医療用6 MeVと10 MeVリニアック施設の免震層実効線量評価法

Q4 Engineering
Takuma NOTO, Kazuaki KOSAKO
{"title":"医療用6 MeVと10 MeVリニアック施設の免震層実効線量評価法","authors":"Takuma NOTO, Kazuaki KOSAKO","doi":"10.3327/taesj.j22.020","DOIUrl":null,"url":null,"abstract":"The widespread use of medical linacs for cancer treatment and seismic isolation structures in Japan led to the construction of an increasing number of buildings in which medical linac rooms are located directly above the seismic isolation layer. Extending the control area in the seismic isolation layer is advantageous for reducing the cost of floor shielding. However, establishing a simple calculation method is necessary to evaluate the effective dose in the seismic isolation layer for shielding design. We proposed and verified a simple calculation method that can be applied to evaluate the effective dose in the seismic isolation layer of 10 MeV linac facilities. The parameters of the method were investigated when applied to 6 and 10 MeV linacs and extensively validated by comparing the results with the Monte Carlo calculation. For the seismic isolation layer in which the height of the space is ≤2 m, the results of the method and the Monte Carlo calculation agree within 28% and 21% at points of half-height and ≥3 m horizontally from the linac source, respectively. Furthermore, the measured doses were compared with the proposed method values in the seismic isolation layer of a 10 MeV linac facility.","PeriodicalId":55893,"journal":{"name":"Transactions of the Atomic Energy Society of Japan","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the Atomic Energy Society of Japan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3327/taesj.j22.020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

The widespread use of medical linacs for cancer treatment and seismic isolation structures in Japan led to the construction of an increasing number of buildings in which medical linac rooms are located directly above the seismic isolation layer. Extending the control area in the seismic isolation layer is advantageous for reducing the cost of floor shielding. However, establishing a simple calculation method is necessary to evaluate the effective dose in the seismic isolation layer for shielding design. We proposed and verified a simple calculation method that can be applied to evaluate the effective dose in the seismic isolation layer of 10 MeV linac facilities. The parameters of the method were investigated when applied to 6 and 10 MeV linacs and extensively validated by comparing the results with the Monte Carlo calculation. For the seismic isolation layer in which the height of the space is ≤2 m, the results of the method and the Monte Carlo calculation agree within 28% and 21% at points of half-height and ≥3 m horizontally from the linac source, respectively. Furthermore, the measured doses were compared with the proposed method values in the seismic isolation layer of a 10 MeV linac facility.
医用6mev和10mev线性设施的防震层有效剂量评估法
在日本,医疗直线室广泛用于癌症治疗和隔震结构,导致越来越多的建筑物将医疗直线室直接设在隔震层的上方。扩大隔震层控制面积有利于降低楼板屏蔽成本。然而,建立一种简单的计算方法来评估隔震层的有效剂量是进行屏蔽设计的必要条件。提出并验证了一种简便的计算方法,可用于评价10 MeV直线加速器设施隔震层的有效剂量。将该方法应用于6 MeV和10 MeV的直线加速器上进行了参数研究,并与蒙特卡罗计算结果进行了比较。对于空间高度≤2 m的隔震层,在距直线震源半高和距直线震源水平≥3 m处,该方法计算结果与蒙特卡罗计算结果的一致性分别在28%和21%以内。此外,在一个10 MeV直线加速器设施的隔震层中,将测量到的剂量与提出的方法值进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Transactions of the Atomic Energy Society of Japan
Transactions of the Atomic Energy Society of Japan Energy-Nuclear Energy and Engineering
CiteScore
0.50
自引率
0.00%
发文量
16
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信