« FORSAFE » forceps et capteurs souples bio-inspirés

P.-M. Schmitt, C. Ramon, C. Gehin, A. Dittmar
{"title":"« FORSAFE » forceps et capteurs souples bio-inspirés","authors":"P.-M. Schmitt,&nbsp;C. Ramon,&nbsp;C. Gehin,&nbsp;A. Dittmar","doi":"10.1016/j.rbmret.2007.01.002","DOIUrl":null,"url":null,"abstract":"<div><p>Living tissues are mainly constituted of soft matter. This so particular state, neither liquid, neither gas, nor solid led to the use, in simulation, of increasingly complicated mathematical models. These tissues are organised in multi-layers, present anisotropic properties and nonlinear behaviour. The evaluation of the interface pressure by traditional rigid sensors leads to errors of measurement. The device FORSAFE performs the measurement of the pressure on the fetal head. It is aimed to limit the risks due to a bad positioning and a too important tightening of the forceps on the head of the new-born, during the childbirth. It is based on an original method bio-inspired reproducing the sense of touch, by micro-palpations. Complications in forceps deliveries are rare but their consequences might be dramatics. This situation could be avoided if the obstetrician knows the information concerning symmetry of the obstetrical forceps position on the fetal head and the related interface pressure. Indeed, forceps delivery is an emergency gesture which is normally not expected. The aims of the FORSAFE device are: first, to prevent instrumented delivery accidents, secondly, to provide a safe training of forceps technique. This paper presents the original method of the interface pressure measurement, the results obtained on a physical model of interface pressure as well as the corrections performed on the probe placed on the forceps.</p></div>","PeriodicalId":100733,"journal":{"name":"ITBM-RBM","volume":"27 5","pages":"Pages 212-216"},"PeriodicalIF":0.0000,"publicationDate":"2006-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.rbmret.2007.01.002","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ITBM-RBM","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1297956207000034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Living tissues are mainly constituted of soft matter. This so particular state, neither liquid, neither gas, nor solid led to the use, in simulation, of increasingly complicated mathematical models. These tissues are organised in multi-layers, present anisotropic properties and nonlinear behaviour. The evaluation of the interface pressure by traditional rigid sensors leads to errors of measurement. The device FORSAFE performs the measurement of the pressure on the fetal head. It is aimed to limit the risks due to a bad positioning and a too important tightening of the forceps on the head of the new-born, during the childbirth. It is based on an original method bio-inspired reproducing the sense of touch, by micro-palpations. Complications in forceps deliveries are rare but their consequences might be dramatics. This situation could be avoided if the obstetrician knows the information concerning symmetry of the obstetrical forceps position on the fetal head and the related interface pressure. Indeed, forceps delivery is an emergency gesture which is normally not expected. The aims of the FORSAFE device are: first, to prevent instrumented delivery accidents, secondly, to provide a safe training of forceps technique. This paper presents the original method of the interface pressure measurement, the results obtained on a physical model of interface pressure as well as the corrections performed on the probe placed on the forceps.

“安全”生物灵感软钳和传感器
活体组织主要由软物质构成。这种既非液态,也非气态,也非固态的特殊状态导致了在模拟中使用越来越复杂的数学模型。这些组织呈多层结构,具有各向异性和非线性行为。传统的刚性传感器测量界面压力存在测量误差。该设备FORSAFE执行胎儿头部压力的测量。它的目的是限制风险,由于不良的定位和过于重要的收紧在新生儿的头部的产钳,在分娩过程中。它是基于一种原始的方法,仿生再现触觉,通过微触诊。在产钳分娩并发症是罕见的,但其后果可能是戏剧性的。如果产科医生了解产钳在胎儿头部位置的对称性和相关的界面压力,这种情况是可以避免的。事实上,产钳分娩是一种通常不被期望的紧急姿态。FORSAFE设备的目的是:首先,防止器械分娩事故,其次,提供钳技术的安全培训。本文介绍了界面压力测量的原始方法,在界面压力物理模型上得到的结果,以及对放置在钳上的探针进行的修正。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信