Development of a simple high-performance liquid chromatography-ultraviolet detection method for olaparib in patients with ovarian cancer.

IF 1.9 Q3 PHARMACOLOGY & PHARMACY
Drug Discoveries and Therapeutics Pub Date : 2024-01-12 Epub Date: 2023-12-03 DOI:10.5582/ddt.2023.01074
Takeo Yasu, Ryosuke Nishijima, Risa Ikuta, Mikio Shirota, Haruko Iwase
{"title":"Development of a simple high-performance liquid chromatography-ultraviolet detection method for olaparib in patients with ovarian cancer.","authors":"Takeo Yasu, Ryosuke Nishijima, Risa Ikuta, Mikio Shirota, Haruko Iwase","doi":"10.5582/ddt.2023.01074","DOIUrl":null,"url":null,"abstract":"<p><p>Olaparib is a small-molecule inhibitor of poly(ADP)-ribose polymerase (PARP) used as maintenance therapy for recurrent ovarian cancer and newly diagnosed advanced ovarian cancer after initial chemotherapy. An exposure-toxicity correlation has been reported between the probability of anemia, a common adverse event associated with olaparib, and the steady-state minimum plasma concentration (Cmin) as well as the predicted maximum plasma concentration (Cmax). On the other hand, olaparib exhibits high interpatient variability with regard to the area under the concentration-time curve, Cmax, and Cmin. Therefore, we developed a simple and sensitive assay based on high-performance liquid chromatography with ultraviolet light (HPLC-UV) for the therapeutic drug monitoring of olaparib. The analysis was performed on an octadecylsilyl column with a mobile phase consisting of 0.5% KH<sub>2</sub>PO<sub>4</sub> (pH 4.5) and acetonitrile (71:29, v/v), at a flow rate of 0.8 mL/min. Olaparib and an internal standard (imatinib) were well separated from the co-extracted material, with retention times of 13.6 and 11.5 min, respectively. The calibration curve for olaparib showed linearity over the concentration range of 0.10-10.0 μg/mL (r<sup>2</sup> = 0.9998). The intra- and inter- day validation coefficients ranged from 1.79 to 4.13% and 1.37 to 3.55%, respectively. Measurement accuracy ranged from - 6.07 to 3.26%, with a recovery rate of more than 91.06%. The developed method was then applied to evaluate the plasma olaparib concentrations in patients with ovarian cancer. Our findings demonstrate that HPLC-UV is an economical, simple, and sensitive method for clinical application and holds promise for the effective drug monitoring of olaparib during ovarian cancer treatment.</p>","PeriodicalId":47494,"journal":{"name":"Drug Discoveries and Therapeutics","volume":" ","pages":"428-433"},"PeriodicalIF":1.9000,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Discoveries and Therapeutics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5582/ddt.2023.01074","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Olaparib is a small-molecule inhibitor of poly(ADP)-ribose polymerase (PARP) used as maintenance therapy for recurrent ovarian cancer and newly diagnosed advanced ovarian cancer after initial chemotherapy. An exposure-toxicity correlation has been reported between the probability of anemia, a common adverse event associated with olaparib, and the steady-state minimum plasma concentration (Cmin) as well as the predicted maximum plasma concentration (Cmax). On the other hand, olaparib exhibits high interpatient variability with regard to the area under the concentration-time curve, Cmax, and Cmin. Therefore, we developed a simple and sensitive assay based on high-performance liquid chromatography with ultraviolet light (HPLC-UV) for the therapeutic drug monitoring of olaparib. The analysis was performed on an octadecylsilyl column with a mobile phase consisting of 0.5% KH2PO4 (pH 4.5) and acetonitrile (71:29, v/v), at a flow rate of 0.8 mL/min. Olaparib and an internal standard (imatinib) were well separated from the co-extracted material, with retention times of 13.6 and 11.5 min, respectively. The calibration curve for olaparib showed linearity over the concentration range of 0.10-10.0 μg/mL (r2 = 0.9998). The intra- and inter- day validation coefficients ranged from 1.79 to 4.13% and 1.37 to 3.55%, respectively. Measurement accuracy ranged from - 6.07 to 3.26%, with a recovery rate of more than 91.06%. The developed method was then applied to evaluate the plasma olaparib concentrations in patients with ovarian cancer. Our findings demonstrate that HPLC-UV is an economical, simple, and sensitive method for clinical application and holds promise for the effective drug monitoring of olaparib during ovarian cancer treatment.

卵巢癌患者奥拉帕尼的高效液相色谱-紫外检测方法的建立。
奥拉帕尼(Olaparib)是一种小分子聚(ADP)-核糖聚合酶(PARP)抑制剂,用于卵巢癌复发和新诊断的晚期卵巢癌初始化疗后的维持治疗。有报道称,与奥拉帕尼相关的常见不良事件——贫血的概率与稳态最低血浆浓度(Cmin)以及预测最高血浆浓度(Cmax)之间存在暴露-毒性相关性。另一方面,奥拉帕尼在浓度-时间曲线下的面积、Cmax和Cmin方面表现出很高的患者间变异性。为此,建立了一种简便、灵敏的紫外高效液相色谱(HPLC-UV)检测奥拉帕尼治疗药物的方法。色谱柱为十八烷基硅基柱,流动相为0.5% KH2PO4 (pH 4.5)和乙腈(71:29,v/v),流速为0.8 mL/min。奥拉帕尼与内标(伊马替尼)分离较好,保留时间分别为13.6 min和11.5 min。奥拉帕尼在0.10 ~ 10.0 μg/mL范围内线性良好(r2 = 0.9998)。日内验证系数为1.79 ~ 4.13%,日内验证系数为1.37 ~ 3.55%。测定准确度为- 6.07 ~ 3.26%,回收率大于91.06%。然后应用该方法评价卵巢癌患者血浆奥拉帕尼浓度。本研究结果表明,高效液相色谱-紫外分光光度法是一种经济、简便、灵敏的临床应用方法,有望用于卵巢癌治疗期间奥拉帕尼的有效药物监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Drug Discoveries and Therapeutics
Drug Discoveries and Therapeutics PHARMACOLOGY & PHARMACY-
CiteScore
3.20
自引率
3.20%
发文量
51
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信