Comparative Evaluation of Apical Debris Extrusion During Root Canal Preparation Using Two Different Rotary File Systems: “A Wave One Gold and Hyflex EDM Rotary File Comparison”

Hammad Athar
{"title":"Comparative Evaluation of Apical Debris Extrusion During Root Canal Preparation Using Two Different Rotary File Systems: “A Wave One Gold and Hyflex EDM Rotary File Comparison”","authors":"Hammad Athar","doi":"10.58624/svoade.2023.04.0149","DOIUrl":null,"url":null,"abstract":"Background: Apically extruded debris following root canal treatment leads to postoperative complications like inflammation, postoperative pain, and delay in periapical healing. Additionally, debris extruded during treatment is responsible for persistent apical area inflammation. Hence, a decrease in debris extrusion is necessary for reduction in postoperative complications. Aim: Two distinct instrumentation methods were used to measure the amount of apically extruded debris after root canal preparation in the present study. Materials and Method: Idea was to include thirty extracted single rooted human premolar teeth for study purpose. After access opening, canal patency was established using a 15 K-file till the apical foramen then it is to be followed by determination of working length by visual method. The samples were divided into 2 groups: Group1: Wave One gold. Group 2: Hyflex EDM Rotary file. The manufacturer’s instructions were followed for the instrumentation. During instrumentation, extruded debris and irrigants were collected into the preweighed test tubes. Following this, these tubes were stored in an incubator at the temperature of 70°C for the next 5 days. To assess the resultant weight of extruded debris, the test tubes were weighed. The final mass of the extruded debris was calculated by subtracting the weight of the initial empty vial from vial containing dry debris. Result: According to the results obtained in this study, both the tested files caused extrusion of debris apically. The h debris extrusion in Hyflex EDM system was reported to be highest, whereas WaveOne Gold showed the lowest value. Conclusion: Result of this study showed that Waveone gold was associated with less debris extrusion in comparison to hyflex EDM rotary file.","PeriodicalId":93501,"journal":{"name":"SVOA Dentistry","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SVOA Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.58624/svoade.2023.04.0149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Apically extruded debris following root canal treatment leads to postoperative complications like inflammation, postoperative pain, and delay in periapical healing. Additionally, debris extruded during treatment is responsible for persistent apical area inflammation. Hence, a decrease in debris extrusion is necessary for reduction in postoperative complications. Aim: Two distinct instrumentation methods were used to measure the amount of apically extruded debris after root canal preparation in the present study. Materials and Method: Idea was to include thirty extracted single rooted human premolar teeth for study purpose. After access opening, canal patency was established using a 15 K-file till the apical foramen then it is to be followed by determination of working length by visual method. The samples were divided into 2 groups: Group1: Wave One gold. Group 2: Hyflex EDM Rotary file. The manufacturer’s instructions were followed for the instrumentation. During instrumentation, extruded debris and irrigants were collected into the preweighed test tubes. Following this, these tubes were stored in an incubator at the temperature of 70°C for the next 5 days. To assess the resultant weight of extruded debris, the test tubes were weighed. The final mass of the extruded debris was calculated by subtracting the weight of the initial empty vial from vial containing dry debris. Result: According to the results obtained in this study, both the tested files caused extrusion of debris apically. The h debris extrusion in Hyflex EDM system was reported to be highest, whereas WaveOne Gold showed the lowest value. Conclusion: Result of this study showed that Waveone gold was associated with less debris extrusion in comparison to hyflex EDM rotary file.
两种不同旋转锉系统对根管预备过程中根尖碎片挤压的比较评价:“A Wave One Gold和Hyflex EDM旋转锉的比较”
背景:根管治疗后根尖挤压碎片会导致术后并发症,如炎症、术后疼痛和根尖周愈合延迟。此外,治疗过程中挤出的碎片是造成持续的根尖区炎症的原因。因此,减少碎片挤压对于减少术后并发症是必要的。目的:本研究采用两种不同的测量方法来测量根管预备后根尖挤压碎片的数量。材料与方法:拟纳入30颗拔除的单根人前磨牙作为研究对象。通道打开后,用15k锉建立根管通畅,直至根尖孔,然后用目测法确定工作长度。将样品分为两组:第一组:波一金。第二组:Hyflex EDM旋转文件。仪器的使用遵循了制造商的说明。在仪器过程中,挤压的碎片和冲洗剂被收集到预称重的试管中。在此之后,这些试管在70°C的温度下储存在培养箱中5天。为了评估挤压碎片的最终重量,对试管进行了称重。挤出碎片的最终质量是通过从含有干碎片的小瓶中减去初始空瓶的重量来计算的。结果:根据本研究的结果,两种试验锉均引起尖部碎片的挤压。据报道,Hyflex EDM系统的碎屑挤压率最高,而WaveOne Gold系统的碎屑挤压率最低。结论:与hyflex EDM旋转锉相比,Waveone gold具有更少的碎片挤压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信