Revisiting Pentacam Parameters in the Diagnosis of Subclinical and Mild Keratoconus Based on Different Grading System Definitions

Q3 Medicine
Turkish Journal of Ophthalmology Pub Date : 2023-12-21 Epub Date: 2023-11-27 DOI:10.4274/tjo.galenos.2023.68188
İbrahim Toprak, Çiğdem Martin, Celal Emre Güneş, Jorge Alio
{"title":"Revisiting Pentacam Parameters in the Diagnosis of Subclinical and Mild Keratoconus Based on Different Grading System Definitions","authors":"İbrahim Toprak, Çiğdem Martin, Celal Emre Güneş, Jorge Alio","doi":"10.4274/tjo.galenos.2023.68188","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To retest the performance of Pentacam parameters in the detection of eyes with subclinical keratoconus (KC) and mild KC based on different definitions from the Amsler-Krumeich (AK), Collaborative Longitudinal Evaluation of Keratoconus (CLEK), and ABCD systems.</p><p><strong>Materials and methods: </strong>This cross-sectional university-based study comprised 24 eyes with subclinical KC, 144 eyes with mild KC (based on AK in 101 eyes, CLEK in 28 eyes, and ABCD in 15 eyes), and 70 controls. Diagnostic ability of the thinnest point (TP) pachymetry, KISA% index, inferior-superior asymmetry, corneal aberrations, Pentacam indices, front/back elevations, pachymetric progression index, Ambrósio-Relational Thickness (ARTmax), and Belin/Ambrósio Enhanced Ectasia Display scores (Df, Db, Dp, Dt, Da, and D-final) were evaluated.</p><p><strong>Results: </strong>ARTmax (83.3% sensitivity/74.3% specificity) had the highest ability in distinguishing subclinical KC from normal, followed by TP pachymetry, Dt, and Da. D-final showed excellent sensitivity/specificity in mild KC diagnosis based on AK (98%/100%) and CLEK (97.4%/100%) descriptions. In the mild KC-ABCD group, index of vertical asymmetry accurately detected all eyes with mild KC and 97.1% of the controls.</p><p><strong>Conclusion: </strong>This study points out the gray zone in the detection of eyes with subclinical and mild KC due to overlapping terminology and grading criteria. Pentacam parameters seem to have modest capability in subclinical KC detection, indicating the necessity for additional diagnostic modalities. However, eyes with mild KC can be diagnosed with high accuracy using Pentacam parameters, although the strongest parameters may vary according to the definition of “mild KC.” Nevertheless, uniform and definitive criteria for subclinical and clinical KC classification are required for a diagnostic and therapeutic consensus in KC.</p>","PeriodicalId":23373,"journal":{"name":"Turkish Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10750093/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/tjo.galenos.2023.68188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To retest the performance of Pentacam parameters in the detection of eyes with subclinical keratoconus (KC) and mild KC based on different definitions from the Amsler-Krumeich (AK), Collaborative Longitudinal Evaluation of Keratoconus (CLEK), and ABCD systems.

Materials and methods: This cross-sectional university-based study comprised 24 eyes with subclinical KC, 144 eyes with mild KC (based on AK in 101 eyes, CLEK in 28 eyes, and ABCD in 15 eyes), and 70 controls. Diagnostic ability of the thinnest point (TP) pachymetry, KISA% index, inferior-superior asymmetry, corneal aberrations, Pentacam indices, front/back elevations, pachymetric progression index, Ambrósio-Relational Thickness (ARTmax), and Belin/Ambrósio Enhanced Ectasia Display scores (Df, Db, Dp, Dt, Da, and D-final) were evaluated.

Results: ARTmax (83.3% sensitivity/74.3% specificity) had the highest ability in distinguishing subclinical KC from normal, followed by TP pachymetry, Dt, and Da. D-final showed excellent sensitivity/specificity in mild KC diagnosis based on AK (98%/100%) and CLEK (97.4%/100%) descriptions. In the mild KC-ABCD group, index of vertical asymmetry accurately detected all eyes with mild KC and 97.1% of the controls.

Conclusion: This study points out the gray zone in the detection of eyes with subclinical and mild KC due to overlapping terminology and grading criteria. Pentacam parameters seem to have modest capability in subclinical KC detection, indicating the necessity for additional diagnostic modalities. However, eyes with mild KC can be diagnosed with high accuracy using Pentacam parameters, although the strongest parameters may vary according to the definition of “mild KC.” Nevertheless, uniform and definitive criteria for subclinical and clinical KC classification are required for a diagnostic and therapeutic consensus in KC.

基于不同分级系统定义的诊断亚临床和轻度圆锥角膜的Pentacam参数重述。
目的:根据Amsler-Krumeich (AK)、圆锥角膜协同纵向评估(CLEK)和ABCD系统的不同定义,重新测试Pentacam参数在检测亚临床圆锥角膜(KC)和轻度圆锥角膜(KC)中的性能。材料和方法:这项以大学为基础的横断面研究包括24只亚临床KC, 144只轻度KC(基于101只AK, 28只CLEK, 15只ABCD)和70只对照。评估最薄点(TP)厚测、KISA%指数、下-上不对称、角膜像差、Pentacam指数、前/后仰角、厚测进展指数、Ambrósio-Relational厚度(ARTmax)和Belin/Ambrósio增强扩张显示评分(Df、Db、Dp、Dt、Da和D-final)的诊断能力。结果:ARTmax(敏感性83.3% /特异性74.3%)区分亚临床KC与正常的能力最高,TP厚测法次之,Dt和Da次之。D-final在基于AK(98%/100%)和CLEK(97.4%/100%)描述的轻度KC诊断中表现出极好的敏感性/特异性。在轻度KC- abcd组中,垂直不对称指数准确检出率为97.1%。结论:本研究指出了由于术语和分级标准的重叠,在亚临床和轻度KC的眼部检测中存在灰色地带。Pentacam参数在亚临床KC检测中似乎具有适度的能力,表明需要额外的诊断方式。然而,使用Pentacam参数可以高精度地诊断轻度KC,尽管根据“轻度KC”的定义,最强参数可能会有所不同。然而,对于KC的诊断和治疗共识,需要统一和明确的亚临床和临床KC分类标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Turkish Journal of Ophthalmology
Turkish Journal of Ophthalmology Medicine-Ophthalmology
CiteScore
2.20
自引率
0.00%
发文量
0
期刊介绍: The Turkish Journal of Ophthalmology (TJO) is the only scientific periodical publication of the Turkish Ophthalmological Association and has been published since January 1929. In its early years, the journal was published in Turkish and French. Although there were temporary interruptions in the publication of the journal due to various challenges, the Turkish Journal of Ophthalmology has been published continually from 1971 to the present. The target audience includes specialists and physicians in training in ophthalmology in all relevant disciplines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信