Effect of supply voltage variations on single-phase capacitor clamped multilevel inverter fed induction motor drive

G. C. Diyoke, C. Eya
{"title":"Effect of supply voltage variations on single-phase capacitor clamped multilevel inverter fed induction motor drive","authors":"G. C. Diyoke, C. Eya","doi":"10.11591/ijape.v12.i4.pp408-415","DOIUrl":null,"url":null,"abstract":"This article presents the effect of supply voltage variations on single-phase capacitor-clamped multilevel inverter-fed induction motor drives. This research is tailored at determining the best torque value and speed to attain a stable state under input voltage variation and minimum time response to realize low percentage harmonic distortions. The effect of constant power quality disturbance harms the performance and behavior of asynchronous motors based on harmonic contents and other energy source integrations. The multilevel inverter has shown good performance in motor drives. This paper deals with the effect of input voltage variations on a single-phase multilevel capacitor-clamped inverter for asynchronous induction motor drives. A five-level capacitor-clamped inverter with an in-phase disposition pulse width modulation technique is adopted. Four high-frequency triangular carrier signals are generated and compared with a reference sinusoidal signal. As a result of this approach, the inverter switches firing signals are generated. The open-loop model is designed and simulated utilizing MATLAB/Simulink and results based on different values of supply voltage are presented. The current and voltage total harmonic distortions (THDs) obtained are 4.97% and 4.46% respectively at the best operating voltage of 400 V and at maximum torque of 47 Nm.","PeriodicalId":340072,"journal":{"name":"International Journal of Applied Power Engineering (IJAPE)","volume":"102 22","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering (IJAPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/ijape.v12.i4.pp408-415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This article presents the effect of supply voltage variations on single-phase capacitor-clamped multilevel inverter-fed induction motor drives. This research is tailored at determining the best torque value and speed to attain a stable state under input voltage variation and minimum time response to realize low percentage harmonic distortions. The effect of constant power quality disturbance harms the performance and behavior of asynchronous motors based on harmonic contents and other energy source integrations. The multilevel inverter has shown good performance in motor drives. This paper deals with the effect of input voltage variations on a single-phase multilevel capacitor-clamped inverter for asynchronous induction motor drives. A five-level capacitor-clamped inverter with an in-phase disposition pulse width modulation technique is adopted. Four high-frequency triangular carrier signals are generated and compared with a reference sinusoidal signal. As a result of this approach, the inverter switches firing signals are generated. The open-loop model is designed and simulated utilizing MATLAB/Simulink and results based on different values of supply voltage are presented. The current and voltage total harmonic distortions (THDs) obtained are 4.97% and 4.46% respectively at the best operating voltage of 400 V and at maximum torque of 47 Nm.
电源电压变化对单相电容箝位多电平逆变器驱动感应电机的影响
本文介绍了电源电压变化对单相电容箝位多电平变频感应电动机驱动的影响。本研究旨在确定最佳转矩值和转速,以在输入电压变化和最小时间响应下达到稳定状态,从而实现低百分比谐波畸变。基于谐波含量和其他能量源的综合,恒定电能质量扰动对异步电动机性能和行为的影响是不可忽视的。该多电平逆变器在电机驱动中表现出良好的性能。研究了输入电压变化对异步异步电动机驱动的单相多电平电容箝位逆变器的影响。采用同相配置脉宽调制技术的五电平电容箝位逆变器。生成四个高频三角形载波信号,并与参考正弦信号进行比较。由于这种方法,逆变器开关触发信号产生。利用MATLAB/Simulink设计并仿真了该系统的开环模型,给出了不同电压值下的结果。在最佳工作电压为400 V、最大转矩为47 Nm时,得到的电流和电压总谐波畸变(THDs)分别为4.97%和4.46%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信