Lysine-mediated tissue osmication in combination with a tannin-osmium conductive staining method for non-coated scanning electron microscopy of biological specimens.
T Murakami, Z L Song, H Hinenoya, A Ohtsuka, T Taguchi, J J Liu, T Sano
{"title":"Lysine-mediated tissue osmication in combination with a tannin-osmium conductive staining method for non-coated scanning electron microscopy of biological specimens.","authors":"T Murakami, Z L Song, H Hinenoya, A Ohtsuka, T Taguchi, J J Liu, T Sano","doi":"10.1679/aohc.50.485","DOIUrl":null,"url":null,"abstract":"<p><p>Glutaraldehyde fixed rat kidney blocks showed no charging effect when treated with lysine and osmic acid and viewed in a scanning electron microscope using an acceleration voltage of 5-30 kV and a specimen current of 1 X 10(-10) A. The podocyte processes and endothelial micropores of the glomerulus were visible without metal coating. Glutaraldehyde fixed, tannin-osmium impregnated and lysine-osmium treated specimens also showed no charging effect in the scanning electron microscope, yielding instead much clearer scanning images which were comparable to those obtained from gold-coated specimens or from tannin-osmium-thiocarbohydrazide-osmium impregnated specimens (Murakami and Jones, 1980).</p>","PeriodicalId":8387,"journal":{"name":"Archivum histologicum Japonicum = Nihon soshikigaku kiroku","volume":"50 5","pages":"485-93"},"PeriodicalIF":0.0000,"publicationDate":"1987-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1679/aohc.50.485","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivum histologicum Japonicum = Nihon soshikigaku kiroku","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1679/aohc.50.485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
Glutaraldehyde fixed rat kidney blocks showed no charging effect when treated with lysine and osmic acid and viewed in a scanning electron microscope using an acceleration voltage of 5-30 kV and a specimen current of 1 X 10(-10) A. The podocyte processes and endothelial micropores of the glomerulus were visible without metal coating. Glutaraldehyde fixed, tannin-osmium impregnated and lysine-osmium treated specimens also showed no charging effect in the scanning electron microscope, yielding instead much clearer scanning images which were comparable to those obtained from gold-coated specimens or from tannin-osmium-thiocarbohydrazide-osmium impregnated specimens (Murakami and Jones, 1980).