Calculation Array Solar Panel Capacity of 50 kWP Pamulang University South Tangerang

Aripin Triyanto, Ojak Abdul Rozak, Aditya Aditya
{"title":"Calculation Array Solar Panel Capacity of 50 kWP Pamulang University South Tangerang","authors":"Aripin Triyanto, Ojak Abdul Rozak, Aditya Aditya","doi":"10.33387/protk.v10i3.5795","DOIUrl":null,"url":null,"abstract":"Pamulang University is located in the South Tangerang area consisting of three buildings and 6 faculties and 5 of them are engineering faculties. Currently implementing Solar Panels is being carried out by the Faculty of Electrical Engineering, namely the application of new renewable energy sources. Installation of a solar power plant with a capacity of 50 KWP On-Grid is used as a provider of electricity for building lighting. The purpose of calculating the number of arrays is to determine the area and output power of the arranged solar panels. The problems faced before installation are the number of solar panels that will be arranged in the rooftop area, the amount of solar radiation and the output power. The use of research methods through the stages of calculation, monitoring, and standardization references was carried out for two weeks. The measuring instrument used in the research is the Seaward Solar Survey 200R, while the Global Solar Atlas (GSA) is used as a reference for insolation values in December 2022. The calculation results for the area of the array are 325.62 m², the PLTS electrical energy (EL) calculation is 393, 12 kWh, GSA of 6.14 kWh /m²/day, temperature correction factor (TCF) of 0.96, number of PLTS 102 solar panels with 6 PV strings, highest inverter output of 272.8 kWh and lowest value of 133.2 kWh","PeriodicalId":482060,"journal":{"name":"Protek: Jurnal Ilmiah Teknik Elektro","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Protek: Jurnal Ilmiah Teknik Elektro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33387/protk.v10i3.5795","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Pamulang University is located in the South Tangerang area consisting of three buildings and 6 faculties and 5 of them are engineering faculties. Currently implementing Solar Panels is being carried out by the Faculty of Electrical Engineering, namely the application of new renewable energy sources. Installation of a solar power plant with a capacity of 50 KWP On-Grid is used as a provider of electricity for building lighting. The purpose of calculating the number of arrays is to determine the area and output power of the arranged solar panels. The problems faced before installation are the number of solar panels that will be arranged in the rooftop area, the amount of solar radiation and the output power. The use of research methods through the stages of calculation, monitoring, and standardization references was carried out for two weeks. The measuring instrument used in the research is the Seaward Solar Survey 200R, while the Global Solar Atlas (GSA) is used as a reference for insolation values in December 2022. The calculation results for the area of the array are 325.62 m², the PLTS electrical energy (EL) calculation is 393, 12 kWh, GSA of 6.14 kWh /m²/day, temperature correction factor (TCF) of 0.96, number of PLTS 102 solar panels with 6 PV strings, highest inverter output of 272.8 kWh and lowest value of 133.2 kWh
计算阵列太阳能电池板容量50kwp帕慕朗大学南坦格朗
帕慕朗大学位于南坦格朗地区,由3栋楼和6个学院组成,其中5个是工程学院。目前,电气工程学院正在实施太阳能电池板,即应用新的可再生能源。安装装机容量为50kwp的太阳能发电厂并网发电,为建筑照明提供电力。计算阵列数量的目的是确定排列的太阳能电池板的面积和输出功率。安装前面临的问题是将在屋顶区域布置的太阳能电池板的数量,太阳辐射量和输出功率。采用的研究方法通过计算、监测、标准化参考等阶段进行了为期两周的研究。研究中使用的测量仪器是向海太阳测量200R,而全球太阳地图集(GSA)是2022年12月日晒值的参考。阵列面积计算结果为325.62 m²,PLTS电能(EL)计算结果为393,12 kWh, GSA为6.14 kWh /m²/day,温度校正系数(TCF)为0.96,PLTS 102太阳能电池板数量为6个PV串,逆变器输出最高272.8 kWh,最低133.2 kWh
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书