{"title":"Inter- and Intra-rater Reliability of Measurement of Range of Motion of the Shoulder Joint Using an iPhone","authors":"Yuta NISHIYAMA, Yuika KUNIEDA, Ryota MYOTSUZONO, Yasutaka TATSUMI","doi":"10.1589/rika.38.361","DOIUrl":null,"url":null,"abstract":"[Purpose] The purpose of this study was to clarify the intra- and inter-rater reliability of an iPhone measurement application. [Participants and Methods] The subjects were 10 male university students, 20 arms, and the intraclass correlation coefficient (ICC) was calculated for those who did and did not use an iPhone for measurement. The range of motion of external and internal rotation of the shoulder joint was measured in the supine position with the shoulder joint in 90 degrees of external rotation, the elbow joint in 90 degrees of external rotation, and the forearm in the middle position. [Results] The intra-rater reliability of shoulder joint external rotation and internal rotation range of motion measurement was ICC (1,1) and (1,2) = 0.9 or higher. The inter-rater reliability of shoulder joint external rotation and internal rotation range of motion measurement was ICC (2,1) and (2,2) = 0.8 or higher. [Conclusion] The iPhone-based shoulder rotation range-of-motion measurement was found to be highly reliable.","PeriodicalId":55872,"journal":{"name":"Rigakuryoho Kagaku","volume":"693 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rigakuryoho Kagaku","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1589/rika.38.361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

[Purpose] The purpose of this study was to clarify the intra- and inter-rater reliability of an iPhone measurement application. [Participants and Methods] The subjects were 10 male university students, 20 arms, and the intraclass correlation coefficient (ICC) was calculated for those who did and did not use an iPhone for measurement. The range of motion of external and internal rotation of the shoulder joint was measured in the supine position with the shoulder joint in 90 degrees of external rotation, the elbow joint in 90 degrees of external rotation, and the forearm in the middle position. [Results] The intra-rater reliability of shoulder joint external rotation and internal rotation range of motion measurement was ICC (1,1) and (1,2) = 0.9 or higher. The inter-rater reliability of shoulder joint external rotation and internal rotation range of motion measurement was ICC (2,1) and (2,2) = 0.8 or higher. [Conclusion] The iPhone-based shoulder rotation range-of-motion measurement was found to be highly reliable.
使用iPhone测量肩关节活动范围的内部和内部可靠性
[目的]本研究的目的是澄清iPhone测量应用程序的内部和内部可靠性。【参与者与方法】研究对象为10名男性大学生,20支手臂,计算使用iPhone和未使用iPhone的班级内相关系数(ICC)。在仰卧位,肩关节外旋90度,肘关节外旋90度,前臂居中位,测量肩关节外旋和内旋的活动范围。[结果]肩关节外旋和内旋运动测量范围的评分内信度ICC(1,1)和(1,2)= 0.9及以上。肩关节外旋和内旋运动测量范围的评分间信度为ICC(2,1)和(2,2)= 0.8或更高。[结论]基于iphone的肩部旋转运动范围测量是高度可靠的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Rigakuryoho Kagaku
Rigakuryoho Kagaku Health Professions-Physical Therapy, Sports Therapy and Rehabilitation
CiteScore
0.10
自引率
0.00%
发文量
58
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信