{"title":"A Novel, Rapid Response Renewable Biopolymer Neutron and Gamma Radiation Solid-State Detector for Dosimetry and Nuclear Reactor Flux-Power Mapping","authors":"Wen Jiang, True Miller, Troy Barlow, Nathan Boyle, Rusi P. Taleyarkhan","doi":"10.3390/instruments7030026","DOIUrl":null,"url":null,"abstract":"A novel solid-state neutron and gamma radiation monitor-dosimeter based on biopolymer polylactic acid (PLA) is presented. The resulting detector (PLAD) technology takes advantage of property changes of the renewable PLA resin when subject to ionizing nuclear radiation. A simple yet rapid and accurate (±10%) low-cost (<$0.01/detector) mass loss upon dissolution (MLD) technique was successfully developed; MLD is based on a simple mass balance for discerning neutron and/or gamma doses using small (40 mg, ~4 mm diameter) ultra-low-cost (<$0.01) resin beads via dissolution in acetone. The GammaCellTM Co-60 irradiator, and the PUR-1 12 kW fission nuclear research reactor were utilized, respectively. Irradiation absorbed doses ranged from 1 to 100 kGy. Acetone bath temperature was varied from ~40 °C to ~54 °C. Results revealed a strong dependence of MLD on acetone bath temperature between neutron and gamma photon dose components; this allowed for the unique ability of PLAD to potentially perform as both a neutron-cum-gamma or as a gamma or neutron radiation dosimeter and intensity level detector. A linear trend is found for combined neutron and gamma radiation doses from 0 to 40 kGy when dissolution is conducted above 50 °C. The important potential ability to distinguish neutron from gamma radiation fields was scoped and found to be feasible by determining MLD at 45 °C. The potential was studied for simultaneous use as an in-core neutron and gamma monitor of an operating 3 GWt light-water reactor (LWR). Scoping tests were conducted with the pre-irradiated (@ 20 °C) PLAD resin beads followed by heating to in-core LWR coolant (300 °C) conditions for ~30 s corresponding to the time to reach ~40 kGy total doses in a typical 3 GWt LWR. MLD results were unaffected, indicating the exciting and unique potential for in situ (low-cost, accurate and rapid) simultaneous mapping of neutron and gamma radiation fluxes, related dosimetry, and fission power level monitoring.","PeriodicalId":13582,"journal":{"name":"Instruments","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/instruments7030026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 0
Abstract
A novel solid-state neutron and gamma radiation monitor-dosimeter based on biopolymer polylactic acid (PLA) is presented. The resulting detector (PLAD) technology takes advantage of property changes of the renewable PLA resin when subject to ionizing nuclear radiation. A simple yet rapid and accurate (±10%) low-cost (<$0.01/detector) mass loss upon dissolution (MLD) technique was successfully developed; MLD is based on a simple mass balance for discerning neutron and/or gamma doses using small (40 mg, ~4 mm diameter) ultra-low-cost (<$0.01) resin beads via dissolution in acetone. The GammaCellTM Co-60 irradiator, and the PUR-1 12 kW fission nuclear research reactor were utilized, respectively. Irradiation absorbed doses ranged from 1 to 100 kGy. Acetone bath temperature was varied from ~40 °C to ~54 °C. Results revealed a strong dependence of MLD on acetone bath temperature between neutron and gamma photon dose components; this allowed for the unique ability of PLAD to potentially perform as both a neutron-cum-gamma or as a gamma or neutron radiation dosimeter and intensity level detector. A linear trend is found for combined neutron and gamma radiation doses from 0 to 40 kGy when dissolution is conducted above 50 °C. The important potential ability to distinguish neutron from gamma radiation fields was scoped and found to be feasible by determining MLD at 45 °C. The potential was studied for simultaneous use as an in-core neutron and gamma monitor of an operating 3 GWt light-water reactor (LWR). Scoping tests were conducted with the pre-irradiated (@ 20 °C) PLAD resin beads followed by heating to in-core LWR coolant (300 °C) conditions for ~30 s corresponding to the time to reach ~40 kGy total doses in a typical 3 GWt LWR. MLD results were unaffected, indicating the exciting and unique potential for in situ (low-cost, accurate and rapid) simultaneous mapping of neutron and gamma radiation fluxes, related dosimetry, and fission power level monitoring.