Changing the geometry of polymer spherical orbital implants

Dmitry V. Davydov, Nadezda A. Baranova
{"title":"Changing the geometry of polymer spherical orbital implants","authors":"Dmitry V. Davydov, Nadezda A. Baranova","doi":"10.17816/ov546107","DOIUrl":null,"url":null,"abstract":"BACKGROUND: Over the past decades, various polymer implants have been actively used in the rehabilitation of patients with anophthalmos to form a volumetric support stump and improve the results of cosmetic prosthetics.
 AIM: To assess clinical symptoms and features of the X-ray picture in patients with anophthalmos after implantation of polymeric spherical endoprostheses with a modified geometry.
 MATERIALS AND METHODS: The study is based on the analysis of 30 patients with anophthalmos after enucleations (23) and eviscerations (7) performed using various methods of procedure and insertion into tissues of an implant made of domestic polytetrafluoroethylene. All patients underwent a multispiral computed tomography (MSCT) of the eye sockets according to the same algorithm.
 RESULTS: On the basis of the performed studies, the fact of making a change in the geometry of the implanted spherical implants was revealed, while the parameters of the modified part of the spheres were different and ranged from 14 to 18 mm of final diameters with the initial diameters of the spheres ranging from 18 to 20 mm. A decrease in the volume of spheres with modified geometry from 0.114 to 0.651 cm3 was revealed with initial diameters ranging from 18 to 20 mm.
 CONCLUSIONS: Changes in the geometry of the orbital spheres do not improve the results of cosmetic prosthetics in patients, increase the percentage of implant exposure at different times after surgery, and increase the manifestations of anophthalmic syndrome.","PeriodicalId":496620,"journal":{"name":"Oftalʹmologičeskie vedomosti","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oftalʹmologičeskie vedomosti","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17816/ov546107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND: Over the past decades, various polymer implants have been actively used in the rehabilitation of patients with anophthalmos to form a volumetric support stump and improve the results of cosmetic prosthetics. AIM: To assess clinical symptoms and features of the X-ray picture in patients with anophthalmos after implantation of polymeric spherical endoprostheses with a modified geometry. MATERIALS AND METHODS: The study is based on the analysis of 30 patients with anophthalmos after enucleations (23) and eviscerations (7) performed using various methods of procedure and insertion into tissues of an implant made of domestic polytetrafluoroethylene. All patients underwent a multispiral computed tomography (MSCT) of the eye sockets according to the same algorithm. RESULTS: On the basis of the performed studies, the fact of making a change in the geometry of the implanted spherical implants was revealed, while the parameters of the modified part of the spheres were different and ranged from 14 to 18 mm of final diameters with the initial diameters of the spheres ranging from 18 to 20 mm. A decrease in the volume of spheres with modified geometry from 0.114 to 0.651 cm3 was revealed with initial diameters ranging from 18 to 20 mm. CONCLUSIONS: Changes in the geometry of the orbital spheres do not improve the results of cosmetic prosthetics in patients, increase the percentage of implant exposure at different times after surgery, and increase the manifestations of anophthalmic syndrome.
改变聚合物球形眼眶植入物的几何形状
背景:在过去的几十年里,各种聚合物植入物被积极地应用于眼球缺乏症患者的康复中,以形成体积支持残端,改善修复术的效果。 目的:探讨改良几何形状聚合物球形假体植入术后无眼的临床症状及x线征象特征。 材料和方法:本研究基于对30例眼球摘除术(23例)和剜出手术(7例)后眼球缺失的患者的分析,这些患者采用了不同的手术方法,并将国产聚四氟乙烯制成的植入物插入组织中。所有患者均按照相同的算法对眼窝进行了多螺旋计算机断层扫描(MSCT)。结果:在已有研究的基础上,揭示了植入球形假体的几何形状发生改变的事实,而修饰部分的球体参数不同,最终直径为14 ~ 18mm,初始直径为18 ~ 20mm。在初始直径为18 ~ 20 mm的情况下,经修正几何形状的球体体积从0.114 cm3减小到0.651 cm3。结论:眼眶球几何形状的改变并不能改善患者的修复效果,反而增加了术后不同时间种植体暴露的比例,并增加了无眼综合征的表现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信