{"title":"Striving to be the fittest: quantitative P2/N95 respirator fit test results among hospital staff during the COVID-19 pandemic","authors":"Melanie (Meilun) Zhang, L. Hackett, Jesse Smith, Zoe Pritchard, Matthew Casey, C. Low, P. Buntine","doi":"10.1017/ash.2023.503","DOIUrl":null,"url":null,"abstract":"Abstract Objective: To provide fit rates for specific P2/N95 respirators and compare these results by age, sex, clean-shaven status, and fit tester experience. Design: Exploratory audit involving secondary analysis of existing quantitative fit testing data. Setting: In response to the COVID-19 pandemic, healthcare services across Australia implemented respiratory protection protocols. This study details healthcare workers’ (HCWs) fit testing results from a large Victorian public health service. Participants: Fit-tested employees of a large tertiary public health network. Methods: Fit rates for ten individual P2/N95 respirators were calculated, and the effect of age, sex, clean-shaven status, and fit tester experience was examined via logistic regression. Results: 4593 employees were included, with 97.98% successfully fitting at least one respirator. Males were found to have significantly increased odds of achieving fit success compared to females (OR 11.61 95%CI 1.60–84.10). Fit rates dropped by 4% with each 1-year age increase (OR 0.96 95%CI 0.94–0.98). Clean-shaven individuals were also more likely to achieve a fit compared to non-clean-shaved individuals (OR 79.23 95%CI 10.21–614.62). More experienced fit testers also yielded significantly higher fit rates (OR 3.95, 95%CI 2.34–6.67). Conclusions: 98% of staff achieved a successful fitting of at least one respirator, with three-panel flat fold models (Industree Trident, 3M Aura 9320A+, and 3M Aura 1870+) performing the most consistently. An individual’s ability to achieve a successful fit was associated with; male sex, younger age, clean-shaven status, and fit tester experience.","PeriodicalId":7953,"journal":{"name":"Antimicrobial Stewardship & Healthcare Epidemiology","volume":"22 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Antimicrobial Stewardship & Healthcare Epidemiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/ash.2023.503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Objective: To provide fit rates for specific P2/N95 respirators and compare these results by age, sex, clean-shaven status, and fit tester experience. Design: Exploratory audit involving secondary analysis of existing quantitative fit testing data. Setting: In response to the COVID-19 pandemic, healthcare services across Australia implemented respiratory protection protocols. This study details healthcare workers’ (HCWs) fit testing results from a large Victorian public health service. Participants: Fit-tested employees of a large tertiary public health network. Methods: Fit rates for ten individual P2/N95 respirators were calculated, and the effect of age, sex, clean-shaven status, and fit tester experience was examined via logistic regression. Results: 4593 employees were included, with 97.98% successfully fitting at least one respirator. Males were found to have significantly increased odds of achieving fit success compared to females (OR 11.61 95%CI 1.60–84.10). Fit rates dropped by 4% with each 1-year age increase (OR 0.96 95%CI 0.94–0.98). Clean-shaven individuals were also more likely to achieve a fit compared to non-clean-shaved individuals (OR 79.23 95%CI 10.21–614.62). More experienced fit testers also yielded significantly higher fit rates (OR 3.95, 95%CI 2.34–6.67). Conclusions: 98% of staff achieved a successful fitting of at least one respirator, with three-panel flat fold models (Industree Trident, 3M Aura 9320A+, and 3M Aura 1870+) performing the most consistently. An individual’s ability to achieve a successful fit was associated with; male sex, younger age, clean-shaven status, and fit tester experience.
努力成为最合适的人:COVID-19 大流行期间医院工作人员的 P2/N95 呼吸器密合度定量测试结果
摘要 目的:提供特定 P2/N95 呼吸器的密合率,并根据年龄、性别、剃须情况和密合度测试人员的经验对这些结果进行比较。设计:探索性审核,包括对现有密合度测试量化数据的二次分析。设置:为应对 COVID-19 大流行,澳大利亚各地的医疗保健服务机构实施了呼吸防护协议。本研究详细介绍了维多利亚州一家大型公共卫生服务机构的医护人员(HCWs)密合度测试结果。参与人员一家大型三级公共卫生网络中接受密合度测试的员工。测试方法计算了十种 P2/N95 呼吸器的密合率,并通过逻辑回归分析了年龄、性别、剃须状况和密合度测试人员经验的影响。结果:共纳入 4593 名员工,其中 97.98% 的员工成功佩戴了至少一款呼吸器。与女性相比,男性成功佩戴的几率明显增加(OR 11.61 95%CI 1.60-84.10)。年龄每增加 1 岁,配戴成功率下降 4%(OR 0.96 95%CI 0.94-0.98)。与不刮胡子的人相比,胡子刮得干净的人也更有可能达到适合度(OR 79.23 95%CI 10.21-614.62)。经验更丰富的密合度测试人员的密合度也明显更高(OR 3.95,95%CI 2.34-6.67)。结论98%的工作人员至少成功配戴了一种呼吸器,其中三面板平折型呼吸器(Industree Trident、3M Aura 9320A+ 和 3M Aura 1870+)的配戴效果最为稳定。个人成功佩戴的能力与以下因素有关:男性、年轻、剃须干净以及佩戴测试人员的经验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信