Measuring Heart Rate Accurately in Patients With Parkinson Disease During Intense Exercise: Usability Study of Fitbit Charge 4

Giulia Colonna, Jocelyn Hoye, Bart de Laat, Gelsina Stanley, Alaaddin Ibrahimy, S. Tinaz, Evan D. Morris
{"title":"Measuring Heart Rate Accurately in Patients With Parkinson Disease During Intense Exercise: Usability Study of Fitbit Charge 4","authors":"Giulia Colonna, Jocelyn Hoye, Bart de Laat, Gelsina Stanley, Alaaddin Ibrahimy, S. Tinaz, Evan D. Morris","doi":"10.2196/51515","DOIUrl":null,"url":null,"abstract":"\n \n Parkinson disease (PD) is the second most common neurodegenerative disease, affecting approximately 1% of the world’s population.\nIncreasing evidence suggests that aerobic physical exercise can be beneficial in mitigating both motor and nonmotor symptoms of the disease.\nIn a recent pilot study of the role of exercise on PD, we sought to confirm exercise intensity by monitoring heart rate (HR). For this purpose, we asked participants to wear a chest strap HR monitor (Polar Electro Oy) and the Fitbit Charge 4 (Fitbit Inc) wrist-worn HR monitor as a potential proxy due to its convenience.\nPolar H10 has been shown to provide highly accurate R-R interval measurements. Therefore, we treated it as the gold standard in this study. It has been shown that Fitbit Charge 4 has comparable accuracy to Polar H10 in healthy participants. It has yet to be determined if the Fitbit is as accurate as Polar H10 in patients with PD during rest and exercise.\n \n \n \n This study aimed to compare Fitbit Charge 4 to Polar H10 for monitoring HR in patients with PD at rest and during an intensive exercise program.\n \n \n \n A total of 596 exercise sessions from 11 (6 male and 5 female) participants were collected simultaneously with both devices. Patients with early-stage PD (Hoehn and Yahr ≤2) were enrolled in a 6-month exercise program designed for patients with PD. They participated in 3 one-hour exercise sessions per week. They wore both Fitbit and Polar H10 during each session. Sessions included rest, warm-up, intense exercise, and cool-down periods.\nWe calculated the bias in the HR of the Fitbit Charge 4 at rest (5 min) and during intense exercise (20 min) by comparing the mean HR during each of the periods to the respective means measured by Polar H10 (HRFitbit – HRPolar). We also measured the sensitivity and specificity of Fitbit Charge 4 to detect average HRs that exceed the threshold for intensive exercise, defined as 70% of an individual’s theoretical maximum HR. Different types of correlations between the 2 devices were investigated.\n \n \n \n The mean bias was 1.68 beats per minute (bpm) at rest and 6.29 bpm during high-intensity exercise, with an overestimation by Fitbit Charge 4 in both conditions. The mean bias of the Fitbit across both rest and intensive exercise periods was 3.98 bpm. The device’s sensitivity in identifying high-intensity exercise sessions was 97.14%. The correlation between the 2 devices was nonlinear, suggesting Fitbit’s tendency to saturate at high values of HR.\n \n \n \n The performance of Fitbit Charge 4 is comparable to Polar H10 for assessing exercise intensity in a cohort of patients with PD (mean bias 3.98 bpm). The device could be considered a reasonable surrogate for more cumbersome chest-worn devices in future studies of clinical cohorts.\n","PeriodicalId":87288,"journal":{"name":"JMIR biomedical engineering","volume":"48 48","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/51515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Parkinson disease (PD) is the second most common neurodegenerative disease, affecting approximately 1% of the world’s population. Increasing evidence suggests that aerobic physical exercise can be beneficial in mitigating both motor and nonmotor symptoms of the disease. In a recent pilot study of the role of exercise on PD, we sought to confirm exercise intensity by monitoring heart rate (HR). For this purpose, we asked participants to wear a chest strap HR monitor (Polar Electro Oy) and the Fitbit Charge 4 (Fitbit Inc) wrist-worn HR monitor as a potential proxy due to its convenience. Polar H10 has been shown to provide highly accurate R-R interval measurements. Therefore, we treated it as the gold standard in this study. It has been shown that Fitbit Charge 4 has comparable accuracy to Polar H10 in healthy participants. It has yet to be determined if the Fitbit is as accurate as Polar H10 in patients with PD during rest and exercise. This study aimed to compare Fitbit Charge 4 to Polar H10 for monitoring HR in patients with PD at rest and during an intensive exercise program. A total of 596 exercise sessions from 11 (6 male and 5 female) participants were collected simultaneously with both devices. Patients with early-stage PD (Hoehn and Yahr ≤2) were enrolled in a 6-month exercise program designed for patients with PD. They participated in 3 one-hour exercise sessions per week. They wore both Fitbit and Polar H10 during each session. Sessions included rest, warm-up, intense exercise, and cool-down periods. We calculated the bias in the HR of the Fitbit Charge 4 at rest (5 min) and during intense exercise (20 min) by comparing the mean HR during each of the periods to the respective means measured by Polar H10 (HRFitbit – HRPolar). We also measured the sensitivity and specificity of Fitbit Charge 4 to detect average HRs that exceed the threshold for intensive exercise, defined as 70% of an individual’s theoretical maximum HR. Different types of correlations between the 2 devices were investigated. The mean bias was 1.68 beats per minute (bpm) at rest and 6.29 bpm during high-intensity exercise, with an overestimation by Fitbit Charge 4 in both conditions. The mean bias of the Fitbit across both rest and intensive exercise periods was 3.98 bpm. The device’s sensitivity in identifying high-intensity exercise sessions was 97.14%. The correlation between the 2 devices was nonlinear, suggesting Fitbit’s tendency to saturate at high values of HR. The performance of Fitbit Charge 4 is comparable to Polar H10 for assessing exercise intensity in a cohort of patients with PD (mean bias 3.98 bpm). The device could be considered a reasonable surrogate for more cumbersome chest-worn devices in future studies of clinical cohorts.
准确测量帕金森病患者在剧烈运动时的心率:Fitbit Charge 4 的可用性研究
帕金森病(PD)是第二大最常见的神经退行性疾病,影响约1%的世界人口。越来越多的证据表明,有氧体育锻炼可以减轻疾病的运动和非运动症状。在最近的一项关于运动对PD的作用的初步研究中,我们试图通过监测心率(HR)来确认运动强度。为此,我们要求参与者佩戴胸带式人力资源监测器(Polar Electro Oy)和Fitbit Charge 4 (Fitbit Inc)腕带式人力资源监测器作为潜在的替代品,因为它很方便。Polar H10已被证明可以提供高度精确的R-R区间测量。因此,我们将其作为本研究的金标准。研究表明,Fitbit Charge 4在健康参与者中的准确性与Polar H10相当。在PD患者休息和运动时,Fitbit是否和Polar H10一样准确还有待确定。本研究旨在比较Fitbit Charge 4和Polar H10在PD患者休息和强化锻炼期间监测HR的效果。同时收集了11名参与者(6名男性和5名女性)的596次运动记录。早期PD患者(Hoehn和Yahr≤2)被纳入为PD患者设计的为期6个月的运动计划。他们每周参加三次一小时的锻炼。他们每次都戴着Fitbit和Polar H10。疗程包括休息、热身、剧烈运动和冷静期。通过将每个时间段的平均HR与Polar H10 (HRFitbit - HRPolar)测量的各自平均值进行比较,我们计算了Fitbit Charge 4在休息(5分钟)和剧烈运动(20分钟)时的HR偏差。我们还测量了Fitbit Charge 4的灵敏度和特异性,以检测超过高强度运动阈值的平均HR,定义为个人理论最大HR的70%。研究了两种器件之间不同类型的相关性。休息时的平均偏差为每分钟1.68次,高强度运动时的平均偏差为每分钟6.29次,在这两种情况下,Fitbit Charge 4都高估了这一偏差。Fitbit在休息和剧烈运动期间的平均偏差为每分钟3.98次。该设备识别高强度运动的灵敏度为97.14%。两种设备之间的相关性是非线性的,表明Fitbit倾向于在高HR值时饱和。Fitbit Charge 4在评估PD患者队列运动强度方面的表现与Polar H10相当(平均偏差3.98 bpm)。在未来的临床队列研究中,该设备可以被认为是更笨重的胸戴设备的合理替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信