[Evaluating skin tolerance. Study of skin cleansing agents in modifications of the Duhring chamber test].

J Kresken, J Eckert, S W Wassilew
{"title":"[Evaluating skin tolerance. Study of skin cleansing agents in modifications of the Duhring chamber test].","authors":"J Kresken,&nbsp;J Eckert,&nbsp;S W Wassilew","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Towards Elucidation of the Problems of Skin-compatibility Testing/An investigation of hand-cleansing products using a modified Duhring chamber test The irritant potential of commercially available liquid syndets was investigated in a repetitive Duhring chamber test using a modified test procedure. Instead of regularly testing over a period of five days, the test was conducted only as long as it took for the first signs of irritation to appear. Among those products tested, substantial differences were found with respect to irritation and possible application time, and, as a result, to skin compatibility. Some of them produced skin irritation with the same intensity and just as quickly as the control substance, sodium lauryl sulfate (0.5%). These differences are not observed in a simple 24-hour epicutaneous test. For this reason, the latter, as opposed to the repetitive Duhring chamber test, appears to be unsuitable for comparative skin compatibility studies of syndets. The skin compatibility of special hand cleaners containing solvents was also investigated in a modified Duhring chamber test. In addition to the modification introduced above for the liquid syndets, here the maximum cumulative application time was reduced from 48 to 30 h. In this manner different degrees of skin compatibility to various special hand cleaners can be ascertained and taken into account when developing new products.</p>","PeriodicalId":11073,"journal":{"name":"Dermatosen in Beruf und Umwelt. Occupation and environment","volume":"37 2","pages":"63-6"},"PeriodicalIF":0.0000,"publicationDate":"1989-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dermatosen in Beruf und Umwelt. Occupation and environment","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Towards Elucidation of the Problems of Skin-compatibility Testing/An investigation of hand-cleansing products using a modified Duhring chamber test The irritant potential of commercially available liquid syndets was investigated in a repetitive Duhring chamber test using a modified test procedure. Instead of regularly testing over a period of five days, the test was conducted only as long as it took for the first signs of irritation to appear. Among those products tested, substantial differences were found with respect to irritation and possible application time, and, as a result, to skin compatibility. Some of them produced skin irritation with the same intensity and just as quickly as the control substance, sodium lauryl sulfate (0.5%). These differences are not observed in a simple 24-hour epicutaneous test. For this reason, the latter, as opposed to the repetitive Duhring chamber test, appears to be unsuitable for comparative skin compatibility studies of syndets. The skin compatibility of special hand cleaners containing solvents was also investigated in a modified Duhring chamber test. In addition to the modification introduced above for the liquid syndets, here the maximum cumulative application time was reduced from 48 to 30 h. In this manner different degrees of skin compatibility to various special hand cleaners can be ascertained and taken into account when developing new products.

评估皮肤耐受性。杜林试验中皮肤清洗剂的改良研究[j]。
对皮肤相容性测试问题的阐明/使用改进的杜林室试验对洗手产品的调查市售液体syndets的刺激潜力进行了研究,使用改进的测试程序在重复的杜林室试验中进行。与常规的为期五天的测试不同,该测试只在出现第一个刺激迹象之前进行。在这些被测试的产品中,在刺激性和可能的使用时间以及皮肤相容性方面发现了实质性的差异。其中一些产生皮肤刺激的强度和速度与对照物质十二烷基硫酸钠(0.5%)相同。在简单的24小时表皮试验中未观察到这些差异。由于这个原因,后者,而不是重复杜林室试验,似乎不适合比较皮肤相容性研究的综合征。在改进的杜林室试验中,还研究了含溶剂的专用洗手液的皮肤相容性。除了上述针对液体清洁剂的修改外,最大累积使用时间从48小时减少到30小时。通过这种方式,可以确定不同程度的皮肤与各种特殊洗手液的相容性,并在开发新产品时考虑到这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信