The Association of Physiological and Pharmacological Anesthetic Parameters With Motor-Evoked Potentials: A Multivariable Longitudinal Mixed Model Analysis.

IF 4.6 2区 医学 Q1 ANESTHESIOLOGY
Anesthesia and analgesia Pub Date : 2024-09-01 Epub Date: 2023-12-28 DOI:10.1213/ANE.0000000000006757
Sebastiaan Eckhardt Dulfer, Henk Groen, Robertus J M Groen, Anthony R Absalom, Marko M Sahinovic, Gea Drost
{"title":"The Association of Physiological and Pharmacological Anesthetic Parameters With Motor-Evoked Potentials: A Multivariable Longitudinal Mixed Model Analysis.","authors":"Sebastiaan Eckhardt Dulfer, Henk Groen, Robertus J M Groen, Anthony R Absalom, Marko M Sahinovic, Gea Drost","doi":"10.1213/ANE.0000000000006757","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>During spinal surgery, the motor tracts can be monitored using muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs). We aimed to investigate the association of anesthetic and physiological parameters with mTc-MEPs.</p><p><strong>Methods: </strong>Intraoperative mTc-MEP amplitudes, mTc-MEP area under the curves (AUC), and anesthetic and physiological measurements were collected retrospectively from the records of 108 consecutive patients undergoing elective spinal surgery. Pharmacological parameters of interest included propofol and opioid concentration, ketamine and noradrenaline infusion rates. Physiological parameters recorded included mean arterial pressure (MAP), bispectral index (BIS), heart rate, hemoglobin O 2 saturation, temperature, and Et co2 . A forward selection procedure was performed using multivariable mixed model analysis.</p><p><strong>Results: </strong>Data from 75 (69.4%) patients were included. MAP and BIS were significantly associated with mTc-MEP amplitude ( P < .001). mTc-MEP amplitudes increased by 6.6% (95% confidence interval [CI], 2.7%-10.4%) per 10 mm Hg increase in MAP and by 2.79% (CI, 2.26%-3.32%) for every unit increase in BIS. MAP ( P < .001), BIS ( P < .001), heart rate ( P = .01), and temperature ( P = .02) were significantly associated with mTc-MEP AUC. The AUC increased by 7.5% (CI, 3.3%-11.7%) per 10 mm Hg increase of MAP, by 2.98% (CI, 2.41%-3.54%) per unit increase in BIS, and by 0.68% (CI, 0.13%-1.23%) per beat per minute increase in heart rate. mTc-MEP AUC decreased by 21.4% (CI, -38.11% to -3.98%) per degree increase in temperature.</p><p><strong>Conclusions: </strong>MAP, BIS, heart rate, and temperature were significantly associated with mTc-MEP amplitude and/or AUC. Maintenance of BIS and MAP at the high normal values may attenuate anesthetic effects on mTc-MEPs.</p>","PeriodicalId":7784,"journal":{"name":"Anesthesia and analgesia","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11305622/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anesthesia and analgesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1213/ANE.0000000000006757","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: During spinal surgery, the motor tracts can be monitored using muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs). We aimed to investigate the association of anesthetic and physiological parameters with mTc-MEPs.

Methods: Intraoperative mTc-MEP amplitudes, mTc-MEP area under the curves (AUC), and anesthetic and physiological measurements were collected retrospectively from the records of 108 consecutive patients undergoing elective spinal surgery. Pharmacological parameters of interest included propofol and opioid concentration, ketamine and noradrenaline infusion rates. Physiological parameters recorded included mean arterial pressure (MAP), bispectral index (BIS), heart rate, hemoglobin O 2 saturation, temperature, and Et co2 . A forward selection procedure was performed using multivariable mixed model analysis.

Results: Data from 75 (69.4%) patients were included. MAP and BIS were significantly associated with mTc-MEP amplitude ( P < .001). mTc-MEP amplitudes increased by 6.6% (95% confidence interval [CI], 2.7%-10.4%) per 10 mm Hg increase in MAP and by 2.79% (CI, 2.26%-3.32%) for every unit increase in BIS. MAP ( P < .001), BIS ( P < .001), heart rate ( P = .01), and temperature ( P = .02) were significantly associated with mTc-MEP AUC. The AUC increased by 7.5% (CI, 3.3%-11.7%) per 10 mm Hg increase of MAP, by 2.98% (CI, 2.41%-3.54%) per unit increase in BIS, and by 0.68% (CI, 0.13%-1.23%) per beat per minute increase in heart rate. mTc-MEP AUC decreased by 21.4% (CI, -38.11% to -3.98%) per degree increase in temperature.

Conclusions: MAP, BIS, heart rate, and temperature were significantly associated with mTc-MEP amplitude and/or AUC. Maintenance of BIS and MAP at the high normal values may attenuate anesthetic effects on mTc-MEPs.

生理和药理麻醉参数与运动诱发电位的关系:多变量纵向混合模型分析
背景:在脊柱手术过程中,可以使用肌肉记录的经颅电刺激运动诱发电位(mTc-MEPs)来监测运动束。我们旨在研究麻醉和生理参数与 mTc-MEPs 的关联:我们从 108 名连续接受择期脊柱手术的患者的记录中回顾性地收集了术中 mTc-MEP 波幅、mTc-MEP 曲线下面积(AUC)以及麻醉和生理参数。相关药理参数包括异丙酚和阿片类药物浓度、氯胺酮和去甲肾上腺素输注率。记录的生理参数包括平均动脉压 (MAP)、双谱指数 (BIS)、心率、血红蛋白 O2 饱和度、体温和 Etco2。使用多变量混合模型分析进行了前向选择程序:结果:共纳入 75 名(69.4%)患者的数据。MAP 和 BIS 与 mTc-MEP 振幅明显相关(P < .001)。MAP 每增加 10 mm Hg,mTc-MEP 振幅增加 6.6%(95% 置信区间 [CI],2.7%-10.4%);BIS 每增加一个单位,mTc-MEP 振幅增加 2.79%(CI,2.26%-3.32%)。MAP (P < .001)、BIS (P < .001)、心率 (P = .01) 和体温 (P = .02) 与 mTc-MEP AUC 显著相关。MAP 每增加 10 mm Hg,AUC 增加 7.5% (CI,3.3%-11.7%);BIS 每增加一个单位,AUC 增加 2.98% (CI,2.41%-3.54%);心率每增加一分钟,AUC 增加 0.68% (CI,0.13%-1.23%):结论:MAP、BIS、心率和体温与 mTc-MEP 振幅和/或 AUC 显著相关。将 BIS 和 MAP 维持在正常高值可减轻麻醉剂对 mTc-MEPs 的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Anesthesia and analgesia
Anesthesia and analgesia 医学-麻醉学
CiteScore
9.90
自引率
7.00%
发文量
817
审稿时长
2 months
期刊介绍: Anesthesia & Analgesia exists for the benefit of patients under the care of health care professionals engaged in the disciplines broadly related to anesthesiology, perioperative medicine, critical care medicine, and pain medicine. The Journal furthers the care of these patients by reporting the fundamental advances in the science of these clinical disciplines and by documenting the clinical, laboratory, and administrative advances that guide therapy. Anesthesia & Analgesia seeks a balance between definitive clinical and management investigations and outstanding basic scientific reports. The Journal welcomes original manuscripts containing rigorous design and analysis, even if unusual in their approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信