[Investigation on reduction of radiation dose and optimization of exposure parameters in radiography].

Q4 Medicine
D S Fei
{"title":"[Investigation on reduction of radiation dose and optimization of exposure parameters in radiography].","authors":"D S Fei","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Investigation and measurement of the radiation dose level of routine X-ray diagnostic examinations were carried out on the spot, the results were as follows: Radiation dose of routine radiography: chest 0.258-1.032 x 10(-4) c/kg (0.1-0.4R); spinal and abdomen 0.774-1.806 x 10(-4) c/kg (0.3-0.7R); skull 0.774-1.032 x 10(-4) c/kg (0.3-0.4R) and gastrointestinal study 2.58-7.74 x 10(-4) c/kg (1-3R). Experiments employing different kV and mAs, and radiation exposure on 12-18 mm A1 phantoms while measuring the radiation dose and film density showed that radiation dose can be substantially reduced by improving the quality of X-ray beam for instance with the routine radiographic parameters for the chest, if the voltage is increased by 20 kV, radiation dose can be reduced to 65% or an additional 2 mm A1 filter can also reduce the dose to 60-65%.</p>","PeriodicalId":39377,"journal":{"name":"Zhonghua fang she xue za zhi Chinese journal of radiology","volume":"23 2","pages":"104-7"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua fang she xue za zhi Chinese journal of radiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Investigation and measurement of the radiation dose level of routine X-ray diagnostic examinations were carried out on the spot, the results were as follows: Radiation dose of routine radiography: chest 0.258-1.032 x 10(-4) c/kg (0.1-0.4R); spinal and abdomen 0.774-1.806 x 10(-4) c/kg (0.3-0.7R); skull 0.774-1.032 x 10(-4) c/kg (0.3-0.4R) and gastrointestinal study 2.58-7.74 x 10(-4) c/kg (1-3R). Experiments employing different kV and mAs, and radiation exposure on 12-18 mm A1 phantoms while measuring the radiation dose and film density showed that radiation dose can be substantially reduced by improving the quality of X-ray beam for instance with the routine radiographic parameters for the chest, if the voltage is increased by 20 kV, radiation dose can be reduced to 65% or an additional 2 mm A1 filter can also reduce the dose to 60-65%.

放射照相中降低辐射剂量及优化照射参数的探讨
现场对常规x线诊断检查放射剂量水平进行调查测量,结果如下:常规x线放射剂量:胸部0.258 ~ 1.032 × 10(-4) c/kg (0.1 ~ 0.4 r);脊柱和腹部0.774-1.806 x 10(-4) c/kg (0.3-0.7R);颅骨0.774-1.032 × 10(-4) c/kg (0.3-0.4R),胃肠道研究2.58-7.74 × 10(-4) c/kg (1-3R)。实验采用不同的kV和mAs,并在12-18 mm A1模型上进行辐射照射,同时测量辐射剂量和膜密度,结果表明,通过提高x射线束的质量可以大大降低辐射剂量,例如胸部常规放射参数,如果电压增加20 kV,辐射剂量可以降低到65%,或者增加2 mm A1滤光片也可以将剂量降低到60-65%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Zhonghua fang she xue za zhi Chinese journal of radiology
Zhonghua fang she xue za zhi Chinese journal of radiology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.30
自引率
0.00%
发文量
10639
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信