Simultaneous Analysis of Trace Tetracyclines Antibiotics in Wastewater with Ultra-high Performance Liquid Chromatography Coupled with Mass Spectrometry
{"title":"Simultaneous Analysis of Trace Tetracyclines Antibiotics in Wastewater with Ultra-high Performance Liquid Chromatography Coupled with Mass Spectrometry","authors":"Hua Wang","doi":"10.9734/jpri/2023/v35i277441","DOIUrl":null,"url":null,"abstract":"A comprehensive method was developed for determination of tetracycline, oxytetracycline, chlortetracycline, and doxycycline in wastewater. Based on ultra-high performance liquid chromatography coupled with mass spectrometry (UHPLC–MS), the developed method was specific, sensitive, precise, and accurate. Specificity was confirmed with both retention time and accurate m/z value of four antibiotics. Good linearity was achieved for all compounds in the range 5-100 ng/mL. Repeatability of method was proved. The intra-day and inter-day precision were satisfied. The limit of detection and limit of quantification was low enough at several ng/mL. Recoveries were between 95% and 104% at three concentration levels. The concrete sample collected in local swine farm was determined to containing 15 ng/mL oxytetracycline. The developed method provides a reliable and robust tool that can be used for routine analysis of tetracyclines antibiotics in aqueous samples.","PeriodicalId":16718,"journal":{"name":"Journal of Pharmaceutical Research International","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmaceutical Research International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/jpri/2023/v35i277441","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A comprehensive method was developed for determination of tetracycline, oxytetracycline, chlortetracycline, and doxycycline in wastewater. Based on ultra-high performance liquid chromatography coupled with mass spectrometry (UHPLC–MS), the developed method was specific, sensitive, precise, and accurate. Specificity was confirmed with both retention time and accurate m/z value of four antibiotics. Good linearity was achieved for all compounds in the range 5-100 ng/mL. Repeatability of method was proved. The intra-day and inter-day precision were satisfied. The limit of detection and limit of quantification was low enough at several ng/mL. Recoveries were between 95% and 104% at three concentration levels. The concrete sample collected in local swine farm was determined to containing 15 ng/mL oxytetracycline. The developed method provides a reliable and robust tool that can be used for routine analysis of tetracyclines antibiotics in aqueous samples.