Impact of cord clamping on haemodynamic transition in term newborn infants

Roberto Chioma, Daragh Finn, David B Healy, Ita Herlihy, Vicki Livingstone, Jurate Panaviene, Eugene M Dempsey
{"title":"Impact of cord clamping on haemodynamic transition in term newborn infants","authors":"Roberto Chioma, Daragh Finn, David B Healy, Ita Herlihy, Vicki Livingstone, Jurate Panaviene, Eugene M Dempsey","doi":"10.1136/archdischild-2023-325652","DOIUrl":null,"url":null,"abstract":"Objective To assess the haemodynamic consequences of cord clamping (CC) in healthy term infants. Design Cohort study. Setting Tertiary maternity hospital. Patients 46 full-term vigorous infants born by caesarean section. Interventions Echocardiography was performed before CC, immediately after CC and at 5 min after birth. Main outcome measures Pulsed wave Doppler-derived cardiac output and the pulmonary artery acceleration time indexed to the right ventricle ejection time were obtained. As markers of loading fluctuations, the myocardial performance indexes and the velocities of the tricuspid and mitral valve annuli were determined with tissue Doppler imaging. Heart rate was derived from Doppler imaging throughout the assessments. Results Left ventricular output increased throughout the first minutes after birth (mean (SD) 222.4 (32.5) mL/kg/min before CC vs 239.7 (33.6) mL/kg/min at 5 min, p=0.01), while right ventricular output decreased (306.5 (48.2) mL/kg/min before vs 272.8 (55.5) mL/kg/min immediately after CC, p=0.001). The loading conditions of both ventricles were transiently impaired by CC, recovering at 5 min. Heart rate progressively decreased after birth, following a linear trend temporarily increased by CC. The variation in left ventricular output across the CC was directly correlated to the fluctuation of left ventricular preload over the same period (p = 0.03). Conclusions This study illustrates the cardiovascular consequences of CC in term vigorous infants and offers insight into the haemodynamic transition from fetal to neonatal circulation in spontaneously breathing newborns. Strategies that aim to enhance left ventricular preload before CC may prevent complications of perinatal cardiovascular imbalance. Data are available on reasonable request. The data that support the findings of this study are available on request from the authors.","PeriodicalId":501153,"journal":{"name":"Fetal & Neonatal","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fetal & Neonatal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/archdischild-2023-325652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To assess the haemodynamic consequences of cord clamping (CC) in healthy term infants. Design Cohort study. Setting Tertiary maternity hospital. Patients 46 full-term vigorous infants born by caesarean section. Interventions Echocardiography was performed before CC, immediately after CC and at 5 min after birth. Main outcome measures Pulsed wave Doppler-derived cardiac output and the pulmonary artery acceleration time indexed to the right ventricle ejection time were obtained. As markers of loading fluctuations, the myocardial performance indexes and the velocities of the tricuspid and mitral valve annuli were determined with tissue Doppler imaging. Heart rate was derived from Doppler imaging throughout the assessments. Results Left ventricular output increased throughout the first minutes after birth (mean (SD) 222.4 (32.5) mL/kg/min before CC vs 239.7 (33.6) mL/kg/min at 5 min, p=0.01), while right ventricular output decreased (306.5 (48.2) mL/kg/min before vs 272.8 (55.5) mL/kg/min immediately after CC, p=0.001). The loading conditions of both ventricles were transiently impaired by CC, recovering at 5 min. Heart rate progressively decreased after birth, following a linear trend temporarily increased by CC. The variation in left ventricular output across the CC was directly correlated to the fluctuation of left ventricular preload over the same period (p = 0.03). Conclusions This study illustrates the cardiovascular consequences of CC in term vigorous infants and offers insight into the haemodynamic transition from fetal to neonatal circulation in spontaneously breathing newborns. Strategies that aim to enhance left ventricular preload before CC may prevent complications of perinatal cardiovascular imbalance. Data are available on reasonable request. The data that support the findings of this study are available on request from the authors.
断脐对足月新生儿血流动力学转换的影响
目的 评估健康足月儿脐带夹闭(CC)对血流动力学的影响。设计 队列研究。地点 三级妇产医院患者 46 名剖腹产足月健壮婴儿。干预措施 在脐带钳夹前、脐带钳夹后立即和出生后 5 分钟进行超声心动图检查。主要结果指标 获得脉冲波多普勒心输出量和肺动脉加速时间与右心室射血时间的指数。作为负荷波动的标记,心肌性能指标以及三尖瓣和二尖瓣瓣环的速度是通过组织多普勒成像测定的。在整个评估过程中,心率都是通过多普勒成像得出的。结果 左心室输出量在出生后最初几分钟内一直增加(CC前平均(标清)222.4(32.5)毫升/千克/分钟 vs 5分钟时239.7(33.6)毫升/千克/分钟,p=0.01),而右心室输出量减少(CC前306.5(48.2)毫升/千克/分钟 vs CC后272.8(55.5)毫升/千克/分钟,p=0.001)。CC 会短暂影响两个心室的负荷条件,5 分钟后恢复。出生后心率逐渐下降,呈线性趋势,CC 会暂时增加心率。CC 期间左心室输出量的变化与同期左心室前负荷的波动直接相关(p = 0.03)。结论 该研究说明了 CC 对足月儿心血管的影响,并有助于了解自主呼吸新生儿从胎儿循环到新生儿循环的血流动力学转变。在 CC 之前提高左心室前负荷的策略可预防围产期心血管失衡的并发症。如有合理要求,可提供相关数据。支持本研究结果的数据可向作者索取。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信