Canal transportation and centering ability of HyFlex CM and TruNatomy rotary file systems in moderately curved root canals using CBCT: An in vitro study

Q3 Dentistry
Pooja D. Atigre, Leena Hiren Jobanputra, Aditya R. Sharma, Savan K. Kashiyani, Jaiprathiksha Venkatasubramaniam Iyer, Pushpa Kumari
{"title":"Canal transportation and centering ability of HyFlex CM and TruNatomy rotary file systems in moderately curved root canals using CBCT: An in vitro study","authors":"Pooja D. Atigre, Leena Hiren Jobanputra, Aditya R. Sharma, Savan K. Kashiyani, Jaiprathiksha Venkatasubramaniam Iyer, Pushpa Kumari","doi":"10.4103/endo.endo_182_22","DOIUrl":null,"url":null,"abstract":"ABSTRACT Aim: The objective of this study was to evaluate and compare canal transportation (CT) and centering ability (CA) in the curved canals prepared using HyFlex CM (HCM) and TruNatomy (TN) rotary file systems with the help of cone-beam computed tomography (CBCT). Materials and Methods: Forty extracted single-rooted mandibular premolars with 10°–30° of curvature were selected and divided into two groups. In Group 1, the canals were prepared with HCM files (Coltene Whaledent) and in Group 2 the canals were prepared with TN Prime rotary files (Dentsply Sirona). Pre- and postinstrumentation scans were performed at the same position using CBCT to evaluate CT and CA at three levels 3 mm, 6 mm, and 9 mm from the apex and were compared using CBCT software (On Demand 3D software). Statistical Analysis Used: The two groups were statistically analyzed with Mann–Whitney U -test. Results: There was no significant difference among the tested groups regarding the canal centering ratio ( P > 0.05). At 6- and 9-mm levels, there was no significant difference in CT among the two groups ( P > 0.05). However, at 3 mm from apex, there was a statistically significant difference ( P = 0.006) with TN files exhibiting lesser CT. Conclusion: Both the file systems respected the canal anatomy, although in the apical third, TN files exhibited better results. Hence, this file system can be considered for instrumentation of canals with moderate apical curvatures. In regard to CA, no significant differences were found among the file systems.","PeriodicalId":11607,"journal":{"name":"Endodontology","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/endo.endo_182_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Aim: The objective of this study was to evaluate and compare canal transportation (CT) and centering ability (CA) in the curved canals prepared using HyFlex CM (HCM) and TruNatomy (TN) rotary file systems with the help of cone-beam computed tomography (CBCT). Materials and Methods: Forty extracted single-rooted mandibular premolars with 10°–30° of curvature were selected and divided into two groups. In Group 1, the canals were prepared with HCM files (Coltene Whaledent) and in Group 2 the canals were prepared with TN Prime rotary files (Dentsply Sirona). Pre- and postinstrumentation scans were performed at the same position using CBCT to evaluate CT and CA at three levels 3 mm, 6 mm, and 9 mm from the apex and were compared using CBCT software (On Demand 3D software). Statistical Analysis Used: The two groups were statistically analyzed with Mann–Whitney U -test. Results: There was no significant difference among the tested groups regarding the canal centering ratio ( P > 0.05). At 6- and 9-mm levels, there was no significant difference in CT among the two groups ( P > 0.05). However, at 3 mm from apex, there was a statistically significant difference ( P = 0.006) with TN files exhibiting lesser CT. Conclusion: Both the file systems respected the canal anatomy, although in the apical third, TN files exhibited better results. Hence, this file system can be considered for instrumentation of canals with moderate apical curvatures. In regard to CA, no significant differences were found among the file systems.
HyFlex CM和TruNatomy旋转文件系统在适度弯曲根管中CBCT的根管运输和定心能力:一项体外研究
摘要目的:本研究的目的是评估和比较HyFlex CM (HCM)和TruNatomy (TN)旋转文件系统在锥形束计算机断层扫描(CBCT)的帮助下制备的弯曲管的管道运输(CT)和对中能力(CA)。材料与方法:选取10°~ 30°曲率的单根下颌前磨牙40颗,分为两组。组1用HCM锉(Coltene Whaledent)制备根管,组2用TN Prime旋转锉(Dentsply Sirona)制备根管。在同一位置使用CBCT进行仪器前和仪器后扫描,以评估距离尖端3mm, 6mm和9mm三个水平的CT和CA,并使用CBCT软件(随需应变3D软件)进行比较。统计学分析方法:两组采用Mann-Whitney U检验进行统计学分析。结果:两组间根管对中率(P >0.05)。在6毫米和9毫米水平,两组CT无显著差异(P >0.05)。然而,在距尖端3mm处,TN锉表现出较小的CT,差异有统计学意义(P = 0.006)。结论:两种文件系统都尊重根管解剖,但在根尖三分之一,TN文件表现出更好的效果。因此,该文件系统可用于中等根尖曲率的根管内固定。关于CA,在文件系统之间没有发现明显的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Endodontology
Endodontology Medicine-Anatomy
CiteScore
0.60
自引率
0.00%
发文量
0
审稿时长
28 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信