Implementation of white analytical chemistry-driven analytical quality risk assessment and design of experiments to multipurpose chromatographic method for the synchronous estimation of multiple drugs co-formulated with paracetamol

IF 1.1 4区 化学 Q4 CHEMISTRY, ANALYTICAL
Pintu Prajapati, Minal Salunkhe, Veerashakar Pulusu, Shailesh Shah
{"title":"Implementation of white analytical chemistry-driven analytical quality risk assessment and design of experiments to multipurpose chromatographic method for the synchronous estimation of multiple drugs co-formulated with paracetamol","authors":"Pintu Prajapati, Minal Salunkhe, Veerashakar Pulusu, Shailesh Shah","doi":"10.1007/s00764-023-00262-z","DOIUrl":null,"url":null,"abstract":"<p>In the pharmaceutical industry, several fixed-dose paracetamol combinations have been manufactured and marketed. Several chromatographic methods have been documented in the literature for the quality control of these fixed-dose combinations (FDCs). Yet, these chromatographic procedures were developed using teratogenic and neurotoxic organic solvents that are harmful to the environment and dangerous to human and animal life. As a result, a multipurpose chromatographic technique was developed combining principles of white analytical chemistry, quality risk assessment, and experimental design. To reduce the time and cost of analysis, this chromatographic method needs a single chromatographic condition for the quality control of multiple FDCs of paracetamol. To safeguard the environment and human life, the suggested chromatographic process employs low-toxicity possible solvents. The analytical quality risk assessment methodology by Placket‒Burman design was used to identify significant analytical method risk parameters and analytical quality attributes. Response surface analysis by mixture design was used to optimize the identified critical method risk parameters. Using unique principles of white analytical chemistry, the proposed and published chromatographic techniques were assessed for their validation efficiency, greenness profile, time efficiency, and cost efficiency for the estimation of FDCs of paracetamol with multiple drugs.</p>","PeriodicalId":17616,"journal":{"name":"Jpc-journal of Planar Chromatography-modern Tlc","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jpc-journal of Planar Chromatography-modern Tlc","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00764-023-00262-z","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In the pharmaceutical industry, several fixed-dose paracetamol combinations have been manufactured and marketed. Several chromatographic methods have been documented in the literature for the quality control of these fixed-dose combinations (FDCs). Yet, these chromatographic procedures were developed using teratogenic and neurotoxic organic solvents that are harmful to the environment and dangerous to human and animal life. As a result, a multipurpose chromatographic technique was developed combining principles of white analytical chemistry, quality risk assessment, and experimental design. To reduce the time and cost of analysis, this chromatographic method needs a single chromatographic condition for the quality control of multiple FDCs of paracetamol. To safeguard the environment and human life, the suggested chromatographic process employs low-toxicity possible solvents. The analytical quality risk assessment methodology by Placket‒Burman design was used to identify significant analytical method risk parameters and analytical quality attributes. Response surface analysis by mixture design was used to optimize the identified critical method risk parameters. Using unique principles of white analytical chemistry, the proposed and published chromatographic techniques were assessed for their validation efficiency, greenness profile, time efficiency, and cost efficiency for the estimation of FDCs of paracetamol with multiple drugs.

Abstract Image

实施白色分析化学驱动的分析质量风险评估和实验设计,以多用途色谱法同步估计多种药物共配扑热息痛
在制药业,已经生产和销售了几种固定剂量的扑热息痛组合。几种色谱方法已在文献中记录用于这些固定剂量组合(fdc)的质量控制。然而,这些色谱方法是使用致畸和神经毒性有机溶剂开发的,这些溶剂对环境有害,对人类和动物的生命有危险。因此,结合白色分析化学、质量风险评估和实验设计的原理,开发了一种多用途色谱技术。为了减少分析时间和成本,该色谱方法需要一个单一的色谱条件来控制对乙酰氨基酚的多个fdc的质量。为了保护环境和人类的生命,建议采用低毒性的溶剂。采用Placket-Burman设计的分析性质量风险评价方法,确定了重要的分析方法风险参数和分析质量属性。采用混合设计响应面分析法对识别出的关键方法风险参数进行优化。利用白色分析化学的独特原理,对提出和发表的色谱技术进行了验证效率、绿色度、时间效率和成本效率的评估,以估计对乙酰氨基酚与多种药物的fdc。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.20
自引率
18.80%
发文量
66
审稿时长
>12 weeks
期刊介绍: JPC - Journal of Planar Chromatography - Modern TLC is an international journal devoted exclusively to the publication of research papers on analytical and preparative planar chromatography. The journal covers all fields of planar chromatography, on all kinds of stationary phase (paper, layer, gel) and with various modes of migration of the mobile phase (capillary action or forced flow).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信