Arterial bolus curve after intravenous injection of ionic and nonionic contrast media.

E Gmelin, E Rinast, C Ollrogge
{"title":"Arterial bolus curve after intravenous injection of ionic and nonionic contrast media.","authors":"E Gmelin,&nbsp;E Rinast,&nbsp;C Ollrogge","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Studies of the intra-arterial bolus curve after intravenous contrast injection with dynamic computed tomography show that a higher bolus maximum can be obtained with a central injection than with a peripheral injection, other injection parameters remaining unchanged. In a singular venous injection ionic and nonionic contrast media show no different effects on the bolus curve. Due to the unfavorable effects of ionic contrast media with high osmolality, for the purposes of intravenous digital substraction angiography nonionic contrast media must be recommended. The subsequent injection of sodium chloride results in a higher bolus maximum.</p>","PeriodicalId":75861,"journal":{"name":"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband","volume":"128 ","pages":"67-9"},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Studies of the intra-arterial bolus curve after intravenous contrast injection with dynamic computed tomography show that a higher bolus maximum can be obtained with a central injection than with a peripheral injection, other injection parameters remaining unchanged. In a singular venous injection ionic and nonionic contrast media show no different effects on the bolus curve. Due to the unfavorable effects of ionic contrast media with high osmolality, for the purposes of intravenous digital substraction angiography nonionic contrast media must be recommended. The subsequent injection of sodium chloride results in a higher bolus maximum.

静脉注射离子和非离子造影剂后动脉灌注曲线。
动态计算机断层扫描对静脉造影剂注射后动脉内丸曲线的研究表明,在其他注射参数不变的情况下,中心注射比外周注射可获得更高的最大丸量。在单次静脉注射中,离子和非离子造影剂对剂量曲线没有不同的影响。由于高渗透压离子造影剂的不利影响,对于静脉数字减影血管造影术的目的,必须推荐非离子造影剂。随后注射氯化钠导致更高的最大剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信