The feasibility study of stress position device simulating standing weight-bearing applied in computed tomography examination.

IF 1.6 4区 医学
Qiang Zhao, Yuhao Zhang, Xiaohui Gu
{"title":"The feasibility study of stress position device simulating standing weight-bearing applied in computed tomography examination.","authors":"Qiang Zhao, Yuhao Zhang, Xiaohui Gu","doi":"10.1177/10225536231219976","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In order to simulate weight-bearing Computed Tomography (CT) examination, this study designed a simple stress position device. By analyzing the relevant data of stress position footprints and weight-bearing position footprints, the feasibility of the stress position device to simulate standing weight-bearing was verified.</p><p><strong>Methods: </strong>This study randomly selected 25 volunteers for standing weight-bearing and stress position footprints collection, and measured the relevant indicators of stress position footprints and standing weight-bearing position footprints. Two foot and ankle surgeons conducted two measurements respectively on the footprints. Intra-observer and inter-observer reliability were calculated using intra-class correlation coefficients (ICC). Pearson correlation coefficient, ICC, scatter plot analysis, and paired <i>t</i>-test were used to analyze the stress and weight-bearing position data.</p><p><strong>Results: </strong>The intra-observer and inter-observer measurement values were reliable. There was a certain degree of correlation between the stress position footprints and weight-bearing position footprints in terms of Pearson correlation coefficient, ICC, and scatter plot analysis. Paired t-tests showed significant differences in Clarke angle (t 2.636, <i>p</i> .012), C-S index (t 10.568, <i>p</i> .000), arch indx (t 2.176, <i>p</i> .035), and arch lower angle (t 6.246, <i>p</i> .000).</p><p><strong>Conclusion: </strong>The stress position device can generate a certain degree of stress, and after further optimization and improvement of the stress position device, it is feasible to apply it to weight-bearing CT examination in clinical settings.</p>","PeriodicalId":16608,"journal":{"name":"Journal of Orthopaedic Surgery","volume":"31 3","pages":"10225536231219976"},"PeriodicalIF":1.6000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536231219976","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: In order to simulate weight-bearing Computed Tomography (CT) examination, this study designed a simple stress position device. By analyzing the relevant data of stress position footprints and weight-bearing position footprints, the feasibility of the stress position device to simulate standing weight-bearing was verified.

Methods: This study randomly selected 25 volunteers for standing weight-bearing and stress position footprints collection, and measured the relevant indicators of stress position footprints and standing weight-bearing position footprints. Two foot and ankle surgeons conducted two measurements respectively on the footprints. Intra-observer and inter-observer reliability were calculated using intra-class correlation coefficients (ICC). Pearson correlation coefficient, ICC, scatter plot analysis, and paired t-test were used to analyze the stress and weight-bearing position data.

Results: The intra-observer and inter-observer measurement values were reliable. There was a certain degree of correlation between the stress position footprints and weight-bearing position footprints in terms of Pearson correlation coefficient, ICC, and scatter plot analysis. Paired t-tests showed significant differences in Clarke angle (t 2.636, p .012), C-S index (t 10.568, p .000), arch indx (t 2.176, p .035), and arch lower angle (t 6.246, p .000).

Conclusion: The stress position device can generate a certain degree of stress, and after further optimization and improvement of the stress position device, it is feasible to apply it to weight-bearing CT examination in clinical settings.

在计算机断层扫描检查中应用模拟站立负重的压力位置装置的可行性研究。
背景:为了模拟负重计算机断层扫描(CT)检查,本研究设计了一种简单的受力体位装置。通过分析压力体位脚印和负重体位脚印的相关数据,验证了压力体位装置模拟站立负重的可行性:本研究随机选取了 25 名志愿者进行站立负重和受力体位脚印采集,并测量了受力体位脚印和站立负重体位脚印的相关指标。两名足踝外科医生分别对脚印进行了两次测量。采用类内相关系数(ICC)计算观察者内和观察者间的可靠性。使用皮尔逊相关系数、ICC、散点图分析和配对 t 检验分析应力和负重位置数据:结果:观察者内部和观察者之间的测量值是可靠的。从皮尔逊相关系数、ICC 和散点图分析来看,受力位置足迹和负重位置足迹之间存在一定程度的相关性。配对 t 检验显示,Clarke 角(t 2.636,p .012)、C-S 指数(t 10.568,p .000)、足弓内角(t 2.176,p .035)和足弓下角(t 6.246,p .000)存在显著差异:应力体位仪能产生一定程度的应力,在对应力体位仪进行进一步优化和改进后,将其应用于临床负重 CT 检查是可行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
91
期刊介绍: Journal of Orthopaedic Surgery is an open access peer-reviewed journal publishing original reviews and research articles on all aspects of orthopaedic surgery. It is the official journal of the Asia Pacific Orthopaedic Association. The journal welcomes and will publish materials of a diverse nature, from basic science research to clinical trials and surgical techniques. The journal encourages contributions from all parts of the world, but special emphasis is given to research of particular relevance to the Asia Pacific region.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信