The Effect of Intracochlear and Intratympanic Dexamethasone on Cochlear Implant Impedance

Fazıl Necdet Ardıç, Gökçe Aydemir, Funda Tümkaya, Ece Altınöz, Hande Şenol
{"title":"The Effect of Intracochlear and Intratympanic Dexamethasone on Cochlear Implant Impedance","authors":"Fazıl Necdet Ardıç, Gökçe Aydemir, Funda Tümkaya, Ece Altınöz, Hande Şenol","doi":"10.4274/tao.2023.2023-6-4","DOIUrl":null,"url":null,"abstract":"Objective: This study investigated the impact of different local corticosteroid applications on impedance measurements in patients with cochlear implants. Methods: The study was designed as a controlled, randomized, and prospective study in which 34 consecutive patients who had undergone cochlear implant surgery were divided into three groups. The first group received intracochlear dexamethasone, in the second group the middle ear cavity was filled with dexamethasone, and the third group did not receive dexamethasone. Intraoperative, postoperative 1st week, 1st month, 3rd month, 6th-month neural response telemetry, and impedances were measured. The measurements were compared by electrode groups representing the different regions of cochlea like basal (1–7), middle (8–13), and apical (14–22) regions. Results: The intergroup analysis showed no statistically significant differences in impedance measurements of the basal, middle, and apical regions (p>0.05). However, the impedances were lower in the two dexamethasone groups, especially in the basal and middle parts. Sixth month impedances were also lower in the dexamethasone groups. There was apparent stability in the impedance of the basal region with the intracochlear application during the first week. Conclusion: Local dexamethasone applications had a potentially positive impact on the impedance of the basal and middle regions. Patients had lower impedances than the control group during follow-up and at the endpoint. The increase in the apical region may indicate that dexamethasone was not reaching the apical zone in local applications.","PeriodicalId":486177,"journal":{"name":"Türk otolarengoloji arşivi","volume":"16 7","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Türk otolarengoloji arşivi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/tao.2023.2023-6-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study investigated the impact of different local corticosteroid applications on impedance measurements in patients with cochlear implants. Methods: The study was designed as a controlled, randomized, and prospective study in which 34 consecutive patients who had undergone cochlear implant surgery were divided into three groups. The first group received intracochlear dexamethasone, in the second group the middle ear cavity was filled with dexamethasone, and the third group did not receive dexamethasone. Intraoperative, postoperative 1st week, 1st month, 3rd month, 6th-month neural response telemetry, and impedances were measured. The measurements were compared by electrode groups representing the different regions of cochlea like basal (1–7), middle (8–13), and apical (14–22) regions. Results: The intergroup analysis showed no statistically significant differences in impedance measurements of the basal, middle, and apical regions (p>0.05). However, the impedances were lower in the two dexamethasone groups, especially in the basal and middle parts. Sixth month impedances were also lower in the dexamethasone groups. There was apparent stability in the impedance of the basal region with the intracochlear application during the first week. Conclusion: Local dexamethasone applications had a potentially positive impact on the impedance of the basal and middle regions. Patients had lower impedances than the control group during follow-up and at the endpoint. The increase in the apical region may indicate that dexamethasone was not reaching the apical zone in local applications.
耳蜗内和鼓室内地塞米松对人工耳蜗阻抗的影响
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信