{"title":"Assessing the Sentimag system for guiding sentinel node biopsies in patients with breast cancer.","authors":"Hira Abidi, Richard J Bold","doi":"10.1080/17434440.2023.2284790","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Sentinel lymph node biopsy for breast cancer is a method to localize and excise the first draining lymph node from an invasive cancer of the breast. The histopathologic evaluation of the sentinel lymph node is used for predicting recurrence and survival and thus, guiding oncologists for treatment-decision making to administer adjuvant therapies. The ability to identify the sentinel node depends on methods to map lymphatic drainage from the breast to the sentinel node and accurately discriminate that node from other non-sentinel lymph nodes of the axilla.</p><p><strong>Areas covered: </strong>This review covers the clinical demand for technologies to assist the surgeon in intraoperative lymphatic mapping to specifically identify the sentinel lymph node in patients with breast cancer. Performance characteristics are reviewed for superparamagnetic iron oxide tracers used in lymphatic mapping compared to other current available technologies for lymphatic mapping.</p><p><strong>Expert opinion: </strong>The Magtrace (superparamagnetic iron oxide tracer) Sentimag (handheld magnetic probe) system is an FDA-approved technology for intraoperative lymphatic mapping to facilitate sentinel lymph node biopsy in breast cancer with technologic performance characteristics that are equivalent to <sup>99</sup>Technetium-sulfur colloid. Barriers to broader utilization primarily center around the need for nonmetallic devices to be used for the conduct of surgery, which would interfere with the paramagnetic method for tracer localization.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2284790","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/4 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Sentinel lymph node biopsy for breast cancer is a method to localize and excise the first draining lymph node from an invasive cancer of the breast. The histopathologic evaluation of the sentinel lymph node is used for predicting recurrence and survival and thus, guiding oncologists for treatment-decision making to administer adjuvant therapies. The ability to identify the sentinel node depends on methods to map lymphatic drainage from the breast to the sentinel node and accurately discriminate that node from other non-sentinel lymph nodes of the axilla.
Areas covered: This review covers the clinical demand for technologies to assist the surgeon in intraoperative lymphatic mapping to specifically identify the sentinel lymph node in patients with breast cancer. Performance characteristics are reviewed for superparamagnetic iron oxide tracers used in lymphatic mapping compared to other current available technologies for lymphatic mapping.
Expert opinion: The Magtrace (superparamagnetic iron oxide tracer) Sentimag (handheld magnetic probe) system is an FDA-approved technology for intraoperative lymphatic mapping to facilitate sentinel lymph node biopsy in breast cancer with technologic performance characteristics that are equivalent to 99Technetium-sulfur colloid. Barriers to broader utilization primarily center around the need for nonmetallic devices to be used for the conduct of surgery, which would interfere with the paramagnetic method for tracer localization.