Numerical investigation of clocking effect on unsteady fluid flow in vicinity of tongue for centrifugal pump with vaned diffuser

IF 1.2 4区 工程技术 Q3 ENGINEERING, MECHANICAL
Xiangyuan Zhu, Yiming Qiao, Changcheng Xie
{"title":"Numerical investigation of clocking effect on unsteady fluid flow in vicinity of tongue for centrifugal pump with vaned diffuser","authors":"Xiangyuan Zhu, Yiming Qiao, Changcheng Xie","doi":"10.1177/09576509231204026","DOIUrl":null,"url":null,"abstract":"In order to investigate the clocking effect on unsteady flow distortion in the vicinity of the tongue and hydraulic loss in the volute, experiments and numerical simulations were conducted with four different relative angular positions between the vane and tongue. Numerical results were validated against experimental data, which included measurements of pressure pulsation at the tongue and downstream of the tongue. The radial and circumferential velocities near the tongue at the diffuser-volute clearance were depicted by expanding the rotating surface, and comparisons were made under different diffuser positions to reveal the flow distortion affected by the clocking effect. Shear stress rates and total pressure distributions at the volute exit pipe were also depicted to study the flow loss in the volute affected by the flow pattern from the tongue. The findings show that the pressure fluctuation at the tongue and downstream of the tongue is significantly affected by the diffuser mounting position. The amplitude and intensity of pressure pulsation under θ d1 are clearly smaller than those at other diffuser positions. As the vane trailing edge approaches the tongue, the pressure gradient becomes very large, leading to the formation of a vortex at the tongue that promotes crowding effects and reverse flow occurring in the exit pipe. This, in turn, leads to deflection of the main flow in the volute, high velocity gradients, and subsequently large shear stress rates and hydraulic losses. When the diffuser is installed at θ d4 , the flow distortion and flow loss are improved.","PeriodicalId":20705,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2023-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/09576509231204026","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In order to investigate the clocking effect on unsteady flow distortion in the vicinity of the tongue and hydraulic loss in the volute, experiments and numerical simulations were conducted with four different relative angular positions between the vane and tongue. Numerical results were validated against experimental data, which included measurements of pressure pulsation at the tongue and downstream of the tongue. The radial and circumferential velocities near the tongue at the diffuser-volute clearance were depicted by expanding the rotating surface, and comparisons were made under different diffuser positions to reveal the flow distortion affected by the clocking effect. Shear stress rates and total pressure distributions at the volute exit pipe were also depicted to study the flow loss in the volute affected by the flow pattern from the tongue. The findings show that the pressure fluctuation at the tongue and downstream of the tongue is significantly affected by the diffuser mounting position. The amplitude and intensity of pressure pulsation under θ d1 are clearly smaller than those at other diffuser positions. As the vane trailing edge approaches the tongue, the pressure gradient becomes very large, leading to the formation of a vortex at the tongue that promotes crowding effects and reverse flow occurring in the exit pipe. This, in turn, leads to deflection of the main flow in the volute, high velocity gradients, and subsequently large shear stress rates and hydraulic losses. When the diffuser is installed at θ d4 , the flow distortion and flow loss are improved.
带叶片扩散器离心泵舌部附近非定常流体流动的时钟效应数值研究
为了研究时钟对舌部附近非定常流动畸变和蜗壳内水力损失的影响,在叶片与舌部之间的4种不同相对角度位置进行了实验和数值模拟。数值结果与实验数据进行了验证,包括舌部和舌部下游的压力脉动测量。通过扩展旋转表面,描述了扩压蜗壳间隙处舌部附近的径向和周向速度,并对不同扩压位置下的流动畸变进行了比较,揭示了时钟效应对流动畸变的影响。此外,还对蜗壳出口管道处的剪切应力率和总压分布进行了描述,以研究蜗壳内的流动损失受舌部流型的影响。结果表明,扩压器安装位置对舌舌处和舌舌下游的压力波动有显著影响。θ d1下压力脉动的幅值和强度明显小于扩散器其他位置。当叶片尾缘靠近舌部时,压力梯度变得非常大,导致舌部形成涡流,促进了拥挤效应,并在出口管道中发生逆流。这反过来又导致了蜗壳内主流的偏转、高速度梯度以及随后的大剪切应力率和水力损失。当扩压器安装在θ d4时,流动畸变和流动损失得到改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
5.90%
发文量
114
审稿时长
5.4 months
期刊介绍: The Journal of Power and Energy, Part A of the Proceedings of the Institution of Mechanical Engineers, is dedicated to publishing peer-reviewed papers of high scientific quality on all aspects of the technology of energy conversion systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信