The Relation Between Oxygen Saturation Measured by Pulse Oximetry vs Near-infrared Spectroscopy Following Surfactant Therapy in Very Low-birth-weight Neonates
Maryam Veisizadeh, Seyed Abolfazl Afjehi, M. Zarkesh, Mohammad Kazemian, Ahmad Shafaeizadeh, Leila Khedmat
{"title":"The Relation Between Oxygen Saturation Measured by Pulse Oximetry vs Near-infrared Spectroscopy Following Surfactant Therapy in Very Low-birth-weight Neonates","authors":"Maryam Veisizadeh, Seyed Abolfazl Afjehi, M. Zarkesh, Mohammad Kazemian, Ahmad Shafaeizadeh, Leila Khedmat","doi":"10.5812/ijp-140078","DOIUrl":null,"url":null,"abstract":"Background: Monitoring regional cerebral oxygen saturation (rScO2) and hemodynamic stability (eg, mean arterial blood pressure [MABP]) in high-risk premature infants is crucial to enhance daily clinical practices in neonatal intensive care units (NICUs). Objectives: This study aimed to investigate potential differences between oxygen saturation measurements obtained via near-infrared spectroscopy (NIRS) and pulse oximetry (PO). Methods: This pilot study enrolled 20 very low-birth-weight (VLBW) premature neonates through a non-random, available sampling approach. We gathered maternal and fetal demographic data along with clinical characteristics of the neonates. The study focused on assessing tissue and cerebral oxygenation using PO and NIRS. We specifically monitored changes in mean rScO2 and MABP at various time points: before, during, and 5 and 10 min after the administration of surfactant injection (SI) via the endotracheal tube. Results: The mean gestational age, neonatal birth weight, and Apgar scores at 1 and 5 min after birth were 28.44 ± 2.57 weeks, 1063 ± 246 g, 6.05 ± 2.57, and 7.94 ± 1.79, respectively. No significant differences were observed between mean rScO2 values measured by NIRS and PO before (P = 0.631), during (P = 0.722), and 5 min after (P = 0.783) SI. However, a significant difference between PO and NIRS-based rScO2 values was found 10 min after SI (96.95% vs 75.0%; P = 0.04). Additionally, there was no significant correlation between mean rScO2 and MABP recorded before, during, and after SI. Conclusions: There were no differences in oxygen saturation measurements (recorded by PO) and rScO2 values (recorded by NIRS) before, during, and immediately after SI. Therefore, using PO in NICUs to assess cerebral oxygenation, autoregulation, and hypoxia appears both reasonable and cost-effective. Further multicenter studies are needed to validate the practical advantages and cost-effectiveness of NIRS as an emerging monitoring system.","PeriodicalId":14593,"journal":{"name":"Iranian Journal of Pediatrics","volume":"111 9","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Pediatrics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5812/ijp-140078","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Monitoring regional cerebral oxygen saturation (rScO2) and hemodynamic stability (eg, mean arterial blood pressure [MABP]) in high-risk premature infants is crucial to enhance daily clinical practices in neonatal intensive care units (NICUs). Objectives: This study aimed to investigate potential differences between oxygen saturation measurements obtained via near-infrared spectroscopy (NIRS) and pulse oximetry (PO). Methods: This pilot study enrolled 20 very low-birth-weight (VLBW) premature neonates through a non-random, available sampling approach. We gathered maternal and fetal demographic data along with clinical characteristics of the neonates. The study focused on assessing tissue and cerebral oxygenation using PO and NIRS. We specifically monitored changes in mean rScO2 and MABP at various time points: before, during, and 5 and 10 min after the administration of surfactant injection (SI) via the endotracheal tube. Results: The mean gestational age, neonatal birth weight, and Apgar scores at 1 and 5 min after birth were 28.44 ± 2.57 weeks, 1063 ± 246 g, 6.05 ± 2.57, and 7.94 ± 1.79, respectively. No significant differences were observed between mean rScO2 values measured by NIRS and PO before (P = 0.631), during (P = 0.722), and 5 min after (P = 0.783) SI. However, a significant difference between PO and NIRS-based rScO2 values was found 10 min after SI (96.95% vs 75.0%; P = 0.04). Additionally, there was no significant correlation between mean rScO2 and MABP recorded before, during, and after SI. Conclusions: There were no differences in oxygen saturation measurements (recorded by PO) and rScO2 values (recorded by NIRS) before, during, and immediately after SI. Therefore, using PO in NICUs to assess cerebral oxygenation, autoregulation, and hypoxia appears both reasonable and cost-effective. Further multicenter studies are needed to validate the practical advantages and cost-effectiveness of NIRS as an emerging monitoring system.
期刊介绍:
Iranian Journal of Pediatrics (Iran J Pediatr) is a peer-reviewed medical publication. The purpose of Iran J Pediatr is to increase knowledge, stimulate research in all fields of Pediatrics, and promote better management of pediatric patients. To achieve the goals, the journal publishes basic, biomedical, and clinical investigations on prevalent diseases relevant to pediatrics. The acceptance criteria for all papers are the quality and originality of the research and their significance to our readership. Except where otherwise stated, manuscripts are peer-reviewed by minimum three anonymous reviewers. The Editorial Board reserves the right to refuse any material for publication and advises that authors should retain copies of submitted manuscripts and correspondence as the material cannot be returned. Final acceptance or rejection rests with the Editors.