{"title":"Fragments of hydrophilic polymer coating as an embolic material – rare complication and potential cause of death","authors":"Slezak, Bloch-Bogusławska, Grzanka","doi":"10.4467/16891716amsik.23.014.18689","DOIUrl":null,"url":null,"abstract":"The most common complications of percutaneous coronary interventions and other endovascular procedures include minor hemorrhage, hematoma, or infection at the insertion site [1]. Much more serious ones include damage to the vessel wall, dissection, shock from contrast administration, acute kidney injury, myocardial infarction [2] and ischemic stroke [3]. Ischemic complications can be caused by an embolic incident due to a thrombus formation or detachment of atherosclerotic plaque fragments [3]. A rarely diagnosed complication is ischemia caused by microembolisms from the material covering the equipment inserted into the vessel – hydrophilic polymer coating (HPC)[4]. We present an interesting case of HPC revealed in coronary vessels within myocardial preparations taken in forensic post-mortem examination conducted at the Department of Forensic Medicine in Bydgoszcz (L.dz. 676/19). This article raises the issue of clinical implications and forensic aspects.","PeriodicalId":134659,"journal":{"name":"Archives of Forensic Medicine and Criminology","volume":"6 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Forensic Medicine and Criminology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4467/16891716amsik.23.014.18689","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The most common complications of percutaneous coronary interventions and other endovascular procedures include minor hemorrhage, hematoma, or infection at the insertion site [1]. Much more serious ones include damage to the vessel wall, dissection, shock from contrast administration, acute kidney injury, myocardial infarction [2] and ischemic stroke [3]. Ischemic complications can be caused by an embolic incident due to a thrombus formation or detachment of atherosclerotic plaque fragments [3]. A rarely diagnosed complication is ischemia caused by microembolisms from the material covering the equipment inserted into the vessel – hydrophilic polymer coating (HPC)[4]. We present an interesting case of HPC revealed in coronary vessels within myocardial preparations taken in forensic post-mortem examination conducted at the Department of Forensic Medicine in Bydgoszcz (L.dz. 676/19). This article raises the issue of clinical implications and forensic aspects.