{"title":"Comparison of the immunoassay method with the commercial and in-house LC-MS/MS methods for substance abuse in urine","authors":"Gamze Avcioglu, Gulsen Yilmaz, Safak Yalcin Sahiner, L. Didem Kozaci, Ceylan Bal, Fatma Meric Yilmaz","doi":"10.1515/tjb-2022-0286","DOIUrl":null,"url":null,"abstract":"Abstract Objectives The aim of this study was to compare the analytical performance of the KIMS (kinetic interaction of microparticles in solution) immunochemical method with a validated in-house and a commercial LC-MS/MS method. Methods The urine samples of the 100 subjects were included in the present study. The urine samples were analysed with Roche DAT immunochemical method based on KIMS method. In-house LC-MS/MS method was validated for 58 parameters according to the CLSI C62-A recommendations with the following parameters: matrix effect, lower limit of quantification (LLOQ), linearity, intra-day and inter-day precision and accuracy. Eureka Lab Division Drugs of Abuse kit was used as the commercial LC-MS/MS method. Results The immunochemical method had a satisfactory performance with specificity, sensitivity and accuracy values above 80 % and met the DRUID recommendation except benzodiazepines. The sensitivity and specificity of the immunochemical method were between 97–100 % and 84–100 %, respectively (except for benzodiazepines). The bias obtained for THC-COOH, morphine and codeine parameters were −17.5, 24.6 and 43.6 between two LC-MS/MS methods. The commercial method had a tendency to have a negative bias except for cannabinoids. Conclusions The analytical performance of the KIMS-based urine immunochemical method was found to be satisfactory for the intended use, except for benzodiazepines. The validated urine in-house LC-MS/MS method was found to be a good alternative for confirmation of substance abuse.","PeriodicalId":92463,"journal":{"name":"Turk biyokimya dergisi = Turkish journal of biochemistry","volume":"10 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turk biyokimya dergisi = Turkish journal of biochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/tjb-2022-0286","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Objectives The aim of this study was to compare the analytical performance of the KIMS (kinetic interaction of microparticles in solution) immunochemical method with a validated in-house and a commercial LC-MS/MS method. Methods The urine samples of the 100 subjects were included in the present study. The urine samples were analysed with Roche DAT immunochemical method based on KIMS method. In-house LC-MS/MS method was validated for 58 parameters according to the CLSI C62-A recommendations with the following parameters: matrix effect, lower limit of quantification (LLOQ), linearity, intra-day and inter-day precision and accuracy. Eureka Lab Division Drugs of Abuse kit was used as the commercial LC-MS/MS method. Results The immunochemical method had a satisfactory performance with specificity, sensitivity and accuracy values above 80 % and met the DRUID recommendation except benzodiazepines. The sensitivity and specificity of the immunochemical method were between 97–100 % and 84–100 %, respectively (except for benzodiazepines). The bias obtained for THC-COOH, morphine and codeine parameters were −17.5, 24.6 and 43.6 between two LC-MS/MS methods. The commercial method had a tendency to have a negative bias except for cannabinoids. Conclusions The analytical performance of the KIMS-based urine immunochemical method was found to be satisfactory for the intended use, except for benzodiazepines. The validated urine in-house LC-MS/MS method was found to be a good alternative for confirmation of substance abuse.
免疫分析法与市售和内部LC-MS/MS方法检测尿液中药物滥用的比较
摘要目的本研究的目的是比较KIMS(溶液中微粒的动力学相互作用)免疫化学方法与经过验证的内部和商业LC-MS/MS方法的分析性能。方法收集100例患者的尿液样本。采用Roche DAT免疫化学方法对尿样进行分析。根据CLSI C62-A推荐标准,对内部LC-MS/MS方法进行了58个参数的验证,参数包括:矩阵效应、定量下限(LLOQ)、线性度、日内、日间精密度和准确度。使用Eureka Lab Division Drugs of Abuse试剂盒作为商业LC-MS/MS方法。结果除苯二氮卓类药物外,免疫化学方法的特异性、敏感性和准确度均在80%以上,符合DRUID推荐标准。免疫化学方法的敏感性和特异性分别为97 - 100%和84 - 100%(苯二氮卓类药物除外)。两种LC-MS/MS方法对THC-COOH、吗啡和可待因参数的偏差分别为- 17.5、24.6和43.6。除大麻素外,商业方法倾向于产生负面偏见。结论除苯二氮卓类药物外,基于kims的尿液免疫化学方法的分析性能令人满意。经验证的尿液内部LC-MS/MS方法是确认药物滥用的一个很好的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信