Seismic Responses of Concrete Building Subjected to Out-of-phase Ground Motions

Yohanes Karyanto, Dario Rosidi, Pamuda Pudjisuryadi
{"title":"Seismic Responses of Concrete Building Subjected to Out-of-phase Ground Motions","authors":"Yohanes Karyanto, Dario Rosidi, Pamuda Pudjisuryadi","doi":"10.9744/ced.25.2.96-105","DOIUrl":null,"url":null,"abstract":"Seismic performance of a building is commonly evaluated by applying same design ground motions at each building foundation. However, local soil conditions beneath a building likely vary, and these variations could result in out-of-phased design ground motions at each of the foundation locations. In this study, building’s responses during earthquakes were analyzed and compared using same and out-of-phase ground motions. The building is 10-story, 90m-wide, reinforced concrete structure supported on isolated footings with tie beams. Dynamic time response analyses were performed using five earthquake records which were scaled to a design response spectrum for a location in Surabaya. Seismic modification factor, R, of 8 was used. The results indicate that the use of out-of-phase ground motions does not have significant impacts on building inter-story drifts; it results, however in significantly higher column base shears and tie beam axial forces compared to those calculated using same ground motions.","PeriodicalId":30107,"journal":{"name":"Civil Engineering Dimension","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Civil Engineering Dimension","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9744/ced.25.2.96-105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Seismic performance of a building is commonly evaluated by applying same design ground motions at each building foundation. However, local soil conditions beneath a building likely vary, and these variations could result in out-of-phased design ground motions at each of the foundation locations. In this study, building’s responses during earthquakes were analyzed and compared using same and out-of-phase ground motions. The building is 10-story, 90m-wide, reinforced concrete structure supported on isolated footings with tie beams. Dynamic time response analyses were performed using five earthquake records which were scaled to a design response spectrum for a location in Surabaya. Seismic modification factor, R, of 8 was used. The results indicate that the use of out-of-phase ground motions does not have significant impacts on building inter-story drifts; it results, however in significantly higher column base shears and tie beam axial forces compared to those calculated using same ground motions.
非相地震动作用下混凝土建筑物的地震反应
建筑物的抗震性能通常是通过在每个建筑物基础上应用相同的设计地震动来评估的。然而,建筑物下面的当地土壤条件可能会有所不同,这些变化可能会导致每个基础位置的非同步设计地面运动。在本研究中,建筑物在地震中的反应分析和比较使用相同和非相地震动。该建筑为10层,90米宽,钢筋混凝土结构,由绑带梁支撑的孤立基座支撑。动态时间响应分析使用五个地震记录进行,这些记录被缩放到泗水一个位置的设计响应谱。地震修正系数R为8。结果表明:利用非相地震动对建筑物层间漂移没有显著影响;然而,与使用相同地面运动计算的结果相比,其结果是柱底剪力和束梁轴力明显更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
15
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信