Effect of Suction Slot Location and Width on the Performance of Centrifugal Fan

Samer Beskales, Ibrahim Shahin, Samir Ayad, Osama Abdellatif, Tarek Mekhail
{"title":"Effect of Suction Slot Location and Width on the Performance of Centrifugal Fan","authors":"Samer Beskales, Ibrahim Shahin, Samir Ayad, Osama Abdellatif, Tarek Mekhail","doi":"10.21608/erjsh.2023.195852.1149","DOIUrl":null,"url":null,"abstract":": Blade slots are known to reduce the noise and improve flow behavior and steadiness in centrifugal fans. The present work considers an unsteady Computational Fluid Dynamic (CFD) study to investigate the effectiveness of slot location and width on the performance and flow field inside the centrifugal fan blade passages. The computer program, Fluent 19, is used and the 3D fan model is validated by comparing its results with those of earlier researchers. The aim of the present study is to find the best slot location and appropriate slot width at that location. The flow pattern is then analyzed and simulated with no slot and with a slot at six different radial locations; namely S1, S2, S3, S4, S5, and S6 with fixed slot width W of 2.5 mm. The computationally generated characteristics of unsteady flow demonstrated that although cut slots at all locations on the fan blade from the hub to the shroud has a negative influence on the centrifugal fan efficiency as well as the static pressure rise compared with the fan without slot, the slots added at S3 i.e. near the midpoint of the blade span gives the highest fan efficiency and largest increase in static pressure. Slots at S3 suppress secondary flow at the blade passages and push it to the blade tip. Additionally, streamlines and velocity distributions in impeller passages and over the blade surfaces (pressure and suction sides) validated the slots' benefits. Computations width different slot width; namely 1.5 mm, 3.5 mm, and 5 mm are carried out to find the best slot location and width at the best slot location S3. At the optimal efficiency point, the calculated performance of the employed fan with slot location S3 and 2.5 mm width, showed a 2.7 % increase of efficiency and 1.5% increase in static pressure rise as compared to fans with slot at S1 with same width of 2.5 mm. However, it showed a positive impact on the boundary layer buildup and flow separation over the blade suction side for the impeller studied .","PeriodicalId":159365,"journal":{"name":"Engineering Research Journal (Shoubra)","volume":"210 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Research Journal (Shoubra)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/erjsh.2023.195852.1149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: Blade slots are known to reduce the noise and improve flow behavior and steadiness in centrifugal fans. The present work considers an unsteady Computational Fluid Dynamic (CFD) study to investigate the effectiveness of slot location and width on the performance and flow field inside the centrifugal fan blade passages. The computer program, Fluent 19, is used and the 3D fan model is validated by comparing its results with those of earlier researchers. The aim of the present study is to find the best slot location and appropriate slot width at that location. The flow pattern is then analyzed and simulated with no slot and with a slot at six different radial locations; namely S1, S2, S3, S4, S5, and S6 with fixed slot width W of 2.5 mm. The computationally generated characteristics of unsteady flow demonstrated that although cut slots at all locations on the fan blade from the hub to the shroud has a negative influence on the centrifugal fan efficiency as well as the static pressure rise compared with the fan without slot, the slots added at S3 i.e. near the midpoint of the blade span gives the highest fan efficiency and largest increase in static pressure. Slots at S3 suppress secondary flow at the blade passages and push it to the blade tip. Additionally, streamlines and velocity distributions in impeller passages and over the blade surfaces (pressure and suction sides) validated the slots' benefits. Computations width different slot width; namely 1.5 mm, 3.5 mm, and 5 mm are carried out to find the best slot location and width at the best slot location S3. At the optimal efficiency point, the calculated performance of the employed fan with slot location S3 and 2.5 mm width, showed a 2.7 % increase of efficiency and 1.5% increase in static pressure rise as compared to fans with slot at S1 with same width of 2.5 mm. However, it showed a positive impact on the boundary layer buildup and flow separation over the blade suction side for the impeller studied .
吸槽位置和宽度对离心风机性能的影响
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信