The Surface Plate Calibration Comparison Based on The Grid Method

Q2 Environmental Science
Evergreen Pub Date : 2023-09-01 DOI:10.5109/7151731
Asep Hapiddin, Okasatria Novyanto, None A. Praba Drijarkara, Muhammad Azzumar, Mohamad Syahadi, Miftahul Munir, None Ninuk Ragil Prasasti, None Nur Tjahyo Eka Darmayanti, Budhy Basuki, Hidayat Wiriadinata
{"title":"The Surface Plate Calibration Comparison Based on The Grid Method","authors":"Asep Hapiddin, Okasatria Novyanto, None A. Praba Drijarkara, Muhammad Azzumar, Mohamad Syahadi, Miftahul Munir, None Ninuk Ragil Prasasti, None Nur Tjahyo Eka Darmayanti, Budhy Basuki, Hidayat Wiriadinata","doi":"10.5109/7151731","DOIUrl":null,"url":null,"abstract":": The surface plate is a physical flatness reference that widely used in research and industrial applications, e.g., manufacturing, aerospace, automotive, and shipping engineering. Surface plate calibration is required; as a result to guarantee that it continues to fall within the parameters of what is considered to be an acceptable level of flatness. In most cases, Union Jack Moody’s approach is relied on to gather data and determine the level of flatness and the Grid method is not widely recognized. The Grid technique can be broken down into two patterns: the Open Grid and the Full Grid. Spreadsheet application is utilized to processing flatness data with the Open Grid approach. A piece of computer software, e.g., Scilab or another program that can perform calculations with matrices, is required. Unlike the Open Grid technique, which has a greater degree of uncertainty, the Full Grid technique has a reduced degree of uncertainty. This study aims to report on assessing the surface plate flatness using two different types of Grid techniques. A surface plate measuring 1000 mm×1000 mm, as one of the measurement samples, was used to characterize both approaches. Open Grid and Full Grid measured the surface plate's flatness to be (6.93 ± 3.94) μm and (6.44 ± 0.68) μm, with Full Grid measurin g it more accurately than Open Grid. It is consistently statistically shown that the E n value is less than 1, which is 0.06 and 0.01, respectively. In conclusion, it can be said that statistically, the Full Grid method, as one of the proposed surface plate calibration methods, is considered an inlier result with smaller uncertainty.","PeriodicalId":12085,"journal":{"name":"Evergreen","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Evergreen","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5109/7151731","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 0

Abstract

: The surface plate is a physical flatness reference that widely used in research and industrial applications, e.g., manufacturing, aerospace, automotive, and shipping engineering. Surface plate calibration is required; as a result to guarantee that it continues to fall within the parameters of what is considered to be an acceptable level of flatness. In most cases, Union Jack Moody’s approach is relied on to gather data and determine the level of flatness and the Grid method is not widely recognized. The Grid technique can be broken down into two patterns: the Open Grid and the Full Grid. Spreadsheet application is utilized to processing flatness data with the Open Grid approach. A piece of computer software, e.g., Scilab or another program that can perform calculations with matrices, is required. Unlike the Open Grid technique, which has a greater degree of uncertainty, the Full Grid technique has a reduced degree of uncertainty. This study aims to report on assessing the surface plate flatness using two different types of Grid techniques. A surface plate measuring 1000 mm×1000 mm, as one of the measurement samples, was used to characterize both approaches. Open Grid and Full Grid measured the surface plate's flatness to be (6.93 ± 3.94) μm and (6.44 ± 0.68) μm, with Full Grid measurin g it more accurately than Open Grid. It is consistently statistically shown that the E n value is less than 1, which is 0.06 and 0.01, respectively. In conclusion, it can be said that statistically, the Full Grid method, as one of the proposed surface plate calibration methods, is considered an inlier result with smaller uncertainty.
基于网格法的曲面板标定比较
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Evergreen
Evergreen Environmental Science-Management, Monitoring, Policy and Law
CiteScore
4.30
自引率
0.00%
发文量
99
期刊介绍: “Evergreen - Joint Journal of Novel Carbon Resource Sciences & Green Asia Strategy” is a refereed international open access online journal, serving researchers in academic and research organizations and all practitioners in the science and technology to contribute to the realization of Green Asia where ecology and economic growth coexist. The scope of the journal involves the aspects of science, technology, economic and social science. Namely, Novel Carbon Resource Sciences, Green Asia Strategy, and other fields related to Asian environment should be included in this journal. The journal aims to contribute to resolve or mitigate the global and local problems in Asia by bringing together new ideas and developments. The editors welcome good quality contributions from all over the Asia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信