without experience of adverse events. The mean age was 53 (SD = 10) years old, and the median days of hospitalization were 23 (IQR = 10-33). The inter-reliability was moderate for the total score in the SPPB: Cohen's kappa = 0.545 (95% CI: 0.234 to 0.838), excellent for the number of repetitions in the 1-MSTS: ICC = 0.977 (95% CI: 0.948 to 0.990) and good for the total number of steps in the CST: ICC = 0.871 (95% CI: 0.698 to 0.944).

Conclusion: Remote functional assessments for SPPB, 1-MSTS, and CST indicated moderate to excellent inter-reliability in post-COVID-19 patients after hospitalization.

远程管理 COVID-19 后患者住院后的短期体能测试、1 分钟坐立测试和切斯特台阶测试:建立与面对面评估的相互可靠性和一致性。
目的:通过远程评估,评估COVID-19患者住院后短期体能测试(SPPB)、1分钟坐立测试(1-MSTS)和切斯特台阶测试(CST)的相互可靠性:25名COVID-19术后患者随机在家中通过软件平台进行远程评估,并在康复中心通过面对面评估进行功能测试,两者相隔24-72小时。在进行远程评估的前一天,所有参与者都接受了为期 1 小时的指导,内容包括平台使用、安全说明和家庭设备准备:结果:参与者完成了两个评估程序的所有测试,未出现不良反应。平均年龄为 53(SD = 10)岁,住院天数中位数为 23(IQR = 10-33)天。SPPB 总分的相互可信度为中等:Cohen's kappa = 0.545(95% CI:0.234 至 0.838),1-MSTS 重复次数的相互可信度为优:ICC=0.977(95% CI:0.948-0.990),CST总步数的ICC=0.871(95% CI:0.698-0.944):结论:SPPB、1-MSTS 和 CST 的远程功能评估显示,COVID-19 后患者住院后的相互可靠性达到了中等至优秀水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Disability and Rehabilitation
Disability and Rehabilitation 医学-康复医学
CiteScore
5.00
自引率
9.10%
发文量
415
审稿时长
3-6 weeks
期刊介绍: Disability and Rehabilitation along with Disability and Rehabilitation: Assistive Technology are international multidisciplinary journals which seek to encourage a better understanding of all aspects of disability and to promote rehabilitation science, practice and policy aspects of the rehabilitation process.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信