Analysis of probable consequences of cement composite frost destruction

B. I. Pinus
{"title":"Analysis of probable consequences of cement composite frost destruction","authors":"B. I. Pinus","doi":"10.21285/2227-2917-2023-3-538-544","DOIUrl":null,"url":null,"abstract":"The article presents an analysis of variations in the internal resistance of standard and fiberreinforced cement composites under non-stationary low-temperature and humidity effects. Various aspects of the response kinetics of prismatic samples in the monotonous compression mode are considered. The sample set included control samples and those subjected to cyclic freezing and thawing according to their standard frost resistance. Test samples (100 × 100 × 400 mm) were made of conventional (B series) and fiber-reinforced (FB, polypropylene fibers df = 0.8 mm, lf = 40 mm, µf = 1.5 vol%) concrete with a component ratio of cement: sand: crushed stone: water = 1:1.42:3.57:0.55. The accepted base of T-W cycles corresponded to the standard concrete grade in terms of frost resistance, established in control tests (F200). Static tests of composites were preceded by low-temperature exposures according to an accelerated method for assessing frost resistance with a temperature decrease down to minus 35℃ and thawing in a 5% NaCl solution. Samples were automatically loaded (Instron 5989 test complex) according to a special program with a constant deformation rate of 5·10-5 mm/s and continuous recording of deformations. Significant differences were observed in the strength kinetics, magnitude and structure of deformations, along with a high sensitivity and quantitative informativeness of the significant parameters of the strength kinetic concept for solid bodies. The expediency of a differentiated approach to the selection of calculation models and criteria for the temperature and humidity transformations of cement-matrix composites, which takes operational requirements into account, is substantiated.","PeriodicalId":32211,"journal":{"name":"Izvestia Vuzov Investicii Stroitel''stvo Nedvizimost''","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Izvestia Vuzov Investicii Stroitel''stvo Nedvizimost''","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21285/2227-2917-2023-3-538-544","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article presents an analysis of variations in the internal resistance of standard and fiberreinforced cement composites under non-stationary low-temperature and humidity effects. Various aspects of the response kinetics of prismatic samples in the monotonous compression mode are considered. The sample set included control samples and those subjected to cyclic freezing and thawing according to their standard frost resistance. Test samples (100 × 100 × 400 mm) were made of conventional (B series) and fiber-reinforced (FB, polypropylene fibers df = 0.8 mm, lf = 40 mm, µf = 1.5 vol%) concrete with a component ratio of cement: sand: crushed stone: water = 1:1.42:3.57:0.55. The accepted base of T-W cycles corresponded to the standard concrete grade in terms of frost resistance, established in control tests (F200). Static tests of composites were preceded by low-temperature exposures according to an accelerated method for assessing frost resistance with a temperature decrease down to minus 35℃ and thawing in a 5% NaCl solution. Samples were automatically loaded (Instron 5989 test complex) according to a special program with a constant deformation rate of 5·10-5 mm/s and continuous recording of deformations. Significant differences were observed in the strength kinetics, magnitude and structure of deformations, along with a high sensitivity and quantitative informativeness of the significant parameters of the strength kinetic concept for solid bodies. The expediency of a differentiated approach to the selection of calculation models and criteria for the temperature and humidity transformations of cement-matrix composites, which takes operational requirements into account, is substantiated.
水泥复合材料冻损可能后果分析
本文分析了非稳态低温、湿气作用下标准水泥和纤维增强水泥复合材料内阻的变化规律。考虑了柱状试样在单调压缩模式下的响应动力学的各个方面。样品集包括对照样品和根据其标准抗冻性进行循环冻融的样品。试验样品(100 × 100 × 400 mm)由常规(B系列)和纤维增强(FB,聚丙烯纤维df = 0.8 mm, lf = 40 mm,µf = 1.5 vol%)混凝土制成,水泥:砂:碎石:水= 1:1.42:3.57:0.55。T-W循环的可接受基础与对照试验(F200)中建立的标准混凝土抗冻等级相对应。复合材料的静态测试之前,根据低温加速法评估抗冻性,温度降低到零下35℃,在5%的NaCl溶液中融化。样品按特殊程序自动加载(Instron 5989测试复核),恒定的变形速率为5·10-5 mm/s,并连续记录变形。在强度动力学、变形的大小和结构上观察到显著的差异,以及固体强度动力学概念的重要参数的高灵敏度和定量信息。对水泥基复合材料的温度和湿度变化的计算模型和标准的选择,考虑到操作要求的差异化方法的便利性,是证实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书