[Bond strength of an etched Co-Cr alloy].

Taehan Ch'ikkwa Uisa Hyophoe chi Pub Date : 1989-05-01
H Y Chung, S H Lee, J H Yang
{"title":"[Bond strength of an etched Co-Cr alloy].","authors":"H Y Chung,&nbsp;S H Lee,&nbsp;J H Yang","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to test the bond strength of a Co-Cr alloy. 40 cylindrical specimens (4 mm in diameter) were made of non-surgical Vitallium, and tensile bond strength was measured after etching and bonding. Etching was done with Oxy-Etch, and etching conditions were as follows: Composition of etching solution: Cone. nitric acid; 1 part glacial acetic acid; 1 part distilled water; 2 parts Current: 300 ma/cm2 Etching time: 3 min. The results were as follows: 1. Tensile bond strength was 435 +/- 116 kg/cm2 2. The result of this study shows that this etching method could be clinically applicable.</p>","PeriodicalId":76952,"journal":{"name":"Taehan Ch'ikkwa Uisa Hyophoe chi","volume":"27 5","pages":"467-71"},"PeriodicalIF":0.0000,"publicationDate":"1989-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Taehan Ch'ikkwa Uisa Hyophoe chi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study was to test the bond strength of a Co-Cr alloy. 40 cylindrical specimens (4 mm in diameter) were made of non-surgical Vitallium, and tensile bond strength was measured after etching and bonding. Etching was done with Oxy-Etch, and etching conditions were as follows: Composition of etching solution: Cone. nitric acid; 1 part glacial acetic acid; 1 part distilled water; 2 parts Current: 300 ma/cm2 Etching time: 3 min. The results were as follows: 1. Tensile bond strength was 435 +/- 116 kg/cm2 2. The result of this study shows that this etching method could be clinically applicable.

[蚀刻Co-Cr合金的结合强度]。
本研究的目的是测试Co-Cr合金的结合强度。非手术用vitalum制作40个直径为4mm的圆柱形试样,刻蚀粘结后测量拉伸粘结强度。采用氧基蚀刻机进行蚀刻,蚀刻条件如下:蚀刻液组成:锥形。硝酸;1份冰醋酸;1份蒸馏水;2部分电流:300 ma/cm2刻蚀时间:3 min。拉伸粘结强度为435 +/- 116 kg/cm2 2。本研究结果表明,该方法具有临床应用价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信