Correlation and Agreement Between the CO2 Gap Obtained From Peripheral Venous Blood and From Mixed Venous Blood in Mechanically Ventilated Septic Patients.

IF 1.1 Q3 ANESTHESIOLOGY
Daniele Orso, Chiara Molinari, Giacomo Bacchetti, Victor Zanini, Valentina Montanar, Roberto Copetti, Nicola Guglielmo, Tiziana Bove
{"title":"Correlation and Agreement Between the CO2 Gap Obtained From Peripheral Venous Blood and From Mixed Venous Blood in Mechanically Ventilated Septic Patients.","authors":"Daniele Orso, Chiara Molinari, Giacomo Bacchetti, Victor Zanini, Valentina Montanar, Roberto Copetti, Nicola Guglielmo, Tiziana Bove","doi":"10.1177/10892532231219917","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Venous-arterial CO2 difference (Pv-aCO2) is a valuable marker that can identify a subset of patients in shock with inadequate cardiac output to meet tissue metabolic requirements. Some authors have found that Pv-aCO2 levels calculated from mixed vs central venous blood demonstrate a linear relationship. The purpose of this study is to determine whether there is a linear relationship between Pv-aCO2 obtained with peripheral venous blood (Pv-aCO2p) and with mixed venous blood, and the agreement between the 2 measures.</p><p><strong>Methods: </strong>This was a prospective, single-center, observational clinical study enrolling mechanically ventilated patients in septic shock during the first 24 hours following admission to the intensive care unit.</p><p><strong>Results: </strong>The Bravais-Pearson r-coefficient between Pv-aCO2 and Pv-aCO2p was .70 in 38 determinations (95%CI .48-.83; <i>P</i>-value = 1.25 x 10^-6). The Bland-Altman bias was 4.11 mmHg (95%CI 2.82-5.39), and the repeatability coefficient was 11.05. Using the Taffe approach, the differential and proportional biases were 2.81 (95%CI .52-5.11) and 1.29 (95%CI .86-1.72), respectively.</p><p><strong>Conclusion: </strong>There was linear correlation between Pv-aCO2p and Pv-aCO2 in mechanically ventilated patients with septic shock. The bias showed a gradual increase in high Pv-aCO2 values in an upward trend.</p>","PeriodicalId":46500,"journal":{"name":"Seminars in Cardiothoracic and Vascular Anesthesia","volume":" ","pages":"18-27"},"PeriodicalIF":1.1000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Cardiothoracic and Vascular Anesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/10892532231219917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/1 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Venous-arterial CO2 difference (Pv-aCO2) is a valuable marker that can identify a subset of patients in shock with inadequate cardiac output to meet tissue metabolic requirements. Some authors have found that Pv-aCO2 levels calculated from mixed vs central venous blood demonstrate a linear relationship. The purpose of this study is to determine whether there is a linear relationship between Pv-aCO2 obtained with peripheral venous blood (Pv-aCO2p) and with mixed venous blood, and the agreement between the 2 measures.

Methods: This was a prospective, single-center, observational clinical study enrolling mechanically ventilated patients in septic shock during the first 24 hours following admission to the intensive care unit.

Results: The Bravais-Pearson r-coefficient between Pv-aCO2 and Pv-aCO2p was .70 in 38 determinations (95%CI .48-.83; P-value = 1.25 x 10^-6). The Bland-Altman bias was 4.11 mmHg (95%CI 2.82-5.39), and the repeatability coefficient was 11.05. Using the Taffe approach, the differential and proportional biases were 2.81 (95%CI .52-5.11) and 1.29 (95%CI .86-1.72), respectively.

Conclusion: There was linear correlation between Pv-aCO2p and Pv-aCO2 in mechanically ventilated patients with septic shock. The bias showed a gradual increase in high Pv-aCO2 values in an upward trend.

机械通气脓毒症患者外周静脉血与混合静脉血CO2间隙的相关性与一致性
背景:静脉-动脉CO2差(Pv-aCO2)是一种有价值的标志物,可以识别心输出量不足以满足组织代谢需求的休克患者亚群。一些作者发现,混合静脉血和中心静脉血计算出的Pv-aCO2水平呈线性关系。本研究的目的是确定外周静脉血(Pv-aCO2p)和混合静脉血获得的Pv-aCO2是否存在线性关系,以及两者之间的一致性。方法:这是一项前瞻性、单中心、观察性临床研究,纳入重症监护病房入院后24小时内机械通气的感染性休克患者。结果:38项检测中Pv-aCO2与Pv-aCO2p的Bravais-Pearson r系数为0.70 (95%CI为0.48 ~ 0.83;p值= 1.25 x 10^-6)。Bland-Altman偏倚为4.11 mmHg (95%CI 2.82 ~ 5.39),重复性系数为11.05。使用Taffe方法,差异偏差和比例偏差分别为2.81 (95%CI 0.52 -5.11)和1.29 (95%CI 0.86 -1.72)。结论:感染性休克机械通气患者Pv-aCO2p与Pv-aCO2呈线性相关。偏置值显示高Pv-aCO2值呈上升趋势逐渐增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
14.30%
发文量
31
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信