Validación de test de flexión-relajación para definir un déficit lumbar con electrodos tetrapolares

Q3 Medicine
Y. Domínguez Ponce, J. García Díaz, J. Vargas Montes, M.E. Romero Díez
{"title":"Validación de test de flexión-relajación para definir un déficit lumbar con electrodos tetrapolares","authors":"Y. Domínguez Ponce,&nbsp;J. García Díaz,&nbsp;J. Vargas Montes,&nbsp;M.E. Romero Díez","doi":"10.1016/j.rh.2023.100823","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction and objective</h3><p>To obtain a new cut-off point (CP) for a lumbar flexion-relaxation (RF) test established with tetrapolar (e.) electrodes, from values already defined with bipolar devices.</p></div><div><h3>Materials and methods</h3><p>The study sample consists of 47 patients in a situation of temporary disability due to low back pain (DL). They were evaluated by means of an isometric dynamometry test, a kinematic test and an assessment of the FR phenomenon.</p><p>Two experiments with ROC curves are proposed. The first, with 47 patients who consecutively performed the RF test with both types of electrodes, using the cut-off point (CP) known for the e. bipolar (2.49<!--> <!-->μV). In the second, with the EMG data recorded with e. tetrapolar in 17 patients, a DeLong test was performed that compares the 2 ROC curves that were constructed on the one hand, by classifying the sample from dynamometry and kinematic tests, and on the other, by classifying them with the bipolar EMG values.</p></div><div><h3>Results</h3><p>A total of 34 patients adequately completed the evaluations of the first experiment and 17 patients the second. The first study shows a cut-off point of 1.2<!--> <!-->μV, with an AUC of 87.7%; Sensitivity 84.2% and Specificity 80%. The second shows a PC for e. bipolars of 1.21<!--> <!-->μV (AUC 87.5%) and for e. tetrapolar values of 1.43 (AUC 82.5%) with a DeLong test without significant differences between both curves (<em>p</em> <!-->&gt;<!--> <!-->0.4065).</p></div><div><h3>Conclusions</h3><p>The validation methodology with ROC curves has made it possible to obtain a new PC for the RF test in a practical way, simply by simultaneously performing both tests on the same group of patients until a significant sample is obtained.</p></div>","PeriodicalId":39532,"journal":{"name":"Rehabilitacion","volume":"58 2","pages":"Article 100823"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rehabilitacion","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0048712023000439","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and objective

To obtain a new cut-off point (CP) for a lumbar flexion-relaxation (RF) test established with tetrapolar (e.) electrodes, from values already defined with bipolar devices.

Materials and methods

The study sample consists of 47 patients in a situation of temporary disability due to low back pain (DL). They were evaluated by means of an isometric dynamometry test, a kinematic test and an assessment of the FR phenomenon.

Two experiments with ROC curves are proposed. The first, with 47 patients who consecutively performed the RF test with both types of electrodes, using the cut-off point (CP) known for the e. bipolar (2.49 μV). In the second, with the EMG data recorded with e. tetrapolar in 17 patients, a DeLong test was performed that compares the 2 ROC curves that were constructed on the one hand, by classifying the sample from dynamometry and kinematic tests, and on the other, by classifying them with the bipolar EMG values.

Results

A total of 34 patients adequately completed the evaluations of the first experiment and 17 patients the second. The first study shows a cut-off point of 1.2 μV, with an AUC of 87.7%; Sensitivity 84.2% and Specificity 80%. The second shows a PC for e. bipolars of 1.21 μV (AUC 87.5%) and for e. tetrapolar values of 1.43 (AUC 82.5%) with a DeLong test without significant differences between both curves (p > 0.4065).

Conclusions

The validation methodology with ROC curves has made it possible to obtain a new PC for the RF test in a practical way, simply by simultaneously performing both tests on the same group of patients until a significant sample is obtained.

[利用四极电极验证屈曲-放松测试以确定腰椎损伤]。
简介和目的:从双极装置已确定的数值中,为使用四极(e.)电极进行的腰椎屈曲放松(RF)测试确定一个新的临界点(CP):研究样本包括 47 名因腰痛(DL)而暂时致残的患者。他们通过等长测力测试、运动测试和 FR 现象评估进行评估。我们提出了两个带有 ROC 曲线的实验。第一项实验使用已知的双极(2.49μV)分界点(CP),对 47 名患者使用两种类型的电极连续进行射频测试。其次,利用 17 名患者的四极肌电图数据,进行了 DeLong 测试,比较了两条 ROC 曲线,一条是通过测力和运动测试对样本进行分类,另一条是通过双极肌电图值对样本进行分类:共有 34 名患者完成了第一次实验的评估,17 名患者完成了第二次实验的评估。第一项研究显示,截断点为 1.2μV,AUC 为 87.7%;灵敏度为 84.2%,特异度为 80%。第二项研究显示,通过 DeLong 检验,双极电子的 PC 值为 1.21μV(AUC 87.5%),四极电子的 PC 值为 1.43(AUC 82.5%),两条曲线之间无显著差异(P>0.4065):使用 ROC 曲线的验证方法,只需对同一组患者同时进行两种测试,直到获得重要样本,就能以实用的方式为射频测试获得新的 PC 值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Rehabilitacion
Rehabilitacion Medicine-Rehabilitation
CiteScore
0.80
自引率
0.00%
发文量
63
期刊介绍: La revista que es desde hace más de 40 años la publicación oficial de la Sociedad Española de Rehabilitación y referente de la mayoría de las Sociedades de la Especialidad de los países americanos de habla hispana. Se publican 5 números pluritemáticos al año y uno monográfico sobre un tema del mayor interés y actualidad designado por el consejo de redacción.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信