{"title":"Research and Development of Zero-Point Detector of Catheter and Its Clinical Application Effects","authors":"Huiting Kuo, Meili Shen, Yating Ke","doi":"10.35745/ijcmb2023v03.01.0001","DOIUrl":null,"url":null,"abstract":"Patients in intensive care units often need to use various catheters to monitor their physiological conditions. The caregiver connected the invasive catheter and pressure transmission line to the physiological monitor. For the intensive and continuous monitoring of hemodynamic changes, the measured physiological data is used for medical judgment and treatment. However, in the current clinical situation, nurses do not have consistent horizontal calibration tools or equipment, and the reliability and accuracy of the data obtained by physiological monitors need to be confirmed. Different conduits need to be matched with the fixing seats provided by the original factory. When catheters of different specifications and types are used together, nurses need to use the fine movements of the hand knob to fix the seat to adjust or replace the fixed seat, which caused potential injuries to the hands. Based on creative ideas from clinical needs, an innovative device was developed. Its fixed base template combined the three major features of “adjustable fixed frame”, “laser light source calibrator” and “electric track”. The fixed base was suitable for catheters of different specifications. The laser light source was used to accurately align the pressure converter vent with the zero point marked outside the patient’s body. The electric track was used to move the fixed base up and down during horizontal calibration. Therefore, it was named “Comprehensive Catheter Zero Point Detector”. The product was tested in clinical trials and information on the relevant application effectiveness was collected. The innovatively developed product was used in three intensive care units. Nearly 90% of nurses believed that the “all-around catheter zero-point detector” achieved accurate measurement and reduced operating errors. Not only did it provide patients with better and more precise care, but the satisfaction of nurses operating the equipment was also greatly improved.: This developed device allowed for the convenience of using measurement tools and precise horizontal positioning. Visual errors between operators were reduced and the accuracy of measurement values was effectively improved.","PeriodicalId":480191,"journal":{"name":"International Journal of Clinical Medicine and Bioengineering","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Clinical Medicine and Bioengineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35745/ijcmb2023v03.01.0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Patients in intensive care units often need to use various catheters to monitor their physiological conditions. The caregiver connected the invasive catheter and pressure transmission line to the physiological monitor. For the intensive and continuous monitoring of hemodynamic changes, the measured physiological data is used for medical judgment and treatment. However, in the current clinical situation, nurses do not have consistent horizontal calibration tools or equipment, and the reliability and accuracy of the data obtained by physiological monitors need to be confirmed. Different conduits need to be matched with the fixing seats provided by the original factory. When catheters of different specifications and types are used together, nurses need to use the fine movements of the hand knob to fix the seat to adjust or replace the fixed seat, which caused potential injuries to the hands. Based on creative ideas from clinical needs, an innovative device was developed. Its fixed base template combined the three major features of “adjustable fixed frame”, “laser light source calibrator” and “electric track”. The fixed base was suitable for catheters of different specifications. The laser light source was used to accurately align the pressure converter vent with the zero point marked outside the patient’s body. The electric track was used to move the fixed base up and down during horizontal calibration. Therefore, it was named “Comprehensive Catheter Zero Point Detector”. The product was tested in clinical trials and information on the relevant application effectiveness was collected. The innovatively developed product was used in three intensive care units. Nearly 90% of nurses believed that the “all-around catheter zero-point detector” achieved accurate measurement and reduced operating errors. Not only did it provide patients with better and more precise care, but the satisfaction of nurses operating the equipment was also greatly improved.: This developed device allowed for the convenience of using measurement tools and precise horizontal positioning. Visual errors between operators were reduced and the accuracy of measurement values was effectively improved.
导管零点检测仪的研究与开发及其临床应用效果
重症监护病房的病人经常需要使用各种导管来监测他们的生理状况。护理人员将有创导管和压力传输线连接到生理监视器上。对于血流动力学变化的密集和连续监测,测量的生理数据用于医学判断和治疗。然而,在目前的临床情况下,护士没有一致的水平校准工具或设备,生理监测仪获得的数据的可靠性和准确性有待证实。不同的管道需要配合原厂提供的固定座。当不同规格和类型的导尿管一起使用时,护士需要使用手旋钮的精细动作来固定座位来调整或更换固定座位,这对手部造成了潜在的伤害。基于临床需求的创造性想法,开发了一种创新装置。其固定底座模板结合了“可调固定架”、“激光光源校准器”和“电动轨道”三大特点。固定底座适用于不同规格的导管。激光光源用于精确对准压力转换器排气口与患者体外标记的零点。在水平校准时,电动轨道用于上下移动固定底座。因此被命名为“综合性导管零点检测仪”。对该产品进行了临床试验,并收集了相关应用效果的信息。创新开发的产品在三个重症监护室使用。近90%的护士认为“全能导尿管零点检测仪”测量准确,减少了操作失误。它不仅为患者提供了更好、更精确的护理,而且大大提高了操作设备的护士的满意度。该装置便于使用测量工具和精确的水平定位。减少了操作者之间的视觉误差,有效地提高了测量值的精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信