Experimental investigations of steel cold-formed moment-resisting bolted lap joints under monotonic and cyclic loading

IF 1.1 Q3 ENGINEERING, CIVIL
Rafał Budziński, L. Ślęczka
{"title":"Experimental investigations of steel cold-formed moment-resisting bolted lap joints under monotonic and cyclic loading","authors":"Rafał Budziński, L. Ślęczka","doi":"10.24425/ace.2023.147664","DOIUrl":null,"url":null,"abstract":": Jointsincold-formedsteelframingstructuresareusuallydesignedasboltedlaptypeoneswith a gusset plate. Unlike the end-plate joints in hot-rolled structures, the load in such joints is transferred through shearing of the bolts and bearing of the material. The prediction of their structural properties maybeproblematicinviewofunfavourableinfluenceoftheholeclearanceandholeovalizationresulting from low bearing resistance of thin walls. A few experimental programmes showed that these issues lead to a different behaviour of the whole joint comparing to common end plate type. These concerns may be particularly important for joints under variable loading, which are prone to deterioration of structural properties. The testing programme conducted by the authors was focused on their behaviour under monotonic and cyclic loading with attention to a potential drop of resistance and stiffness. Monotonic tests revealed quite similar course of the joints’ response. In view of high deformability of the specimens at the intermediate stage of each monotonic test, plastic moment resistances of joints were associated with the initial part of the moment-rotation curves and were multiple times lower than maximum moments obtained in the experiments. The quantities of deterioration of structural properties were determined based on cyclic tests. Drop of resistance and stiffness was observed for several levels of loading range, but the trend of decrease varied for each property. Application of the DIC technique allowed one to identify qualitatively and quantitatively the sources of joint deformability.","PeriodicalId":45753,"journal":{"name":"Archives of Civil Engineering","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/ace.2023.147664","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

: Jointsincold-formedsteelframingstructuresareusuallydesignedasboltedlaptypeoneswith a gusset plate. Unlike the end-plate joints in hot-rolled structures, the load in such joints is transferred through shearing of the bolts and bearing of the material. The prediction of their structural properties maybeproblematicinviewofunfavourableinfluenceoftheholeclearanceandholeovalizationresulting from low bearing resistance of thin walls. A few experimental programmes showed that these issues lead to a different behaviour of the whole joint comparing to common end plate type. These concerns may be particularly important for joints under variable loading, which are prone to deterioration of structural properties. The testing programme conducted by the authors was focused on their behaviour under monotonic and cyclic loading with attention to a potential drop of resistance and stiffness. Monotonic tests revealed quite similar course of the joints’ response. In view of high deformability of the specimens at the intermediate stage of each monotonic test, plastic moment resistances of joints were associated with the initial part of the moment-rotation curves and were multiple times lower than maximum moments obtained in the experiments. The quantities of deterioration of structural properties were determined based on cyclic tests. Drop of resistance and stiffness was observed for several levels of loading range, but the trend of decrease varied for each property. Application of the DIC technique allowed one to identify qualitatively and quantitatively the sources of joint deformability.
单调和循环荷载下钢制冷弯矩抵抗螺栓搭接接头的实验研究
:冷弯型钢框架结构的接缝通常设计为带夹板的螺栓搭接式接缝。与热轧结构中的端板连接不同,这种连接中的荷载是通过螺栓的剪切和材料的承载来传递的。由于薄壁的承载阻力较低,对孔隙和孔蚀产生不利影响,因此对其结构特性的预测可能存在问题。一些实验项目表明,与普通端板类型相比,这些问题会导致整个连接的行为不同。这些问题对于承受可变荷载的接头尤为重要,因为这种接头的结构性能很容易恶化。作者进行的测试项目侧重于单调和循环荷载下的性能,并关注潜在的阻力和硬度下降。单调测试显示接头的反应过程非常相似。由于试样在每次单调试验的中间阶段变形较大,接头的塑性力矩阻力与力矩-旋转曲线的初始部分有关,比试验中获得的最大力矩低数倍。根据循环试验确定了结构性能退化的数量。在几级加载范围内观察到了阻力和刚度的下降,但每种属性的下降趋势各不相同。应用 DIC 技术可以定性和定量地确定连接变形的来源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Archives of Civil Engineering
Archives of Civil Engineering ENGINEERING, CIVIL-
CiteScore
1.50
自引率
28.60%
发文量
0
审稿时长
24 weeks
期刊介绍: ARCHIVES OF CIVIL ENGINEERING publish original papers of the theoretical, experimental, numerical and practical nature in the fields of structural mechanics, soil mechanics and foundations engineering, concrete, metal, timber and composite polymer structures, hydrotechnical structures, roads, railways and bridges, building services, building physics, management in construction, production of construction materials, construction of civil engineering structures, education of civil engineers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信