{"title":"Flow calibration system with the use of fully rotary directive valve","authors":"Paweł Kóscielniak, Małgorzata Herman, Joanna Janiszewska","doi":"10.1002/(SICI)1098-2728(1999)11:2<111::AID-LRA7>3.0.CO;2-%23","DOIUrl":null,"url":null,"abstract":"<p>The flow system with fully rotary valve (FRV) operated as a directive valve has been designed and applied for calibration purposes. The role of the FRV was to create the set of standard solutions of compositions desired by directing and merging the streams of a single initial standard solution inserted into a flow manifold. The idea is presented of how different numbers of standards with the analyte concentrations distributed variously along a calibration line are possible to be prepared. It has been experimentally revealed that the system developed allows one to perform the calibration procedure with low consumption of time, work, and reagents, providing accurate and precise analytical results. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 111–119, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 2","pages":"111-119"},"PeriodicalIF":0.0000,"publicationDate":"1999-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A2%3C111%3A%3AAID-LRA7%3E3.0.CO%3B2-%23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The flow system with fully rotary valve (FRV) operated as a directive valve has been designed and applied for calibration purposes. The role of the FRV was to create the set of standard solutions of compositions desired by directing and merging the streams of a single initial standard solution inserted into a flow manifold. The idea is presented of how different numbers of standards with the analyte concentrations distributed variously along a calibration line are possible to be prepared. It has been experimentally revealed that the system developed allows one to perform the calibration procedure with low consumption of time, work, and reagents, providing accurate and precise analytical results. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 111–119, 1999
流量校准系统采用全回转导向阀
设计并应用了全回转阀(FRV)作为指示阀操作的流量系统,用于校准。FRV的作用是通过引导和合并插入流歧管的单个初始标准溶液的流来创建所需的组合标准溶液集。提出了如何制备不同数量的标准品,分析物浓度沿校准线分布不同。实验表明,所开发的系统可以在低时间、低工作和低试剂消耗的情况下进行校准过程,提供准确和精确的分析结果。©1999 John Wiley &儿子,Inc。实验室机器人与自动化(英文版),1999
本文章由计算机程序翻译,如有差异,请以英文原文为准。