Investigation of Leachate Plume and Groundwater Pollution using Geophysical and Physio-chemical Methods in an Open Dumpsite at Idugosa, Federal Capital Territory (FCT), Abuja, Nigeria

Rita C Agu, Abu Mallam
{"title":"Investigation of Leachate Plume and Groundwater Pollution using Geophysical and Physio-chemical Methods in an Open Dumpsite at Idugosa, Federal Capital Territory (FCT), Abuja, Nigeria","authors":"Rita C Agu, Abu Mallam","doi":"10.47514/phyaccess.2023.3.2.004","DOIUrl":null,"url":null,"abstract":"A geophysical study has been carried out using the electrical resistivity method, Very LowFrequency Electromagnetic (VLF-EM) and physiochemical analysis to investigate the effects of groundwater contamination in the vicinity of an open dumpsite at Idugosa. A Vertical Electrical sounding was carried out at 100 m away from the dumpsite and the results revealed an H-type curve with 3- layers, with a low resistivity value of 90.0 Ωm, thickness of 9.8 m and depth of 11.3 m at the weathered basement. The control VES revealed 5 –layers of HK-type curve. The resistivity of the weathered and fractured basement ranged from 241.8 Ωm to 2908.4 Ωm with a thickness range of 3.5 m to 13.6 m and a depth range of 5.6 m to 19.1 m. Results of the horizontal profiling using Wenner profiling revealed a low resistivity value of 1.6 Ωm to 3.8 Ωm at a depth of 15 m to 30 m, concentrated at stations 20 to 100. The bottom of the western part showed that the leachate plume had infiltrated and contaminated the groundwater in the zone. The VLF-EM with the three profiles revealed high current density values on the KarousHjelt filter plot at distances of 20 m to 38 m for profile 1, 25 m to 50 m and 75 m to 95 m for profile 2, revealing the presence of contaminants which is mainly from decayed organic matter from waste bodies and heavy metals from the dumpsite. Profile 3 which is further away from profile 1 revealed that the contamination is reduced as we move further away from the dumpsite at about 10 m to 20 m, 50 m to 60 m and 90 m respectively. The physio-chemical analysis results showed a pH range of 6.73 – 7.17 which is within the World Health Organization (WHO) standard (6.5 - 8.5). The Electrical Conductivity (EC) value of the Idugosa dumpsite was found to be 804.9 μS/cm, which is above the WHO standard for EC values, which should not exceed 400 μS/cm. This high value can be attributed to the infiltration of the leachate plume from the dumpsite. The EC for Idugosa control which is 188.0 μS/cm is within the WHO limit for groundwater, thus its safe for consumption.","PeriodicalId":474567,"journal":{"name":"Physics Access","volume":"2020 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics Access","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47514/phyaccess.2023.3.2.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A geophysical study has been carried out using the electrical resistivity method, Very LowFrequency Electromagnetic (VLF-EM) and physiochemical analysis to investigate the effects of groundwater contamination in the vicinity of an open dumpsite at Idugosa. A Vertical Electrical sounding was carried out at 100 m away from the dumpsite and the results revealed an H-type curve with 3- layers, with a low resistivity value of 90.0 Ωm, thickness of 9.8 m and depth of 11.3 m at the weathered basement. The control VES revealed 5 –layers of HK-type curve. The resistivity of the weathered and fractured basement ranged from 241.8 Ωm to 2908.4 Ωm with a thickness range of 3.5 m to 13.6 m and a depth range of 5.6 m to 19.1 m. Results of the horizontal profiling using Wenner profiling revealed a low resistivity value of 1.6 Ωm to 3.8 Ωm at a depth of 15 m to 30 m, concentrated at stations 20 to 100. The bottom of the western part showed that the leachate plume had infiltrated and contaminated the groundwater in the zone. The VLF-EM with the three profiles revealed high current density values on the KarousHjelt filter plot at distances of 20 m to 38 m for profile 1, 25 m to 50 m and 75 m to 95 m for profile 2, revealing the presence of contaminants which is mainly from decayed organic matter from waste bodies and heavy metals from the dumpsite. Profile 3 which is further away from profile 1 revealed that the contamination is reduced as we move further away from the dumpsite at about 10 m to 20 m, 50 m to 60 m and 90 m respectively. The physio-chemical analysis results showed a pH range of 6.73 – 7.17 which is within the World Health Organization (WHO) standard (6.5 - 8.5). The Electrical Conductivity (EC) value of the Idugosa dumpsite was found to be 804.9 μS/cm, which is above the WHO standard for EC values, which should not exceed 400 μS/cm. This high value can be attributed to the infiltration of the leachate plume from the dumpsite. The EC for Idugosa control which is 188.0 μS/cm is within the WHO limit for groundwater, thus its safe for consumption.
尼日利亚阿布贾联邦首都地区(FCT) Idugosa露天垃圾场渗滤液和地下水污染的地球物理和理化方法研究
利用电阻率法、甚低频电磁(VLF-EM)和物理化学分析进行了一项地球物理研究,以调查Idugosa露天垃圾场附近地下水污染的影响。在距堆场100 m处进行了垂直电测深,结果显示在风化基底处呈现3层h型曲线,低电阻率值为90.0 Ωm,厚度9.8 m,深度11.3 m。对照超声心动图显示5层hk型曲线。风化破碎基底的电阻率范围为241.8 Ωm ~ 2908.4 Ωm,厚度为3.5 m ~ 13.6 m,深度为5.6 m ~ 19.1 m。Wenner剖面水平剖面结果显示,15 ~ 30 m深度电阻率值为1.6 Ωm ~ 3.8 Ωm,集中在20 ~ 100站。西部底部显示渗滤液柱已经渗入并污染了区内地下水。三种剖面的VLF-EM在KarousHjelt滤波图上显示出高电流密度值,剖面1在距离20 m至38 m处,剖面1在距离25 m至50 m处,剖面2在距离75 m至95 m处,表明污染物的存在,这些污染物主要来自废物体的腐烂有机物和垃圾场的重金属。离剖面1较远的剖面3显示,随着我们离垃圾场越远,污染程度越低,分别为10米至20米,50米至60米和90米。理化分析结果表明,其pH值范围为6.73 ~ 7.17,符合世界卫生组织(WHO)标准(6.5 ~ 8.5)。结果表明,该垃圾场的电导率(EC)值为804.9 μS/cm,高于WHO规定的EC值不超过400 μS/cm的标准。这一高数值可归因于垃圾场渗滤液羽流的渗透。Idugosa控制的EC值为188.0 μS/cm,在WHO地下水标准内,可安全饮用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书